  • Zephyr AK2000 - page 1

    2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE -/$%, AK2000,AK6000,AK9800   )MPORTANT3AFETY.OTICE 5SE#AREAND)NSTALLATION'UIDE : $51,1* 725('8&(7+(5,6.2)),5(25(/(&75,&6+2&.'2127 86(7+ ...

  • Zephyr AK2000 - page 2

    )MPORTANT3AFETY.OTICE 2EADANDSAVETHESEINSTRUCTIONS G 8VHDQH[WLQJXLVKHU21/ <LI < RXNQRZRXKDYHD&ODVV$%&H[WLQJXLVKHU DQGRXDOUHDGNQRZKRZ WRRSHUDWHLW  7KHILUHLVVPDOODQGFR ...

  • Zephyr AK2000 - page 3

    PRODUCT OVERVIEW WHIRLWIND SERIES HURRICANE SERIES CYCLONE SERIES 1 Model number: AK2000, 2036 QuattroVent Air Curtain Dual “Thrust-Fore" Self Clean Blowers Digital Touch Pad Controls Clock, Timer, 3 stage Delay Shutoff. Model number: AK9 8 00 Dual Self Clean Blowers Independent Rocker Controls w/ High, Low speed Slim Line Design Overview 1. ...

  • Zephyr AK2000 - page 4

    CONTROLS HURRICANE SERIES 2 Controls Overview 1. Set Time 2. Digital Display 3. Set Hours 4. Set Minutes 5. Set Timed Delay Shut Off 6. Light On-Off 7. Left Blower: On-High-Low-Off 8. Right Blower: On-High-Low-Off 9. Operations: On-Off 10. Right Blower Low Speed Indicator 11. Right Blower High Speed Indicator 12. Left Blower Low Speed Indicator 13. ...

  • Zephyr AK2000 - page 5

    Blower Controls You can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once. During this time, you can select blowers and speed as indicated by pressing the "Fan-L" and "Fan-R" button. Note: The third press on the "Fan-L" and "Fan-R" button will turn blower ...

  • Zephyr AK2000 - page 6

    CONTROLS 4 Setting Timer (Alarm) Press " hr " and " min " button to set desired timer countdown. Once timer is set, countdown will start in 7 seconds as delay indicator light flashes. When countdown reaches 0, 10 short beeps will sound. To cancel timer after setting, press "On/Of f" button to terminate all operations a ...

  • Zephyr AK2000 - page 7

    MAINTENANCE 5 Self Clean Feature All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for its self clean function. Grease and residue from cooking are often a ...

  • Zephyr AK2000 - page 8

    Hurricane Series: Remove light shield by turning counter- clockwise. Clean in dishwasher under normal wash cycle. Whirlwind Series: Remove light shield by unscrewing Philips screw. Clean in dishwasher under normal wash cycle. Cleaning Tip: Fill residue containers ¼ full with water before cleaning or during regular use. This will help to prevent gr ...

  • Zephyr AK2000 - page 9

    MAINTENANCE 7 QuattroVent Channels The QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No further cleaning is required after the self clean is completed. Clean residue around the channels surface with ‘409’ and a cotton cloth regularly. Replacing Lights All light bulbs included are 40W ...

  • Zephyr AK2000 - page 10

    INST ALLA TION 8 REQUIREMENTS ACCESSORIES WARNING Installation of this product is intended for qualified installers, service technicians, or persons with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could result form installing the unit due to lack of appropriate electrical knowledge and technical backgrou ...

  • Zephyr AK2000 - page 11

    INST ALLA TION 9 MIN. 18” MAX 30” net width DUCT OPENING CLEARANCES Front Rear Front Rear Wall Minimum clearance above range should be no less than 18“ from the range surface to the range hood’s base. Maximum height are recommended not to exceed 30” for maximum efficiency. Net width on all models are call out width less 1/4”. Note: Refe ...

  • Zephyr AK2000 - page 12

    INST ALLA TION 10 STEP 1 STEP 3 STEP 5 STEP 2 STEP 4 STEP 6 (also refer notes on pg. 16) 1. Remove all contents from box 2. Unscrew and remove bottom grease splash shield 1. Locate electrical connection box knock out from left rear of hood and pry open with screwdriver 1. Cut out cabinet base opening if necessary. Refer cut out dimensions previous ...

  • Zephyr AK2000 - page 13

    INST ALLA TION 11 STEP 7 STEP 9 (also refer notes on pg. 16) STEP 11 STEP 8 STEP 10 STEP 12 (also refer notes pg. 16) 1. Lift hood to bottom of cabinet 1. Support hood to place, fasten both rear with screws and washers provided. 1. Fasten front of hood. Level all sides and adjust accordingly.** 1. Drill out cabinet base through electrical box with ...

  • Zephyr AK2000 - page 14

    INST ALLA TION 12 STEP 13 STEP 15 STEP 17 STEP 14 STEP 16 STEP 18 1. On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening. 1. Turn on electrical supply or plug into receptacles. 1. Reinstall electrical box cover. 1. Next, fasten the 3 front screws and begin tightening all screws from rear to front. 1. Connect duct t ...

  • Zephyr AK2000 - page 15

    INST ALLA TION 13 CONVERTIBLE OPTIONS 3-1/4 x 10“ Vertical Discharge 1. Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in its original place. 3. Mount the 3-1/4 x 10“ starting collar on top of transition piece with remaining screws. 2. Place rectangular transition adaptor as shown over gasket and by first inst ...

  • Zephyr AK2000 - page 16

    INST ALLA TION 14 3-1/4 x 10“ Rear Discharge 4. At rear of range hood, remove all screws on pre- mounted rear rectangular cap and remove cap with gasket. 6. Remove 2 arch blocks through top opening. Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket. 7. Mount Starting Collar (prov ...

  • Zephyr AK2000 - page 17

    INST ALLA TION 15 3-1/4 x 10“ Rear Discharge Option 2: (for flush cabinet base) Mount rectangular transition piece at opening with gasket as shown. Mount rectangular cap (previously removed) on top of transition adaptor. ...

  • Zephyr AK2000 - page 18

    INST ALLA TION 16 INSTALLA TION NOTES Step 6: A damper (not included) should be installed to prevent back-draft where needed. A damper might also be required local codes in order to qualify for building inspections. You can purchase dampers from most hardware stores, or call our service line to order. When a damper is not installed, a starting coll ...

  • Zephyr AK2000 - page 19

    TROUBLE SHOOTING 17 1. Upon completion of installation, nothing works. 2. Light is on but blowers are not turning at all or seems to be scraping on something. 3. When blowers are on, something seems to be loose and spinning around inside. 4. Vibration when blowers are on 5. Blowers noise 6. Light is not working 7. No grease is collected in the resi ...

  • Zephyr AK2000 - page 20

    TROUBLE SHOOTING 18 11. Cooking fumes and smoke dissipates before it reaches the blower. Use a damper type sidewall cap. Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed and taped. Check if unit is installed at the recommended height (page 9). The range hood should also be able to cover the ent ...

  • Zephyr AK2000 - page 21

    www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of c harge, service lab or to repair any failed parts or components due to manufacturing defects. T en Y ears Parts W arranty: F or ten years from date of original purchase, we will provide free of c harge, nonconsuma ...

メーカー Zephyr カテゴリー Fan

Zephyr AK2000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AK2000の取扱説明書
- Zephyrの製品カード
- パンフレット
- またはZephyr AK2000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Zephyr AK2000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Zephyr AK2000の取り付け説明書、サービスマニュアル、簡易説明書、またはZephyr AK2000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Zephyr AK2000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Zephyr AK2000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがZephyr AK2000を使用するのを助ける技術的文書のことです。説明書は通常、全てのZephyr AK2000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Zephyrの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Zephyr AK2000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははZephyr AK2000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Zephyr AK2000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Zephyr AK2000デバイスの基本機能を使うにあたってのヒント。 Zephyr AK2000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Zephyr AK2000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるZephyr AK2000のメーカー/サービスへの連絡先に関する情報。

Zephyr AK2000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもZephyr AK2000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがZephyr AK2000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)