Antunes, AJ VS-350の取扱説明書

24ページ 1.5 mb
ダウンロード

ページに移動 of 24

Summary
  • Antunes, AJ VS-350 - page 1

    P/N 1010745 Rev . H 03/07 V ARIETY STEAMER Models VS-350 Owner ’ s Man ual M A N U F A C T U R I N G N U M B E R S : 9100700 9100710 9100712 9100714 9100720 A S D L I S T E CM O I N N I T A T C T I S L US E D ...

  • Antunes, AJ VS-350 - page 2

    V ARIETY STEAMER 2 P/N 1010745 Rev . G 03/06 General The V ariety Steamer produces steam using plain tap water for quick heating and reconstituting of food items. Simple push-button action delivers a fully adjustable impulse of steam. Because the amount of steam is consistent, it removes the guesswork and produces a uniform finished product from on ...

  • Antunes, AJ VS-350 - page 3

    3 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 Service/T echnical Assistance If you experience any problems with the installation or operation of your unit, contact your local Roundup Authorized Service Agency . They can be found in the service agency directory packaged with the equipment. Fill in the information below and have it handy when calling ...

  • Antunes, AJ VS-350 - page 4

    V ARIETY STEAMER 4 P/N 1010745 Rev . G 03/06 Throughout this manual, you will find the following safety words and symbols that signify important safety issues with regards to operating or maintaining your V ariety Steamer . W ARNING GENERAL W ARNING. Indicates informa- tion important to the proper operation of the equipment. Failure to observe may ...

  • Antunes, AJ VS-350 - page 5

    5 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 • W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THESE INSTRUCTIONS COULD RESUL T IN SERIOUS INJUR Y OR DEA TH. - E lectrical ground is required on this appli- ance. - Do not modify the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electricia ...

  • Antunes, AJ VS-350 - page 6

    V ARIETY STEAMER 6 P/N 1010745 Rev . G 03/06 SPECIFICA TIONS Electrical Ratings Shipping Weight 63 lbs. (28 kg) Electrical Cord & Plug Configurations CAUTION All electrical connections must be in accordance with local electrical codes and any other appli- cable codes. W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THE INSTRUCTIONS IN THIS ...

  • Antunes, AJ VS-350 - page 7

    7 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 Unpacking 1. Remove unit and all packing materials from ship- ping carton. 2. The unit should contain the following: • Owner ’s Manual • Authorized Service Agency Directory • Petro Gel T ube • Inlet Hose and Strainer Assembly • Black Drain T ubing NOTE: If any parts are missing or damaged, co ...

  • Antunes, AJ VS-350 - page 8

    V ARIETY STEAMER 8 P/N 1010745 Rev . G 03/06 CAUTION All electrical connections must be in accordance with local electrical codes and any other appli- cable codes. W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESUL T IN SERIOUS INJUR Y OR DEA TH. • Electrical ground is required on this appliance. • ...

  • Antunes, AJ VS-350 - page 9

    9 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 STEAMING GUIDE The V ariety Steamer makes it possible to expand a menu with just one piece of equipment. The V ariety Steamer produces a super-heated dry steam. This steam penetrates the product until the product’ s temperature matches the steam temperature. The guide below is an approximation of the n ...

  • Antunes, AJ VS-350 - page 10

    V ARIETY STEAMER 10 P/N 1010745 Rev . G 03/06 OPERA TION Operator Controls ROCKER SWITCH (POWER ON/OFF) When the Rocker Switch (Power On/OFF) is in the ON position, the Control Board is activated. If the genera- tor temperature is below the factory preset setpoint, power is applied to the generator until the setpoint temperature is reached. The gen ...

  • Antunes, AJ VS-350 - page 11

    1 1 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 UP & DOWN ARROW BUTTONS The actual generator temperature can be viewed by depressing the UP arrow button (Figure 3) at any time. The arrow buttons are used with the other buttons to program the unit (see the Programming section of this manual for more information). LOCK LEVER When in the full forwa ...

  • Antunes, AJ VS-350 - page 12

    V ARIETY STEAMER 12 P/N 1010745 Rev . G 03/06 General Programming CYC (T otal Cycle Time) refers to the total amount of cooking time set for the product (Figure 4). RA TE (Shot Interval Time) is the time set between each shot of steam during a complete cycle (Figure 5). PROGRAMMING UP DOWN PROG RAM ST ART/ST OP 4 0 0 F T o verify or change the gene ...

  • Antunes, AJ VS-350 - page 13

    13 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 UP DOWN PR OGRA M SING LE SHO T 1 2 3 4 S H O T Figure 6. SHOT Mode on Menu 1 UP DOWN PR OGRA M SING LE SHO T 1 2 3 4 0 0 : 1 0 Figure 7. Programming Mode SINGLE SHOT Button Used for Saving All Changed Settings. CYC (T otal Cycle Time) 1. T urn the Rocker Switch (power On/Off) to ON (Figure 3). Allow 30 ...

  • Antunes, AJ VS-350 - page 14

    V ARIETY STEAMER 14 P/N 1010745 Rev . G 03/06 the steam generator hole. T ake a suitable 1/16” punching tool (such as a paperclip) and fully insert it through all 18 orifices in the black manifold as well as through the 10 orifices in the spray tube. This assures the orifices are not obstructed with debris. W ash all items in hot, soapy water . R ...

  • Antunes, AJ VS-350 - page 15

    15 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 4. Wearing protective eyewear and gloves, pour delimer solution (not supplied) onto the generator surface (Figure 8). Be sure to follow the delimer manufacturer ’s directions for proper mixture and use. Figure 8. V ariety Steamer Components & Accessories O- r in g (m u st b e lu b ri ca t ed da i ...

  • Antunes, AJ VS-350 - page 16

    V ARIETY STEAMER 16 P/N 1010745 Rev . G 03/06 Diagnostics The four-channel controller is also equipped with diag- nostic features. Listed under each drawing is a brief description of the particular feature. Also contained in the control housing mounted on the control board are diagnostic LED’s. They are in three colors and repre - sent the follow ...

  • Antunes, AJ VS-350 - page 17

    17 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 UP DOWN PR OGRA M SING LE S HOT 1 2 3 4 SHOT PWR (Power) will be displayed when the supply volt- age is lower than 160 V olts AC or above 265 V olts AC. PWR UP DOWN PR OGRA M SING LE S HOT 1 2 3 4 SHOT OPEN will be displayed when the thermocouple is “open” or not installed correctly . The unit will ...

  • Antunes, AJ VS-350 - page 18

    V ARIETY STEAMER 18 P/N 1010745 Rev . G 03/06 T echnical Theory of Operation When the Rocker Switch (power On/Off) is ON, line voltage flows to the primary side of the step down transformer . The transformer ’s secondary side supplies 12 and 24 V AC to the Control Board. Once powered, and provided that the generator ’s tem- perature is below th ...

  • Antunes, AJ VS-350 - page 19

    19 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 TROUBLESHOOTING W ARNING T o avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip - ment should be performed by qualified service personnel. The unit should be unplugged when servicing, except when electrical tests are required. Problem Possible Cause ...

  • Antunes, AJ VS-350 - page 20

    V ARIETY STEAMER 20 P/N 1010745 Rev . G 03/06 TROUBLESHOOTING (continued) Problem Prossible Cause Corrective Action Unit heats but there is little or no steam produced and/or The product requires more steaming than usual (continued). Improper water pressure to unit. V erify that a water pressure regulator is installed and set to 20 - 25 psi. Insuff ...

  • Antunes, AJ VS-350 - page 21

    21 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 WIRING DIAGRAM # BLK RED BLK BRN ORG GRN YEL T10 T9 T8 T7 T6 T5 T1 T2 T3 T4 4- 3+ 1 2 RED YEL BLUE ORG BLK # BRN # # # T11 BLK BLK WHT BLK WHT 230V SOLENOID 4 2 WHT 6 8 5 1 10 TRANSFORMER BLK WHT CORD BLOCK POWER TERMINAL GRN GND SWITCH POWER 1 2 4 5 # # BOARD SWITCH BOARD S.S. RELAY THERMOCOUPLE CONTRO ...

  • Antunes, AJ VS-350 - page 22

    V ARIETY STEAMER 22 P/N 1010745 Rev . G 03/06 41 39 40 42 21 33 22 47 29 48 27 24 25 26 28 49 1 1 10 51 52 50 9 55 53 54 7 15 14 13 12 36 23 1 8 37 38 3 5 8 19 45 44 46 17 18 16 58 59 2 4 6 Available with L6-30P or CEE 7/7 20 62 63 64 64 34 61 32 18 17 65 67 66 41 43 43 68 35 REPLACEMENT P ARTS ...

  • Antunes, AJ VS-350 - page 23

    23 V ARIETY STEAMER P/N 1010745 Rev . G 03/06 REPLACEMENT P ARTS (continued) Item Part Description Qty . No. Item Part Description Qty . No. 1 001 1539 T op Housing Assy . (Jumbo) 1 2 7000404 Generator Manifold (incl. #66 & 67) 1 3 0200187 O-Ring 1 4 0020947 Drip Tray Assy . 1 5 7000293 Generator , (208V) 5000w 1 7000295 Generator , (230V) 5000 ...

  • Antunes, AJ VS-350 - page 24

    LIMITED W ARRANTY Equipment manufactured by Roundup Food Equipment Division of A.J. Antunes & Co. has been con- structed of the finest materials available and manufactured to high quality standards. These units are warranted to be free from mechanical and electrical defects for a period of one year from date of pur- chase or 18 months from ship ...

メーカー Antunes, AJ カテゴリー Electric Steamer

Antunes, AJ VS-350のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- VS-350の取扱説明書
- Antunes, AJの製品カード
- パンフレット
- またはAntunes, AJ VS-350の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Antunes, AJ VS-350の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Antunes, AJ VS-350の取り付け説明書、サービスマニュアル、簡易説明書、またはAntunes, AJ VS-350のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Antunes, AJ VS-350の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Antunes, AJ VS-350デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAntunes, AJ VS-350を使用するのを助ける技術的文書のことです。説明書は通常、全てのAntunes, AJ VS-350ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Antunes, AJの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Antunes, AJ VS-350の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAntunes, AJ VS-350の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Antunes, AJ VS-350に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Antunes, AJ VS-350デバイスの基本機能を使うにあたってのヒント。 Antunes, AJ VS-350のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Antunes, AJ VS-350に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAntunes, AJ VS-350のメーカー/サービスへの連絡先に関する情報。

Antunes, AJ VS-350についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAntunes, AJ VS-350の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAntunes, AJ VS-350で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)