Breckwell P2000Iの取扱説明書

31ページ 0.72 mb
ダウンロード

ページに移動 of 31

Summary
  • Breckwell P2000I - page 1

    PROFESSIONAL INSTALL ATION IS HIGHLY RECO MMENDED Manufactured by National Steelcrafters of Oregon, Inc. DBA Breckwell Hea r th Products Eugene, Oregon Grand Prairie, Texas • Warning: If your appliance is not properly installed a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials a ...

  • Breckwell P2000I - page 2

    Thank you for purchasing the Breck well Pellet Burning Stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of ...

  • Breckwell P2000I - page 3

    Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. Never try to repair or replace any part of the stove unless instructions are given in this manual. All othe r work should be done by a trained technician. Never use gasoline, gasoline - type lantern fuel, kerosene, charcoal lighter fluid, or ...

  • Breckwell P2000I - page 4

    INTRODUCTION ----------------------------------------------- ------------------------------------ ---------- 2 SAFETY PRECAUTIONS ------------------------------------------------------------------------ ---------- 3 SPECIFICATIONS --------------------------------------------------------------------------------- ---------- 5 INSTALLATION ----------- ...

  • Breckwell P2000I - page 5

    FREESTANDING Width: 29 1/8” Height: 30 1/8” Depth: 22 5/8” W eight: 300 lbs. Flue size: 3” or 4” Hopper Capacity: Up to 70 lbs. (This can vary widely depending on pellet size, length, and diameter) EPA status: exempt Burn rate: 1 lb. to 5.5 lbs. per hour BTU range: 8,200 to 50,000 Approved installations: mobile home, alcove, conventional ...

  • Breckwell P2000I - page 6

    COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 2” inside diameter metallic pipe, either flexible or rigid, m ay be attached to the inlet at the stove’s rear (refer to figures 5 & 6). A rodent guard (minimum ¼” wire mesh)/wind hood must be used at the terminus (re ...

  • Breckwell P2000I - page 7

    Equivalent Vent Length (EVL) The longer the run of pipe in your installation (both with insert and freestanding ), the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of Equivalent Vent Length. • Horizontal runs shall not exceed 10 feet of EVL. • Recommende ...

  • Breckwell P2000I - page 8

    A. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9) NOTE: Follow L - Vent chimney manufacturer’s instructions. OPTION: To achieve a c enter vertical installation a 45º elbow and a clean - out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove. OPTION: Install L - Vent elbow in place of clean - out te ...

  • Breckwell P2000I - page 9

    C. VERTICALLY INTO EXISTING MASONRY FIREPLACE NOTE: Follow L - Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qualified chimney sweep or ins taller to determine its structural condition. 2. You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used, you wi ...

  • Breckwell P2000I - page 10

    INSERT INSTALLATIONS Insert installations must be vented with 3” or 4” pipe. Pipe may be single wall stainless steel flexible pipe. Vent may terminate within chimney beyond a blanking plate or extend to the chimney top. See “ COMBUST ION AIR SUPPLY ” for outside air access information. The fireplace and chimney should be cleaned thoroughly ...

  • Breckwell P2000I - page 11

    B. WHEN VENT PIPE EXTENDS TO CHIMNEY TOP (Refer to Figure 15) 1. You will need a pipe length equal to the chimney height (from hearth) plus 6 inches. If outside combustion air is to be used, you will need a pipe length (see “ COMBUSTION AIR SUPPLY ” ) equal to the chimney height plus 12 inches. 2. Attach cerabla nket wrap to that end of vent pi ...

  • Breckwell P2000I - page 12

    D. AS A BUILT - IN FIREPLACE Figures 16 and 17 describe a P2000 installation vented into either a special chase built outside an outer wall or a false insi de wall. This is especially suited for new construction or remodeling. The equipment compartment (sides and rear of the stove in fireplace) must be enclosed per the applicable electrical standar ...

  • Breckwell P2000I - page 13

    E. INSTALLATION IN TO A FACTORY BUILT (METAL) FIREPLACE (refer to figure 18) When installing into a factory built fireplace, the firebox must accept the insert without modification other than removing bolted or screwed together pieces such as smoke shelf/deflectors, ash lips, screen or door tracks and damper assemblies. These items must be reinstal ...

  • Breckwell P2000I - page 14

    PANEL CONTROLS (See Figure 19) The blowers and automatic fuel supply are controlled from a panel on the left - hand side of t he P2000. The control panel functions are as follows. a. ON/OFF SWITCH • When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will stay on for at least 10 and up to 15 minutes, de ...

  • Breckwell P2000I - page 15

    PROPER FUEL THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory - approved pellets are those ¼” or 5/16” in diameter a nd not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building ...

  • Breckwell P2000I - page 16

    RE - STARTING A WARM STOVE If the stove has been shut off, and you want to re - start it while it is still warm, the “on/off” button must be held down for 2 seconds. IF STOV E RUNS OUT OF PELLETS The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes. After the stove components stop run ...

  • Breckwell P2000I - page 17

    OPTIONAL THERMOSTAT A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fixed wall mount or Breckwell’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat m ode. THERMOSTAT INSTALLATION • A MILLIVOLT THERMOSTAT IS REQUIRED. ? ...

  • Breckwell P2000I - page 18

    OPERATING SAFETY PRECAUTIONS PLEASE READ THIS! a. Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns. b. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in firebox, immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the dampe ...

  • Breckwell P2000I - page 19

    FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN P OOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly. ASH REMOVAL Ashes should be placed in a metal container with a tight - fitting lid. The close d container or ashes shou ...

  • Breckwell P2000I - page 20

    VACUUM USE If a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes. (We recommend LoveLess Ash Vac, 1 - 800 - 568 - 3949 Ext. #27) Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage. CLEANING a. Heat Exchange Tubes – Y ...

  • Breckwell P2000I - page 21

    CHIMNEY CLEANING a. Creosote Formation – When any wood is burned slowly, it pr oduces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow - burning fire. As a result, creosote residue accumulates on t he flue li ...

  • Breckwell P2000I - page 22

    MAINTENANCE 22 FIGURE 28 P2000I ...

  • Breckwell P2000I - page 23

    When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solv e simple problems yourself. Problems can be caused by to only five factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect. You can usually solve ...

  • Breckwell P2000I - page 24

    STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The hopper is out of pellets. Refill the hopper. 2. The air damper is too far open for a low feed setting. If burning on the low set ting, you may need to close the damper all the way (push the knob in so it touches the side of the st ...

  • Breckwell P2000I - page 25

    STOVE FEEDS PELLETS, BUT WI LL NOT IGNITE Possible Causes: Possible Remedies: 1. Air damper open too far for ignition. Push the air damper in closer to the side of the stove for startup. In some situations it may be necessary to have the damper completely closed for ignition to ta ke place. After there is a flame, the damper can then be adjusted fo ...

  • Breckwell P2000I - page 26

    STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes : Possible Remedies: 1. F use on control board blew Remove the control board. On the back there is one fuse. If it appears to be bad, replace it with a 5 Amp 250 Volt fuse. Plug the stove back in and try to run the unit. 2. High limit switch has t ripped or is def ...

  • Breckwell P2000I - page 27

    • GLASS “SOOT’S” UP AT A VERY FAST RATE • FLAME IS LAZY, DARK, AND HAS BLACK TIPS • AFTER STOVE HAS BEEN ON FOR A WHILE, T HE BURNPOT OVERFILLS Possible Causes: Possible Remedies: 1. Stove or vent pipe is dirty, which restricts airflow through the burnpot. Follow all cleaning procedure in the maintenance section of the owner’s manual. ...

  • Breckwell P2000I - page 28

    HIGH LIMIT SWITCH KEEPS TRIPPING Possible Causes: Possible Remedies: 1. The co nvection blower is overheating and tripping the internal temperature shutoff. C lean any dust off of the windings and fan blades. If cleaning the blower does not help, it may be bad. 2. The stove is being left on the highest setting for extended periods of time. The high ...

  • Breckwell P2000I - page 29

    ELECTRICAL DIAGRAM FIGURE 29 29 ...

  • Breckwell P2000I - page 30

    Contact an Authorized Breckwell Pellet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non - approved parts can result in poor performance and safety hazards. ITEM PART # Air Switch C - E - 201 Air Switch Hose C -M- 340 - T Auger Motor C - E - 017 Brec kwell Maintenance Tool A - TOOL - 96 Brick Panel Set, Ceramic ? ...

  • Breckwell P2000I - page 31

    LIFETIME LIMITED WARRANTY Breckwell Hearth Products warrants to the original consumer purchaser that the Breckwell stove in its original installation is free from defects in material and workmanship from the original date of purchase as follows: Steel fabricated components, excluding burnpot inserts, are covered f or five years. Glass and burnpot i ...

メーカー Breckwell カテゴリー Stove

Breckwell P2000Iのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- P2000Iの取扱説明書
- Breckwellの製品カード
- パンフレット
- またはBreckwell P2000Iの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Breckwell P2000Iの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Breckwell P2000Iの取り付け説明書、サービスマニュアル、簡易説明書、またはBreckwell P2000Iのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Breckwell P2000Iの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Breckwell P2000Iデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBreckwell P2000Iを使用するのを助ける技術的文書のことです。説明書は通常、全てのBreckwell P2000Iユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Breckwellの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Breckwell P2000Iの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBreckwell P2000Iの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Breckwell P2000Iに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Breckwell P2000Iデバイスの基本機能を使うにあたってのヒント。 Breckwell P2000Iのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Breckwell P2000Iに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBreckwell P2000Iのメーカー/サービスへの連絡先に関する情報。

Breckwell P2000Iについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBreckwell P2000Iの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBreckwell P2000Iで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)