    © 2006 Ingersoll-Rand Company Limited Hardware Products 121 West Railroad Avenue Princeton, I L 6 1356 -0100 1-800-52 6 - 2400 F A X: 800- 248- 1460 w w w . lcn.ingersollrand .com LC N LC N 7940-8770 Presence Sensor ® ® Installation Instructions ...

  • Ingersoll-Rand LCN 7940-8770 - page 2

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 1 of 11 DESCRIPTION TECHNICAL SPECIFICATIONS COMPONENT ID INSTALLATION TIPS  The sensor must be firmly fastened to prevent vibration. The LCN Presence Sensor (PN: 750182-00) is a self-moni tored re ady overhead-mounted diffused active infrared sensing device that provides detection for the triggering of aut ...

  • Ingersoll-Rand LCN 7940-8770 - page 3

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 2 of 11 SA FETY PRECAUTIONS ME CH ANI CAL INSTALLATION - PREPARATION ME CH ANI CAL INSTALLATION – PLACEMENT OF THE SENSOR Wa l l Sw it ch Wal l Sw it ch Presen ce Sens or 20” min 20” m in Presence Sensor • Shut off all power going to the header before atte mpting any wiring procedures. • Maintain a c ...

  • Ingersoll-Rand LCN 7940-8770 - page 4

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 3 of 11 ELECTRICAL INSTALLATION AND CAB LING ME CH ANI CAL INSTALLATION 1. The extrusion has pre-drilled mounting holes at each end as shown below in pictures 5 & 6. 2. Hold the Presence Sensor up to the pre-determined location, and attach using the 2 self-drilling screws that are included with the package ...

  • Ingersoll-Rand LCN 7940-8770 - page 5

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 4 of 11 ME CH ANI CAL ADJ UST MENT S POWER-UP PROCEDURES Once all installation, wiring and cabling procedures hav e been completed, mecha nical adjustments can be made. Please note that further adjustments may be required afte r powering and walk testing the detection field. Aside from placement on the header, ...

  • Ingersoll-Rand LCN 7940-8770 - page 6

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 5 of 11 LCN’S UNIVERSAL REMOTE CONTROL DOUBLE EGREES: REDUCING CROSS TALK Perform the following set up using LCN’s remote control to r educe cross talk between duel egress a pplications. Refer to the figure on page 2 to ensure the two Presence Sensors are in stalled with at least 40” of separation when m ...

  • Ingersoll-Rand LCN 7940-8770 - page 7

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 6 of 11 PROGRAMMING GUIDE – GENERAL FUNCTIONS REMOTE P/N 7940-461 NOTE : AUTOMATI C SETUP : When performing an automatic setup (setup key pre ssed twice in a row), the sensor will begin to flash green during the door closed position, and w ill continue to do so until the do or is activated to the open positi ...

  • Ingersoll-Rand LCN 7940-8770 - page 8

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 7 of 11 PROGRAMMING GUIDE – PA TTERN ADJ UST MENT S NOTE : THRESHOLD : The Threshold is always O FF when the door is closed. NOTE : PATTERN WIDTH OR DEPTH : When pattern width or depth is changed, a setup of the new pattern size will automatically be triggered once a value key has been pressed. Pattern Width ...

  • Ingersoll-Rand LCN 7940-8770 - page 9

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 8 of 11 MA NUAL (NON-REMOTE) SET-UP Without the LCN Remote Control, the Presence Sens or may be set up using the manual push buttons (see diagram below) located under the right end cap. Only the s ensitivity, relay mode, auto-learn time, pattern width, and pattern depth may be adjusted with the manual push but ...

  • Ingersoll-Rand LCN 7940-8770 - page 10

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 9 of 11 PRESENCE SENSOR WIDTH PA TTERN S PRESENCE SENSOR DEPTH PA TTERN S Row 1 (spots 1 through 6), remain on, even during the closed door position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

  • Ingersoll-Rand LCN 7940-8770 - page 11

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 10 of 11 TROUBLE- SHOOTING PRESENCE SENSOR DEPTH PA TTERN S - Cont. Row 1 (spots 1 through 6), are on during open doo r position and off during closed door position. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 1 ...

  • Ingersoll-Rand LCN 7940-8770 - page 12

    75.5255.02 XXXXXXXX 7940-8770 LCN Page 11 of 11 TROUBLE- SHOOTING – Cont. ACCESSORIES PROBLEM PROB A BLE C A U SE CORRECTIVE ACTION 1. Allow the door to open in the automatic mode. Unlock the Presence Sensor and launch a setup by pressing the Setup key, followed by the number 2. If the sensor does not begin flashing green, and instead goes back t ...

メーカー Ingersoll-Rand カテゴリー Home Security System

Ingersoll-Rand LCN 7940-8770のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LCN 7940-8770の取扱説明書
- Ingersoll-Randの製品カード
- パンフレット
- またはIngersoll-Rand LCN 7940-8770の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Ingersoll-Rand LCN 7940-8770の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Ingersoll-Rand LCN 7940-8770の取り付け説明書、サービスマニュアル、簡易説明書、またはIngersoll-Rand LCN 7940-8770のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Ingersoll-Rand LCN 7940-8770の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Ingersoll-Rand LCN 7940-8770デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがIngersoll-Rand LCN 7940-8770を使用するのを助ける技術的文書のことです。説明書は通常、全てのIngersoll-Rand LCN 7940-8770ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Ingersoll-Randの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Ingersoll-Rand LCN 7940-8770の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははIngersoll-Rand LCN 7940-8770の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Ingersoll-Rand LCN 7940-8770に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Ingersoll-Rand LCN 7940-8770デバイスの基本機能を使うにあたってのヒント。 Ingersoll-Rand LCN 7940-8770のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Ingersoll-Rand LCN 7940-8770に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるIngersoll-Rand LCN 7940-8770のメーカー/サービスへの連絡先に関する情報。

Ingersoll-Rand LCN 7940-8770についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもIngersoll-Rand LCN 7940-8770の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがIngersoll-Rand LCN 7940-8770で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)