Fluke 561の取扱説明書

22ページ 0.79 mb
ダウンロード

ページに移動 of 22

Summary
  • Fluke 561 - page 1

    ® 561 HV A CPr o Infrared Thermometer Users Manual PN 2562924 February 2006 © 2006 Fluke Corp oration, All ri ghts reserved. Pr inted in USA All product names ar e trademarks of their respective c ompanies. ...

  • Fluke 561 - page 2

    LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defect s in material and workmanship for two years from the date of purchase. This warranty do es not cover fuses, disposable batteries, or damage from accident, neglect , misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers ar ...

  • Fluke 561 - page 3

    i Table of Contents Title Page Introducti on ............................................................................................. 1 Contacting Fluke ...................................................................................... 1 Safety Information ................................................................................... ...

  • Fluke 561 - page 4

    561 HVACPro Users Manual ii Measuring Grille, Registe r, or Diffuser Discharge Tempe rature ......... 15 Verifying Thermostat/ Room Sensor Acc uracy .................................... 15 Checking for Blockage in Air-To-Air Evaporators or Condensers........ 15 Checking Superheat on Fixed Restrictor or Capillary Tube Equipped Evapor ators ......... ...

  • Fluke 561 - page 5

    1 561 HVAC PRO Infrared Thermometer Introduction The Fluke Model 561 HVACPro Infrared Thermometer (hereafter, “the Thermometer”) can determine the surface temperature by measuring the amount of infrared energy radiated by the ta rget’s surface or by contact using a thermocouple probe. The Thermomete r was designed specif ically for use in hea ...

  • Fluke 561 - page 6

    561 HVACPro Users Manual 2 Safety Information W Warning A Warning identifies conditi ons and actions that pose haz ards to the user. To avoid el ectrical shock or personal injury, foll ow these guidelines: • * Do not point laser direct ly at eye or indirectly off reflective surfaces. • Before using the Ther mometer inspect the case. Do not use ...

  • Fluke 561 - page 7

    Infrared Thermometer Features 3 A V O I D E X P O S U R E - L A S E R R A D IA T IO N IS E M IT T E D F R O M T H IS A P E R T U R E CA UTION L A S E R R A D IA T IO N - D O N O T S T A R E IN T O B E A M O U T P U T < 1 m W W A V E L E N G T H 6 3 0 - 6 7 0 n m C L A S S 2 ( II ) L A S E R P R O D U C T C O M P L IE S W IT H F D A 2 1 C F R 1 0 ...

  • Fluke 561 - page 8

    561 HVACPro Users Manual 4 AA Batteries (2) Display Function Buttons Laser T rigger Battery Cover efh007f.eps Figure 2. Infrared Th ermometer Display The primary temperature display reports the current or last IR temperature read until the 7-second hold time elapses. The secondary temperature display reports current th ermocouple temperature when a ...

  • Fluke 561 - page 9

    Infrared Thermometer Buttons and Connector 5 3 4 5 6 2 1 8 7 efh01f.eps A Laser “On” symbol B SCAN or HOLD C ° C/ ° F symbol (Celsius/Fahrenheit) D Primary temperature display E Secondary temperature display F Emissivity LO, MED, HI G Temperature values for the MIN, MAX, DIF, KTC. KTC indicates the thermo couple temperature. H Low Battery sym ...

  • Fluke 561 - page 10

    561 HVACPro Users Manual 6 How the Thermometer Works Infrared thermometers m easure the surface tempera ture of an opaque object. The Thermometer’s optics sense infrared energy, whic h is collected and focused onto a detector. The Thermometer’s electronics then translate the information in to a displayed temperature reading which appears on the ...

  • Fluke 561 - page 11

    Infrared Thermometer Operating the Thermometer 7 D:S=12:1 38 mm @ 300 mm 75 mm @ 900 mm 132 mm @ 1500 mm 1.5 " @ 12 " 3 " @ 36 " 5.3 " @ 60 " S D efh005f.eps Figure 5. Distance and Spot Size Field of View Make sure that the target is larger than the spot size . The smaller the target, the closer you should be to it. Se ...

  • Fluke 561 - page 12

    561 HVACPro Users Manual 8 Table 2. Surface Emissi vity Measured Surface Switch Setting Measured Surface Switch Setting Aluminum Iron, Cast Oxidized Low Oxidized High, Medium Alloy A3003 Unoxidized Low Oxidized Low Molten Low Roughened Low Iron, Wrought Brass Dull High Burnished Low Lead Oxidized Low Rough Low Copper Oxidized Low, Medium Oxidized M ...

  • Fluke 561 - page 13

    Infrared Thermometer Operating the Thermometer 9 Switch efh012f.eps Figure 7. Switching Bet ween ° C and ° F Using the Contact Temperature Probe XW  Warning To avoid electri cal shock or personal injury, do not connect the optional external probe to l ive electrical circuits. Connect the probe to the input on the t op of the The rmometer. The ...

  • Fluke 561 - page 14

    561 HVACPro Users Manual 10 Table 3 lists recommended Fluke temperatur e probes for use with the Thermometer: Table 3. Recommended Tem perature Probes Probe Usage 80PK-25 The piercing probe is the most versatile option. Good for checking air temperature in ducts, surface temperature under carpets/pads, liquids, thermometer wells, vent temperatures, ...

  • Fluke 561 - page 15

    Infrared Thermometer Typical Measurements 11 • The most likely conditions for condensation form ation are low dry bulb te mperat ure and high wet bulb temperature (low temperat ure, high relat ive humidity). • Use the Fluke 971 to measure the attic/crawlspace relative humidity and determine the dew point temperature. This is the temperature at ...

  • Fluke 561 - page 16

    561 HVACPro Users Manual 12 Testing Contactors (Starters) 1. Press D to select emissivity. Press A to select LO for bright c ontacts, or MED for darkened contacts. 2. Press C and the press A to select MAX. 3. Measure line and load side of one pole without releasing trigger. 4. A temperature difference between th e line and load sides of a pole indi ...

  • Fluke 561 - page 17

    Infrared Thermometer Typical Measurements 13 Testing Bearings W Warning To avoid injury when t esting bearings: • Do not wear loose clothi ng, jewelry, or anything around neck when working around moving parts such as motors, belts, blower, and f ans. • Make sure an electrical di sconnect is within reach a nd operating correctl y and freely. • ...

  • Fluke 561 - page 18

    561 HVACPro Users Manual 14 wall you should find parallel isotherm al rows indicating the location of heat t ubes below the surface. Perpendicular to the outside wall, you should fi nd rising and falling temp erat ures at equal distances. High temperatures indicate you are scanning a heat tube be neath the floor surface, low falling temperature s i ...

  • Fluke 561 - page 19

    Infrared Thermometer Typical Measurements 15 • If system pressure has been incr eased above design settings, this can result in sympto m of trap failure (stuck open). Check steam pressure. 1. Press D and then press A to select HI emissivity for bl ack iron pipe and painted traps. 2. Press C and then press A to select DIF. 3. Aim the Thermometer a ...

  • Fluke 561 - page 20

    561 HVACPro Users Manual 16 • All condenser return bend/hairpi ns should be at or slightly less than condenser saturation temperature. • If a group of return bends/hairpins do not confor m to expected temperatures, that indicates a blocked or restricted distri butor or dist ributor tube. Checking Superheat on Fixed Restrictor or Cap illary Tube ...

  • Fluke 561 - page 21

    Infrared Thermometer Maintenance 17 Maintenance Changing the Battery To install or change the two AA batteries, open the battery compartment and insert the batteries as shown in Figure 2. Cleaning the Lens Blow off loose particles using clean compressed air. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water. ...

  • Fluke 561 - page 22

    561 HVACPro Users Manual 18 Specifications Infrared Measurement Range ................................................................ -40 ° C to 550 ° C (-40 ° F to 1022 ° F) Spectral Range ......................................................................... 8 to 14 microns Accuracy ........................................................ ...

メーカー Fluke カテゴリー Thermometer

Fluke 561のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 561の取扱説明書
- Flukeの製品カード
- パンフレット
- またはFluke 561の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Fluke 561の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Fluke 561の取り付け説明書、サービスマニュアル、簡易説明書、またはFluke 561のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Fluke 561の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Fluke 561デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがFluke 561を使用するのを助ける技術的文書のことです。説明書は通常、全てのFluke 561ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Flukeの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Fluke 561の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははFluke 561の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Fluke 561に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Fluke 561デバイスの基本機能を使うにあたってのヒント。 Fluke 561のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Fluke 561に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるFluke 561のメーカー/サービスへの連絡先に関する情報。

Fluke 561についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもFluke 561の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがFluke 561で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)