Airflow Systems IAQ50の取扱説明書

40ページ 0.2 mb
ダウンロード

ページに移動 of 40

Summary
  • Airflow Systems IAQ50 - page 1

    Indoor Air Quality Meter Model IAQ50 OWNER’S MANUAL ...

  • Airflow Systems IAQ50 - page 2

    ii LI MI T A T I ON OF W AR R AN T Y AN D L I AB I L IT Y Seller warrants th e goods sold hereu nder, under norm al use and service as described in the operator's manual, shall be f ree from defects in wor kmanship and mater ial for twenty-four (24) m onths, or the length of time specified in t he operator's m anual, from the date of ship ...

  • Airflow Systems IAQ50 - page 3

    3 Table of Contents LIMITATION OF WARRANTY AND LIABILITY ................................................................... ii SECTION 1 General Descript ion ................................. 5 SECTION 2 Sa fety ........................................................... 6 SECTION 3 Setting-U p .................................................. 7 ...

  • Airflow Systems IAQ50 - page 4

    4 SECTION 5 Maintena nce ............................................ 2 6 Probe Tip ..................................................................... 26 Cases ............................................................................ 27 Storage ......................................................................... 27 SECTION 6 Service and ...

  • Airflow Systems IAQ50 - page 5

    5 SECTION 1 General Description The Model IAQ50 measures Carbon Dioxide (CO 2 ) level, t emperature an d relative humidity, and calculates dew point and wet bulb. It also calcul ates the percentage of outside (make up) air in a given indoor space, using CO 2 levels, or temperature. The instrument will deter- mine statistic s and recall individual d ...

  • Airflow Systems IAQ50 - page 6

    6 SECTION 2 Safety When using the IAQ50 to check for CO 2 , temperature or humi dity values, make certain that y ou can safely raise and hol d the instrument while m aking measure- ments. Be especially careful when wo rking on a ladder. Observe all necessary prec autions so that the unit does not become caught in moving machinery or touch any expos ...

  • Airflow Systems IAQ50 - page 7

    7 SECTION 3 Setting-Up Supplying Po wer to the Model IAQ50 The Model IAQ50 can be powered in one of two ways: four AA-size batteries or an optional AC ad apter. Installing the Batteries Insert four AA batteries as indicated by the diagram located on the inside of the battery compartment. The Model IAQ50 is designed to operate only with alkaline bat ...

  • Airflow Systems IAQ50 - page 8

    8 Start up Sequence for the Model IAQ50 When the instrument is turned on, all segments of the display wi ll light up and then the meter goes through a start-up sequence. Battery Percentage This shows the remainin g amount of battery power. Log Percentage This shows how much of t he datalog- ging memory is sti ll availa ble. Baud Rate The Model IAQ5 ...

  • Airflow Systems IAQ50 - page 9

    9 and time stamping of recorded data w ill not be correct. To set the time and date, press and hold either 5 or 6 key during the power-up sequence when the time is displayed. Release the keys when the Model IAQ50 beeps twice. You will have an opportu- nity to view and/or change the minutes (min), hours, year, month and date in sequence. Use the 5 o ...

  • Airflow Systems IAQ50 - page 10

    10 sequence , press and ho ld the ENTER key at any point of the start-up sequence, until the meter b eeps. Using the Sensing Probe The sensing probe relies on the diffusion of air. For best results, try to keep the sensing probe surrounded by moving air. Do not breathe on the probe, since humans exhale levels well exceeding 10, 000 ppm CO 2 and it ...

  • Airflow Systems IAQ50 - page 11

    11 ON/OFF Key Press the ON/OF F key to turn the in- strument on and off. When the instru- ment is first turned on, it g oes through a preprogrammed power-up sequence that includes an internal se lf-check (when all display able items ar e shown). The Model IAQ50 begins by displaying percentage of battery life remaining (accurate for alkaline bat ter ...

  • Airflow Systems IAQ50 - page 12

    12 rameter, press the CO 2 key. Then, place the probe in the location you w ant to measure gas concentration. TEMP Key The meter will always d isplay tempera- ture readings from the permanent sensor on the lower line of the display. When you wish to take an external tempera- ture reading using an RTD probe, plug any three-pronged RTD probe into the ...

  • Airflow Systems IAQ50 - page 13

    13 HUMID Key Press HUMID to toggle between %RH, dew point or wet bulb, (as display ed on the top line of the display). Dew point and wet bulb are disp layed in the same units chosen for temperature measure- ment. READ/ENTER Key This is a dual function key. It reads measurement samples and it can be used to accept a value or condition or to return t ...

  • Airflow Systems IAQ50 - page 14

    14 TIME LOG Key To set up the instrument so it automati- cally takes measurements, use the TIME LOG key. This allows you t o program a logging time and i nterval, and the meter will read and store measur ements that can be viewed later. Press the TIME LOG key. Use the 5 or 6 keys to select “ On ”. Press the ENTER key. “ LOG ” will light up ...

  • Airflow Systems IAQ50 - page 15

    15 sen, the instrument will sample continu- ously until it is either stopped manually, runs out of memory, or the batteries run out. If a number between 1 and 9999 is chosen, the instrument will take that number of samples and then stop stor- ing readings. The instrument will then return to a normal measuring mode. Press ENTER to start the automati ...

  • Airflow Systems IAQ50 - page 16

    16 NEXT TEST Key Press NEXT TEST to advance to the next test ID. If the current test ID does not have anything stored, it will not advance to the next test ID. The Model IAQ50 w ill automatically increment the test ID number under the following conditions: • turning off the Model IAQ5 0 (if there is stored data) • setting any data logging sampl ...

  • Airflow Systems IAQ50 - page 17

    17 Using CO 2 : %OA= (C R –C S ) / (C R –C O ) x 100% where %OA = Percentage of outside air C R = Concentration CO 2 of return air C S = Concentration CO 2 of supply air C O = Concentration CO 2 of outside air Using Temper ature: %OA= (T R -T S ) / (T R -T O ) x 100% where %OA = Percentage of outside air T R = Temperature of return air T S = Te ...

  • Airflow Systems IAQ50 - page 18

    18 IMPORTANT: Temperature reading s sh ould be taken at the Air Handling Unit only, since there may be components in the system that chang e the temperature that are not evident upon initial examination. Calculating Outside Air measurements by taking reading s at the supply air to a room will not give the correct answer. Reheat coils and chille r c ...

  • Airflow Systems IAQ50 - page 19

    19 Details on the procedure ar e as follows: Press the %OA key once to begin. To choose a measurement mode ( OA , SUPPLY, RETURN ), use the 5 or 6 keys. You may press TEMP or CO 2 at any tim e to move from calculatin g %OA from TEMP to CO 2 or from CO 2 to TEMP. In return air mode, “ RETURN ” will appear on the di splay. The current va lue will ...

  • Airflow Systems IAQ50 - page 20

    20 If the measurement is not acceptable or the value is not yet stable, wait a minute and then take another reading to over - write the value on the top line. Once the top line value is acceptable, press the 5 or 6 keys to move the icon to either Supply or %OA, whichever reading you are prepared t o make next. Repeat the procedure with both a Sup- ...

  • Airflow Systems IAQ50 - page 21

    21 Note: “Err” will display if not enough information is available or a negative % value is calculated. To make changes to one of the other three readings without putting these values to memory yet, press the 5 or 6 keys to review the values and press READ/ENTER to overwrite the value. To exit this procedure completely with- out putting any val ...

  • Airflow Systems IAQ50 - page 22

    22 to change the value. Press ENTER to return to normal measurin g mode. RECALL Key The RECALL key lets yo u review data from a partic ular test ID . Press the RECALL key. The most curren t test ID number will show on the display. Press ENTER to review me asurements in this test ID, or use the 5 or 6 keys to choose another test ID to review. If das ...

  • Airflow Systems IAQ50 - page 23

    23 ments, press the desired measurement button. For example, if you wish to see humidity measurements, press HUMID . Press HUMID again to see d ew point readings. For the external RTD, press the TEMP key. If there is no data for that measurement type “- ----” will be dis- played. Press another meas urement key to view more data or press ENTER t ...

  • Airflow Systems IAQ50 - page 24

    24 them. Use the 5 or 6 key to adj ust the value, and press ENTE R to accept. DEL Key The Model IAQ50 lets yo u clear the last sample stored or the entire contents of memory. To clear only the last sample, hold the DEL key and the disp lay will begin a countdown from 3 to 0. Release the key befor e 0 is display ed. The display wil l beep twice and ...

  • Airflow Systems IAQ50 - page 25

    25 Printing Data Using the Optional MicroPrinter If the optional MicroPrinter is connected, what is viewed on-screen will be on the paper printout. Note : In order to print, the b aud rate on the Model IAQ50 must be set to the sa me as the printer. The default is 1200. The data will print in a format such as 12,345.67. If you desire, the Model IAQ5 ...

  • Airflow Systems IAQ50 - page 26

    26 printer, please refer to the operation and service manual for the printer to properly set the printer’s DIP switch settings. If the printer prints question marks (??????), asterisks (******), or r andom characters, reset it by turn ing it off an d then on again. If necessary, refer to the Owner’s Manual for the MicroPrinter. SECTION 5 Mainte ...

  • Airflow Systems IAQ50 - page 27

    27 Cases If the instrument case or storage case needs cleaning, wipe it o ff with a soft cloth. Never submerge the Model IAQ50 in any liquid. Storage When storing the Model IAQ50 for more than a month, TSI recommends removing the batteries. This prevents possible damage due to battery leak age. SECTION 6 Service and Calibration Please return your P ...

  • Airflow Systems IAQ50 - page 28

    28 calibration, Return Ma terial Authoriza tion (RMA) number, and shipping instructions. Please have th e following informat ion available when you call : • Owner’s name, address, and phone number • Billing address, if different and applicable • Instrument name and model • Serial number • Date of purchase • Where purchased TSI recomme ...

  • Airflow Systems IAQ50 - page 29

    29 especially important in applications where strict calibration records must be main- tained. Send the instrument to TSI Instruments Ltd. prepaid. Securely pack age your instrument in a strong cont ainer sur- rounded by at least 5 cm of suitable shock- absorbing material. Inc lude a purch ase order that clearly shows the instrument model number an ...

  • Airflow Systems IAQ50 - page 30

    30 3. Turn the IAQ50 on. It will flash “CAL” on the top row and beep intermit- tently. 4. Press and hold the CO 2 key to begin the calibration procedure. The display will begin a co untdown from 5 to 0. Release the key when the display reads 0. If the key is released too soon or too late, the instrument will go back to beeping and flashing “C ...

  • Airflow Systems IAQ50 - page 31

    31 the display indicates “SPAN” and the span concentration. 9. Install the regulator on the span calibration cylinder and co nnect tub- ing from the regulator to the inlet fit- ting on the calibration collar. 10. Use 5 and 6 keys to adjust the concentration displa yed on the IAQ50 to match the concentration on the span gas cylinder. 11. Press a ...

  • Airflow Systems IAQ50 - page 32

    32 Temperature and Humidity Calibrations Adjustment Procedure The temperature adjustme nt can add or subtract a number of degr ees. The range is ±9.99ºF (±5. 55°C). Calib ration can be done in either ºF or ºC mode. H umidity adjust- ment adds or subtract s a constant percent- age. The range is ±12. 0% relative humidity. The procedure for fie ...

  • Airflow Systems IAQ50 - page 33

    33 it. When finished, turn the instrument o ff and flip DIP sw itch #7 to “off.” On the Model IAQ50, press and hold the TEMP or HUMIDITY key to enter the calibration m ode for that p arameter. To enter the calibration mode for the RTD, make sure the RTD is plugged in. Press the TEMP key until “Prb” shows on the display, then press and hold ...

  • Airflow Systems IAQ50 - page 34

    34 SECTION 7 Troubleshooting Table 7-1 lists the symptoms, possible causes, and recommended solutions for common problems encountered with the Model IAQ50. If your symptom is not listed, or if none of the corrective a ctions solve your problem, plea se contact TSI Instruments Ltd. Table 7-1: Troubleshooting the Model IAQ50 Symptom Possible Causes C ...

  • Airflow Systems IAQ50 - page 35

    35 Symptom Possible Causes Correcti ve Action Display reads "LO" Wrong AC adapter Replace with the correct AC adapter. Low AC line voltage Correct the AC line voltage or use batteries. Dirty battery contacts Clean the battery contacts. Display reads “CAL” The Model IAQ50 has detected an internal fault Return to factory for service. Di ...

  • Airflow Systems IAQ50 - page 36

    36 Symptom Possible Causes Correcti ve Action Display reads “LOG FULL” You are trying to enter more readings than memory can handle Read or record the average; clear the sample register and proceed. Display flashes “Libatt” Low lithium battery power Return to factory for replacement. SECTION 8 DIP Switch Settings To access the DIP switches, ...

  • Airflow Systems IAQ50 - page 37

    37 Table 8-1: DIP Switch Settings Switch OFF ON 1-3 Must be OFF ------- 4 Not assigned ------- 5 °F °C 6 Buzzer OFF Buzzer ON 7 Normal Mode Calibrate Mode 8 American Date Format and 12,345.67 European Date Format and 12.345,67 The ON position is away from the batteries and OFF is towards the bat teries. Always leave DIP switch #1– 4 in the OFF ...

  • Airflow Systems IAQ50 - page 38

    38 Specifications Specifications are subject to change w ithout notice. CO 2 Range: 0 to 5000 ppm Accuracy: 1 ±3% of reading at 25 o C or ± 50 ppm, whichever is greater Resolution: 1 ppm Sensor Type Dual wavelength NDIR (Non-dispersive Infrared) Temperature: Range: 0 to 60 ° C Accuracy: ± 0.6 ° C Resolution: 0.1 ° C Secondary Tempera ture Pro ...

  • Airflow Systems IAQ50 - page 39

    39 Wet Bulb: Range: 5 to 60°C Resolution: 0.1 ° C % Outside Air: Range: 0 to 100% Resolution: 0.1% Logging Capability: Up to 14,000 meas ure- ments in 1000 test ID’s Intervals: 5,6,7, 8,9,10,15,20, 25, 30 sec. 1,2,3,4, 5,6,7,8,9,10,15, 20,25,30,60 m in. Meter Dimensions: 89 mm × 168 mm × 41 mm Weight (with ba tteries): 0.53 kg Probe length: 1 ...

  • Airflow Systems IAQ50 - page 40

    TSI Instruments Ltd . October 2005 Lancaster Road Printed in USA Cressex Business Park Part No. 1980533, Rev. A High Wycombe Buckinghamshire Tel: +44 (0) 149 4 459200 HP12 3QP England Fax: +44 (0) 149 4 459700 E-mail: info@airflow inst ruments.co.u k Copyright © 2005 Web: w ww.airflowinstr uments.co .uk TSI Incorporated ...

メーカー Airflow Systems カテゴリー Carbon Monoxide Alarm

Airflow Systems IAQ50のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IAQ50の取扱説明書
- Airflow Systemsの製品カード
- パンフレット
- またはAirflow Systems IAQ50の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Airflow Systems IAQ50の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Airflow Systems IAQ50の取り付け説明書、サービスマニュアル、簡易説明書、またはAirflow Systems IAQ50のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Airflow Systems IAQ50の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Airflow Systems IAQ50デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAirflow Systems IAQ50を使用するのを助ける技術的文書のことです。説明書は通常、全てのAirflow Systems IAQ50ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Airflow Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Airflow Systems IAQ50の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAirflow Systems IAQ50の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Airflow Systems IAQ50に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Airflow Systems IAQ50デバイスの基本機能を使うにあたってのヒント。 Airflow Systems IAQ50のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Airflow Systems IAQ50に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAirflow Systems IAQ50のメーカー/サービスへの連絡先に関する情報。

Airflow Systems IAQ50についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAirflow Systems IAQ50の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAirflow Systems IAQ50で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)