Nortel Networks BM450の取扱説明書

102ページ 1.44 mb
ダウンロード

ページに移動 of 102

Summary
  • Nortel Networks BM450 - page 1

    BCM450 Busine ss C ommunic ations Manager Docume nt S tatus: Stan da r d Document Number : NN40160-700 Document V ersion: 01.01 Date: Augu st 2008 BCM4 50 T r oubleshooting Guide ...

  • Nortel Networks BM450 - page 2

    Copyright © 2008 Nor tel Netw orks, All Rights Reserved All rights reserved. The information in this document is subj ect to change without notic e. The statements, configur ations, techni cal data, and recommendations in this document are belie ved to be accurate and re liable, but are presented wi thout express or implied warranty . Users must t ...

  • Nortel Networks BM450 - page 3

    3 BCM450 Troubleshooting Guide Task List Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Initial Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Hardware Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Nortel Networks BM450 - page 4

    4 Task List NN40 16 0-700 Understanding system messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 To set Release Reasons .............. ............. ................ ................. ............ ................. ...... 83 Useful Troubleshooting Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Nortel Networks BM450 - page 5

    5 BCM450 Troubleshooting Guide Contents Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Audience . . . . . . . . . . . . . . . . . . . . . ...

  • Nortel Networks BM450 - page 6

    6 Contents NN40160-700 NN40160-700 Check the p rogramming of lines and phones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Check line pr ogramming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Trunk/Line d ata . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Nortel Networks BM450 - page 7

    Contents 7 BCM450 Troubleshooting Guide Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Command Li ne Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Accessing the CLI . . . . . . . . . . . . . . . . . . ...

  • Nortel Networks BM450 - page 8

    8 Contents NN40160-700 NN40160-700 Chapter 12 Contacting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Gathering crit ical informat ion . . . . . . . . . . . . . . . . . . . . ...

  • Nortel Networks BM450 - page 9

    9 BCM450 Troubleshooting Guide Chapter 1 Introduction The Nortel Business Communications Manager 450 (BCM450) provides private network and telephony management capability to small and medium-sized businesses. The BCM450 system integrates voice and data capab ilities, and IP Telephony gateway fu nctions into a single telephony system. It also enable ...

  • Nortel Networks BM450 - page 10

    10 Chapter 1 Introduct ion NN40160-700 NN40160-700 • Contacting T ech nical Support o n page 99 Acr on yms The following is a list of ac ronyms used in this guide. T abl e 1 List of acronyms Acron ym Description AIS Alar m Indication Signal BCM Business Communicati ons Manager BFT Base Function T r a y BRI Basic Rate Interface CbC Call by Call CD ...

  • Nortel Networks BM450 - page 11

    Chapter 1 Introduction 11 BCM450 Troubleshooting Guide OOF Out of F rame PPP P oint-to -P oint Protocol PRI Primar y Ra te Interface PBX Private Branch Exchange PSTN Public Switched T elephone Ne twork PVQM Proactive V oice Qua lity Monitoring QoS Quality of Ser vice RAI Remote Alarm Indication R TP Real-time T ransport Protocol SFTP Secure File T ...

  • Nortel Networks BM450 - page 12

    12 Chapter 1 Introduct ion NN40160-700 NN40160-700 Symbols and con ventions used in this guide These symbols are used to highlig ht crit ical information for the BCM450 system: Caution: Alerts you to conditions where you can damage the equipment. Danger: Alerts you to conditions where yo u can get an electrical shock. W arning: Alerts you to condit ...

  • Nortel Networks BM450 - page 13

    Chapter 1 Introduction 13 BCM450 Troubleshooting Guide Related publications Related publications are listed below. To locate specific info rmation, you can refer to the Master Index of BCM450 Library (NN40020-100) . BCM450 Administration and Security Gui de (NN40160-601) BCM450 Installation Guide—System (NN40160-301) BCM450 Maintenanc e Guide (NN ...

  • Nortel Networks BM450 - page 14

    14 Chapter 1 Introduct ion NN40160-700 NN40160-700 ...

  • Nortel Networks BM450 - page 15

    15 BCM450 Troubleshooting Guide Chapter 2 Initial Troubleshooting You can better troubles hoot the problems on your netwo rk and reduce their impa ct by preparing for such events in advance. To do this, you must know the following: • that your system is properly installed and routinel y maintained • the conf iguration of your network • the no ...

  • Nortel Networks BM450 - page 16

    16 Chapter 2 Initial Trou bleshooting NN40160-700 NN40160-700 Logical connections You must know how your devic es are connected logically as well as physically. Fo r example, while virtual LANs (VLANs) are not supported on the BCM450 system, VLANs may exist between IP sets connected to the BCM450. Device configuration inf o rmation You should maint ...

  • Nortel Networks BM450 - page 17

    Chapter 2 Initial Troubleshoot ing 17 BCM450 Troubleshooting Guide used to compare against the results that you get when your network is experiencing trouble. For example, ping each node to discover how long it typically takes to receive a response from devices on your network. Capture and save each d evice’s response time and wh en you are troub ...

  • Nortel Networks BM450 - page 18

    18 Chapter 2 Initial Trou bleshooting NN40160-700 NN40160-700 ...

  • Nortel Networks BM450 - page 19

    19 BCM450 Troubleshooting Guide Chapter 3 Hardware Troubleshooting Use the tasks in this chapter to troubleshoot problems related to the BCM450 hardware components. Navigation • T roubleshooting th e BCM450 hardwa re on page 19 • Po wer on self test on page 27 • T esting basic hardware functionality on page 28 • Monitoring the boot process ...

  • Nortel Networks BM450 - page 20

    20 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 System status LEDs The chassis of the BCM450 contains two LEDs: a Status LED and a Power LED. The Power LED is located at the bottom left of the chassis; th e Status LED is immediately above it. The table System status LEDs states and descriptions on pa ge 20 describes the meaning of ...

  • Nortel Networks BM450 - page 21

    Chapter 3 Hardware Tr oubleshooting 21 BCM450 Troubleshooting Guide LAN port LEDs Each LAN port on the main un it and expansion un it has two LEDs. These LEDs indicate the status of the connection for that LAN port. The figure LAN port LED location s on page 21 shows the location of these LED s on the main unit. Figure 1 LAN por t LED locations The ...

  • Nortel Networks BM450 - page 22

    22 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 Figure 2 MBM LEDs The table MBM LED descriptions on page 22 describes the possible MBM LED states. DTM LEDs The DTM has additional LEDs that are not on most other MBMs. The figure DTM LEDs on page 23 shows the location of the DTM LEDs. T able 3 MBM LED des cr iptions P ower Status Des ...

  • Nortel Networks BM450 - page 23

    Chapter 3 Hardware Tr oubleshooting 23 BCM450 Troubleshooting Guide Figure 3 DTM LEDs The table DTM LED functions on page 23 describes the function s of the DTM LEDs. T able 4 DTM LED functions LED Status Descriptions Po w e r – S e e “Media bay module LEDs (e xpansion units only)” for details. Status – See “Media bay module LEDs (e xpans ...

  • Nortel Networks BM450 - page 24

    24 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 BRIM LEDs The BRIM has one ad ditional LED beside each RJ-48C jack. These LEDs are on when the ISDN line is active. The figure BRIM LEDs on page 24 shows the lo cation of the LEDs on a BRIM. Figure 4 BRIM LEDs For more information on the power and status LED functions, see Media bay m ...

  • Nortel Networks BM450 - page 25

    Chapter 3 Hardware Tr oubleshooting 25 BCM450 Troubleshooting Guide 2 Select the System folder and click the Keycodes task. The K eycodes panel displays and the installe d features appear in the Ke ycodes list. 3 T o enter a new k eycode, click Load File . 4 Bro wse to where you saved the ke ycode file you downloaded from KRS. 5 Click Open . The fi ...

  • Nortel Networks BM450 - page 26

    26 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 To restart the system Use this procedure to restart th e system from the Element Manager. 1 Select Administration > Utilities > Reset . 2 Click the appropriate reset b utton. Table 5 lists the Reset functions. T able 5 Reset functions Function Descripti on Impact Reboot BCM450 S ...

  • Nortel Networks BM450 - page 27

    Chapter 3 Hardware Tr oubleshooting 27 BCM450 Troubleshooting Guide To restart the system from the BCM450 hardwa re, use the reset b utton as described in Hardware reset functions on page 27. Note: When you restart the BCM450 system using t he Re set button, the system will wait for 10 seconds for a user to log into the Maintenance CLI. If a user d ...

  • Nortel Networks BM450 - page 28

    28 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 Figure 5 Example: Bootloader .log file with no errors Figure 6 Example: Boot file with errors T esting basic hard ware functionality This section describes how to test the comp onents of the BCM450 system, and how to troubleshoot them if they fail the test. Use the following procedure ...

  • Nortel Networks BM450 - page 29

    Chapter 3 Hardware Tr oubleshooting 29 BCM450 Troubleshooting Guide To test the main unit If you have the digital station feat ure included in your in stalled ke ycode, use the following test to ensure the main unit is operating properly: 1 Go to an extension that is connected to th e RJ-21 telephon y connector on the main unit. 2 Check for a dial ...

  • Nortel Networks BM450 - page 30

    30 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 4 Check for a dial tone. 5 Use this e xtension to make a call to another e xtension on the system. 6 If the expansion unit has an MBM that supports lin es, go to an extension that has access to one of the lines on the MBM. 7 Select the line or line pool to which the line belongs. 8 Ch ...

  • Nortel Networks BM450 - page 31

    Chapter 3 Hardware Tr oubleshooting 31 BCM450 Troubleshooting Guide Go to an e xtension that has access to one of t he lines on the MBM if it is a trunk MBM. Select the line or line p ool to which the line belongs. 3 Check f or a dial tone. 4 Use this e xtension to mak e a call to another e xtension on the system if it is a station MBM. OR Mak e a ...

  • Nortel Networks BM450 - page 32

    32 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 3 Check that the correct feature for digital se ts is included in your installed ke ycode. 4 V erify that the A T A2 is connected to a digital station port. 5 Allo w suff icient startup time (30–60 sec). 6 Plug an analog de vice into the phone port of the A T A2 and check for a dial ...

  • Nortel Networks BM450 - page 33

    Chapter 3 Hardware Tr oubleshooting 33 BCM450 Troubleshooting Guide Figure 7 Reset s witch location Some possible situations in which you use the reset feature are: • If the BCM450 system is configured incorrectly to an extent that it is no longer functional. The customer must use a le vel 1 rese t to return to the def ault sy stem programming an ...

  • Nortel Networks BM450 - page 34

    34 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 Activate the reset feature You activate the reset feature th rough th e Maintenance CLI or the Config uration CLI. When you initiate a reset from the CLI menu, no further actio n is needed to complete the reset. You can monitor the progress of the reset by observing the LE D states, o ...

  • Nortel Networks BM450 - page 35

    Chapter 3 Hardware Tr oubleshooting 35 BCM450 Troubleshooting Guide • data bits: 8 •p a r i t y : N • stop bits: 1 • no flo w control 3 Use a terminal emulation program, such as Hype rterminal or Nortel CLI Manager , to establish a connection to the BCM450. 4 Reboot the system and observ e th e bo ot pro cess. Figure 8 shows an e xample of ...

  • Nortel Networks BM450 - page 36

    36 Chapter 3 Har dware Tr oublesho oting NN40160-700 NN40160-700 Figure 8 Boot proces s w ith failed or missing memor y Figure 9 Boot process with f a iled or missing hard driv e ...

  • Nortel Networks BM450 - page 37

    37 BCM450 Troubleshooting Guide Chapter 4 Software Troubleshooting Use the information in t his chapter to troubles hoot problems related to the BCM450 software components. Navigation Complete the following tasks, in the order show n below, to troubleshoot some of the common problems that you may en co un ter with the BCM450 software: • V erify t ...

  • Nortel Networks BM450 - page 38

    38 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 —T h e Restrictions tabbed panel allows yo u to define which restrictions will be active for individual lines. Note that lines that are assi gned to the same line po ol will automatically assign the same restrictions. —T h e Assigned DNs tabbed panel provides a quick way to assign l ...

  • Nortel Networks BM450 - page 39

    Chapter 4 Software Troub leshooting 39 BCM450 Troubleshooting Guide Trunk Type PSTN-bas ed lines, VoIP, Target There are three main cate go rie s of lines: PSTN-based lines: ( analog, T1, PRI, BRI) Voice over IP (VoIP) tr unks, which connect t hrough the LAN or WAN. Target lines, which are internal chann els that pr ovide dir ect dial capability. N ...

  • Nortel Networks BM450 - page 40

    40 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 Pr operties The Properties tab shows basic line properties. Not all fields apply to all types of l ines. The Propert ies tab is shown in Figure 10 on page 41 . Pub. Received # (Target lines only) <digits asso ciated with a specific target line> Specify the digits the system w ill ...

  • Nortel Networks BM450 - page 41

    Chapter 4 Software Troub leshooting 41 BCM450 Troubleshooting Guide Figure 10 Proper ties details panel Table 8 on page 41 defines the fields on this panel and indicates the lines. T able 8 Proper ties line setting s (Sheet 1 of 2) Attribute V alue Description Legend: Loop = analog/digital loop ; GS = gr ound st art; DID = DID; E&M = E&M; B ...

  • Nortel Networks BM450 - page 42

    42 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 Preferences The Preferences tab shows informatio n that may vary from trunk to tr unk. Most of this information needs to coord inate with the line service provider equipment. The Preferences tab is shown in Fi gure 11. Figure 11 Pref erences det ails panel Signaling DID E&M WinkSt a ...

  • Nortel Networks BM450 - page 43

    Chapter 4 Software Troub leshooting 43 BCM450 Troubleshooting Guide Table 9 defines the fields on th is panel and indicates the lines. T able 9 Pref erences details fields f or lines (Sheet 1 of 3) Attribute V alue Description Legend: Loop = analog/digital loop; GS = gr ound start; DID = DID; E&M = E&M; BRI = BRI; DPNSS = DPNSS; V oIP = V o ...

  • Nortel Networks BM450 - page 44

    44 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 Answer mode Loop GS E&M BRI DPNSS Manual Auto Define whether a t runk is manual or automatic answer. Auto answer mode allows the trunk to be a shared resource by the system telephones. This shared resource is created through routing to target lines or using DISA. For auto answer tr ...

  • Nortel Networks BM450 - page 45

    Chapter 4 Software Troub leshooting 45 BCM450 Troubleshooting Guide Restrictions Assigning Line restrictions and Re mote Acces s Package restrictio ns are part of the configuratio n for controlling calls out of the system (line restri ctions) and into the syst em from a private network node or from a remote user calling in over the PSTN lines (Remo ...

  • Nortel Networks BM450 - page 46

    46 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 Assigned DNs The Assig ned DNs tabbed panel displays the DN properties for lines that are assigned to telephones. This information can also be configured on th e DN record . Any information added, deleted o r modified in this table re flects in the DN record. Restoring system data If th ...

  • Nortel Networks BM450 - page 47

    Chapter 4 Software Troub leshooting 47 BCM450 Troubleshooting Guide 5 Select the optional componen ts that you want to include from the backup f il e. 6 Click the OK button. A warning windo w opens and displays information about components that will be af fected by the restore operation. Read the wa rning carefully before proceeding. 7 Click the Ye ...

  • Nortel Networks BM450 - page 48

    48 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 V erify the software in ventory This section provides information about how to verify the level of software components and obtain updates to your software inven tory. For informa tion about applying software updates, please refer to the BCM450 Administration and Security Guide (NN40160- ...

  • Nortel Networks BM450 - page 49

    Chapter 4 Software Troub leshooting 49 BCM450 Troubleshooting Guide To obtain updates from the Nor tel Technical Support Web page 1 In your web bro wser , enter www .nortel.com/cs and then click the Go b utton. The Nortel T echnical Support W eb page opens. 2 Do wnload the required updates. 3 Create a directory for each update and unzi p the downlo ...

  • Nortel Networks BM450 - page 50

    50 Chapter 4 Software Tr oubleshooting NN40160-700 NN40160-700 ...

  • Nortel Networks BM450 - page 51

    51 BCM450 Troubleshooting Guide Chapter 5 Advanced Troubleshooting This chapter contains examples of advanced tr oubleshooting pr oc edures. You m ust b e a system administrator to perform these procedures. Navigation • Example 1: Cannot d ial out from an analog trunk on page 51 • Example 2: Cannot d ial out from a SIP or H323 VoIP trunk on pag ...

  • Nortel Networks BM450 - page 52

    52 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 6 Select Conf iguration > T elephony > Lines > Activ e Physical Lines. Select the appropriate line and v erify that it is provis ioned correctly . The Line T ype should be Pool A, the T runk Mode should be Supervised , and the Dial Mode should be T one. 7 Select Conf iguration ...

  • Nortel Networks BM450 - page 53

    Chapter 5 Advanced Troub leshooting 53 BCM450 Troubleshooting Guide 9 Select the BCM Inf o tab and verify the status of the line. Example 2: Cannot dial out fr om a SIP or H323 V oIP trunk When you cannot dial out from a SIP or H323 Vo IP trunk, you may experience t he following problems in your n etwork: • you are unable to reach a destination n ...

  • Nortel Networks BM450 - page 54

    54 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 3 V erify that the appropriate keycode is acti ve. F or H323 trunks, the keycode is Vo I P G W Tr u n k , and for SIP trunks, the keycode is SIP GW T runk . 4 Select Conf iguration > T elephony > Lines > Activ e V oIP Lines. Select the appropriate line and verify that the Contr ...

  • Nortel Networks BM450 - page 55

    Chapter 5 Advanced Troub leshooting 55 BCM450 Troubleshooting Guide 6 Click the Add button to open the Add Remote Gateway dialog box. V erify that the remote gate way is conf igured correctly . 7 Select Conf iguration > T elephony > Dialing Plan > Routing and select the Routes tab . V erify that the route is configured correctly . 8 Select ...

  • Nortel Networks BM450 - page 56

    56 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 Note: Ensure that the Absorbed Length is configured to the expected dialing plan. 9 Select Conf iguration > T elephony > Sets > Active Sets and select the Line Access tab . ...

  • Nortel Networks BM450 - page 57

    Chapter 5 Advanced Troub leshooting 57 BCM450 Troubleshooting Guide 10 Highlight the appropriat e set and select the Line P ool Access tab . V erify that the set has access to V oIP trunks 11 Select Conf iguration > T elephony > Dialing Plan > Pri vate Netw ork and ensure that the Private Netw ork T y pe is set to CDP or UDP . ...

  • Nortel Networks BM450 - page 58

    58 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 Note: In this example, the dialing pl an is configured for a CDP Netw ork with the recomm ended minim um 4 digit Private DN length Example 3: IP set is not registering with the BCM450 When an IP set can not register with the BCM450, you may notice the following problem in your network: ...

  • Nortel Networks BM450 - page 59

    Chapter 5 Advanced Troub leshooting 59 BCM450 Troubleshooting Guide If the number of phones connected does not exceed the number of licenses, and does not exceed the maxium number of IP sets su pp orted, use the proce dure Troubleshooting e xample 3b on page 59 to verify the config uration of the IP phone. Troubleshooting example 3a 1 Select Conf i ...

  • Nortel Networks BM450 - page 60

    60 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 4 V erify S1/S2 IP address & Port settin gs on phone (Port 7000 for BCM) Example 4: Cannot install ke ycode or in valid ke ycode application When you cannot install a keycod e, or have an invalid keycod e application, you will see the following message: “Erro r Happened. Error det ...

  • Nortel Networks BM450 - page 61

    Chapter 5 Advanced Troub leshooting 61 BCM450 Troubleshooting Guide Troubleshooting example 4 1 V erify that the ke ycode is generated against the right system ID in the Ke ycode Retrie v al System (KRS). Access the KRS using one of the follo wing methods: a Connect to http://www .nortel.com/support/tools/krs/ b In Element Manager , select Conf igu ...

  • Nortel Networks BM450 - page 62

    62 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 Troubleshooting example 5 1 Check that the LED indicators on the BCM Chassis are solid green. 2 V erify the physical connection from the carrier demarcation; ensure that the cable is securely connected. 3 V erify the physical connection from the ca rrier demarcation to the BCM450 equipm ...

  • Nortel Networks BM450 - page 63

    Chapter 5 Advanced Troub leshooting 63 BCM450 Troubleshooting Guide 7 Select the Pro vision Lines tab and verify that the lines are correctl y provisioned. 8 Select Conf iguration > T elephony > Dialing Plan > Routing and select the Routes tab . V erify that the route is configured correctly 9 Select Conf iguration > T elephony > Dia ...

  • Nortel Networks BM450 - page 64

    64 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 Note: Ensure that the Absorbed Length is configured to the expected dialing plan. 10 Select Administration > T elephony Metrics > T runk Module Metrics and select the DTM module. V erify that the State of the DTM module is Enabled. 11 Select the CSU Alarm History tab and check the ...

  • Nortel Networks BM450 - page 65

    Chapter 5 Advanced Troub leshooting 65 BCM450 Troubleshooting Guide 12 Select Ad ministration > T elephony Metrics > CBC Limit Metrics and verify calls were not denied due to exceeding CBC limits. 13 Select Administration > Utilities > BCM Monitor and click the Laun ch BCM Monitor bu tton. ...

  • Nortel Networks BM450 - page 66

    66 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 14 Select the Line Monitor tab and verify the status of the line; sel ect the UIP tab and verify the call set up. Example 6: MeetMe Conferencing commands do not w ork, or conferencing is b usy Use the following procedure to trouble shoot problems with MeetMe Conferenc ing. ...

  • Nortel Networks BM450 - page 67

    Chapter 5 Advanced Troub leshooting 67 BCM450 Troubleshooting Guide Troubleshooting example 6 1 Select Configuration > Resour ce s > A pplication Resour ces and select the V o iceMail + CC application. 2 Increase the maximum nu mber of application resourc es (voice ports) for V oice Mail + CC. Example 7: Unable to appl y a software update fr ...

  • Nortel Networks BM450 - page 68

    68 Chapter 5 Advanced Trouble shooting NN40160-700 NN40160-700 Example 8: Element Manager incorrectl y shows e xpansion cabinet as empty Use the following procedure when a module is installed in the ex pansio n cabinet, but the Element Manager shows the expansion cabinet as empty, and the MBM is not active. 1 Select Conf igu ration > Resources & ...

  • Nortel Networks BM450 - page 69

    69 BCM450 Troubleshooting Guide Chapter 6 Recovery trees The chapter provides recovery trees for common troubleshooting scenarios. Navigation • System is not processing calls on page 69 • Start-up profile fails on page 70 • Cannot access BCM450 through Element Manager on page 71 • BCM450 shuts down un expectedly on page 73 System is not pr ...

  • Nortel Networks BM450 - page 70

    70 Chapter 6 Recovery t rees NN40160-700 NN40160-700 Figure 12 System is not processing ca lls Star t-up pr ofile fails Use the following flowchart when the start-up profile of the BCM450 fails. ...

  • Nortel Networks BM450 - page 71

    Chapter 6 Recovery tr ees 71 BCM450 Troubleshooting Guide Figure 13 Star t-up profile fails Cannot access BCM450 thr ough Element Manager Use the following flowchart wh en you cannot ac cess the BCM450 through Element Manager. ...

  • Nortel Networks BM450 - page 72

    72 Chapter 6 Recovery t rees NN40160-700 NN40160-700 Figure 14 Cannot access BCM450 through Element Manage r ...

  • Nortel Networks BM450 - page 73

    Chapter 6 Recovery tr ees 73 BCM450 Troubleshooting Guide BCM450 shuts down une xpectedly Use the following flowchart when th e BCM450 sh uts down unexpectedly. Figure 15 Une xpected shutdown ...

  • Nortel Networks BM450 - page 74

    74 Chapter 6 Recovery t rees NN40160-700 NN40160-700 ...

  • Nortel Networks BM450 - page 75

    75 BCM450 Troubleshooting Guide Chapter 7 Downloading Software Use the information in t his chap ter to download BCM450 software. Navigation • Do wnloading software from the BCM450 we bpage on page 75 • Do wnloading software from the Nortel web site on page 77 Downloading software fr om the BCM450 webpage The BCM450 web p age facilitates the do ...

  • Nortel Networks BM450 - page 76

    76 Chapter 7 Downloa ding Software NN40160-700 NN40160-700 To download software fr om the BCM450 webpage 1 Connect to the BCM450 web p age: — If the BCM450 is installed o n the network use a bro wser and type in the BCM450 IP address as the URL in the follo wing format: http://xxx.xxx. xxx.xxx — If the BCM450 is installed b ut not yet co nf igu ...

  • Nortel Networks BM450 - page 77

    Chapter 7 Downloading Software 77 BCM450 Troubleshooting Guide http://10.10.11.1/ 2 Enter the user name and password to be authenticated on th e BCM450 web page. 3 Select the link for the type of app lication that you w ant to download. 4 Select the link for the specif ic application or to ol that you want to do wnload and select the do wnload link ...

  • Nortel Networks BM450 - page 78

    78 Chapter 7 Downloa ding Software NN40160-700 NN40160-700 ...

  • Nortel Networks BM450 - page 79

    79 BCM450 Troubleshooting Guide Chapter 8 Troubleshooting Tools The BCM450 system provides several tools that you can use to diagnose problems. Navigation • Service Management on page 79 • Status and Metrics on page 79 • Utilities on page 80 • Command Line Interface on page 80 Service Management You can use the Element Manager to view a lis ...

  • Nortel Networks BM450 - page 80

    80 Chapter 8 Troubleshoo ting Tools NN40160-700 NN40160-700 • Hunt Group Metrics—Access the Hunt Group met rics to evaluate total call processing by h unt group member. • PSTN Fallback Metrics—View how many fallback attempts and fallback failures occur within a specific period using the PSTN Fallback Metrics panel. • Proacti v e V oice Qu ...

  • Nortel Networks BM450 - page 81

    Chapter 8 Troubleshootin g Tools 81 BCM450 Troubleshooting Guide For either method, your user accou nt m ust be assigned the System-CLI privilege before you can access the CLI. Accessing the CLI through a serial connection 1 Connect a seri al cable with a 9-p in female co nnec tor from the serial port on a PC to t he serial port on the BCM450. 2 En ...

  • Nortel Networks BM450 - page 82

    82 Chapter 8 Troubleshoo ting Tools NN40160-700 NN40160-700 • 2—Shutdown . The system shuts do wn. Y ou need physical access to the BCM450 hardware to restart the system. • 3—Safe OS. The system reboots to the Safe OS an d waits 1 minute fo r you to login. When you login within 1 minut e, the Maintenance CLI displays. If yo u do not login w ...

  • Nortel Networks BM450 - page 83

    83 BCM450 Troubleshooting Guide Chapter 9 Understanding system messages The BCM450 system gen erates alarms, logs, traps, and oth er system messages that you can use to troubleshoot prob lems. Alarms, logs, and traps For information about system messages, see the following chapters in the BCM450 Fault and Performance Management Guide (NN40160 -701) ...

  • Nortel Networks BM450 - page 84

    84 Chapter 9 Understand ing system messages NN40160-700 NN40160-700 Detailed No setting A detailed e xplanati on of the Cause code is provided. Cause Code check bo x This check bo x appears when you select Simple in the Release Reason T ext drop-down menu. When you select the check bo x, only the cause code accompanies a dropped call notification. ...

  • Nortel Networks BM450 - page 85

    85 BCM450 Troubleshooting Guide Chapter 10 Useful Troubleshooting Links Use the information in t his chapter to find additional reference info rmation when you are troubleshooting a problem with the BCM450 system. As part of your initial troubleshooting, Nortel recommends that you check these resour ces for information abou t known issues and for s ...

  • Nortel Networks BM450 - page 86

    86 Chapter 10 Useful Tro ubleshooting Links NN40160-700 NN40160-700 To use the Knowledge and Solution Engine 1 Go to the Nortel W eb site: www .nortel.com 2 Log in using user name and password. 3 Select SUPPOR T & TRAINING . 4 Select ONLINE SELF-SER VICE , and then select Knowledge Base . The Online Self-Service page appears and sh ows the Kno ...

  • Nortel Networks BM450 - page 87

    87 BCM450 Troubleshooting Guide Chapter 11 Frequently Asked Questions The chapter provid e s an swer s to frequently asked questions. Navigation • Backup, restore, and reset operatio ns on page 87 • Password protection on page 89 • Fault management on page 90 • System and s tatus information on page 91 • Connectivity problems on page 95 ? ...

  • Nortel Networks BM450 - page 88

    88 Chapter 11 Frequen tly Asked Questions NN40160-700 NN40160-700 6 Click the Ye s button to proceed. A progress windo w opens. When the backup is complete, the Backup Complete message appears. 7 Click the OK button. How do I restore the BCM450 fr om a pre vious backup? Use the following procedure to restore th e BCM450 database. To restore data fr ...

  • Nortel Networks BM450 - page 89

    Chapter 11 Frequently Asked Quest ions 89 BCM450 Troubleshooting Guide Completing a warm or cold reset 1 Select Administration > Utilities > Reset , and click one of the follo wing b uttons: a Reboot BCM450 System will restart the operatin gsystem of the BCM450 b W arm Reset T elephony Services will restart telephony serv ices. Customer data ...

  • Nortel Networks BM450 - page 90

    90 Chapter 11 Frequen tly Asked Questions NN40160-700 NN40160-700 F ault management This section answers the follo wing frequently asked question: • Ho w do I view Alarms? Can I ackno wledge and clear them? on page 90 How do I vie w Alarms? Can I ac know ledge and c lear them? When you view an alarm on th e alarms pane l, you ca n change the orde ...

  • Nortel Networks BM450 - page 91

    Chapter 11 Frequently Asked Quest ions 91 BCM450 Troubleshooting Guide 4 T o change the order of columns in the Alarm table, select a column and drag it left or right to the desired location, and release it. 5 T o view a column b y ascending or descen ding order , click the column heading. To acknowledge an alarm 1 Click the Administration tab . 2 ...

  • Nortel Networks BM450 - page 92

    92 Chapter 11 Frequen tly Asked Questions NN40160-700 NN40160-700 5 Click the Tr a n s f e r b utton. The T ransfer T o windo w opens. 6 Select the log file cate gories that you want to in clude in the log f ile transfer . All the log f iles associated with the selected categories will be transferred. 7 Click the OK button. A transfer windo w opens ...

  • Nortel Networks BM450 - page 93

    Chapter 11 Frequently Asked Quest ions 93 BCM450 Troubleshooting Guide How do I ca pture the current BCM450 conf iguration? You can create a programming file that contains the current settings of all or part of your Element Manager data. These files can be saved in eith er HTML or Excel spr eadsheet format. You can access the programming record in ...

  • Nortel Networks BM450 - page 94

    94 Chapter 11 Frequen tly Asked Questions NN40160-700 NN40160-700 6 Click on Sa ve . How do I fi nd the BC M450 system health? You can use the BCM Monitor to view information about system health. The Usage Indicators tab on the BCM Monitor di splays real time information about the BCM450 system, including: • BCM450 system data, including CPU and ...

  • Nortel Networks BM450 - page 95

    Chapter 11 Frequently Asked Quest ions 95 BCM450 Troubleshooting Guide Verify the current software revision 1 Select Conf iguration > Sytem > Identif ication . How do find the BCM450 System ID and Serial Numb er? Use the following procedure to view the system ID and serial number. Viewing the system ID and serial number 1 Select Administratio ...

  • Nortel Networks BM450 - page 96

    96 Chapter 11 Frequen tly Asked Questions NN40160-700 NN40160-700 What is an Ethernet loop, an d how do I a v oid creating one? The BCM450 d oes not support the Bridging Protoco l Data Unit (BPDU), and therefore, yo u must be careful not to create Ethernet lops in th e network while connect ed ot these two ports. Figure 17 shows and Ethernet loop a ...

  • Nortel Networks BM450 - page 97

    Chapter 11 Frequently Asked Quest ions 97 BCM450 Troubleshooting Guide • Subnet mask: 255.255.255.0 The default addresses of the customer LAN port are: • IP address: 192.168 .2. 2 • Subnet mask: 255.255.254.0 ...

  • Nortel Networks BM450 - page 98

    98 Chapter 11 Frequen tly Asked Questions NN40160-700 NN40160-700 ...

  • Nortel Networks BM450 - page 99

    99 BCM450 Troubleshooting Guide Chapter 12 Contacting Technical Support If you have been unab le to resolve an issue using the information and steps provided in this guide, use the information in this chapte r to contact Nortel Technical Supp ort. This chapter identifies all of the critical information that you must gath er before contacting No rte ...

  • Nortel Networks BM450 - page 100

    100 Chapter 12 Contacting Technical Support NN40160-700 NN40160-700 — Who made these changes? W ere the changes ma de by a partner or customer? Provide the names of the individu als who made the ch an ges. • Actions taken: — Have you checked that the product’ s software or firmware is a Current or Sustained Release? — Have you checked whe ...

  • Nortel Networks BM450 - page 101

    Chapter 12 Conta cting Technica l Support 101 BCM450 Troubleshooting Guide Getting help fr om a specialist b y using an Express Routing Code To access some Nortel Technica l Solutions Center s, you can use an Express Routing C ode (ERC) to quickly route your call to a specialist in your Nortel product or service. To locate the ERC for your product ...

  • Nortel Networks BM450 - page 102

    102 Chapter 12 Contacting Technical Support NN40160-700 NN40160-700 ...

メーカー Nortel Networks カテゴリー Telephone

Nortel Networks BM450のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BM450の取扱説明書
- Nortel Networksの製品カード
- パンフレット
- またはNortel Networks BM450の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Nortel Networks BM450の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Nortel Networks BM450の取り付け説明書、サービスマニュアル、簡易説明書、またはNortel Networks BM450のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Nortel Networks BM450の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Nortel Networks BM450デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNortel Networks BM450を使用するのを助ける技術的文書のことです。説明書は通常、全てのNortel Networks BM450ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Nortel Networksの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Nortel Networks BM450の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNortel Networks BM450の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Nortel Networks BM450に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Nortel Networks BM450デバイスの基本機能を使うにあたってのヒント。 Nortel Networks BM450のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Nortel Networks BM450に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNortel Networks BM450のメーカー/サービスへの連絡先に関する情報。

Nortel Networks BM450についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNortel Networks BM450の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNortel Networks BM450で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)