    1 Customer Care Department • The Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www.cda.eu Passionate about style EVPK90 Linear Ex tractor Manual for Installation, Use and Maintenance ...

  • CDA EVPK90 - page 2

    2 Impor tant The manufacturer cannot be held responsible for injuries or losses caused by inc orrect use or installation of this product. Please note that the manufacturer reserves the right to invalidat e the guarantee supplied with this product following incorr ect installation or misuse of the appliance or use in a commercial en vironment. This ...

  • CDA EVPK90 - page 3

    3 Using your Extractor For best performance, y ou should switch on the extractor 15 minutes before starting to cook and leave it to run f or approximately 15 minutes after the end of cooking. Control P anel A - Light key B - Decrease speed key C - Display D - Increase speed key E - Timer key T o switch the ex tractor light on and o • T ouch ke ...

  • CDA EVPK90 - page 4

    4 Care and Maintenanc e IMPORT ANT : DO NO T PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWIT CHING OFF THE ELECTRICIT Y SUPPL Y . Cleaning Y ou should use a nonabrasive cleaner . Any abrasive cleaner (including Cif ) will scratch the surface and could erase the control panel markings. Y ou can clean your extrac tor eectively ...

  • CDA EVPK90 - page 5

    5 Fig . 3 Care and Maintenanc e Changing the charcoal lter (r e -circulating only) When the display ashes alternating the speed selected with the letter F , the charcoal lters must be replac ed. After the charcoal lter has been replac ed, the electronic memory must be reset by touching key A for approxima tely ve seconds, until the l ...

  • CDA EVPK90 - page 6

    6 Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIA TEL Y AFTER USE AS THE BULB WILL BE HOT . ALLOW IT TO C OOL BEFORE REMOVING IT . Using a at blade screwdriv er , carefully prise o the lamp cover as shown in gure 4. Remove the bulb and replac e with a 12V 20W halogen light bulb. Finally , replace the ligh t bulb cover . Do not touc ...

  • CDA EVPK90 - page 7

    7 DOUBLE POLE SWITCHED FUSE SPUR OUTLET USE A 3 AMP FUSE Mains Electr icity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE. We r ecommend that the appliance is connected by a qualied electrician, who is a member of ...

  • CDA EVPK90 - page 8

    8 Electrical I nformation Mains electrical voltage: 230 – 240V ac, 50Hz T otal rated power consumption: 330W T roubleshooting If your extractor is not working: 1. Check that the mains supply has not been switched o . 2. Check that the fuse in the spur has not blown. ...

  • CDA EVPK90 - page 9

    9 Mounting your Extractor IMPORT ANT : The extractor is intended to be mounted directly to the ceiling using xings appropriate for the ceiling . Ensure that there is adequat e ceiling strength and supports at the xing points; if in doubt, consult a joiner or electrician. When the extractor is to be installed above an electric hob, the minimum ...

  • CDA EVPK90 - page 10

    10 Installation Note: We r ecommend that you seek the help of another individual when installing this product. Preparing the extractor The electronic control bo x and ventilation pipe need to be tted to the motor body bef ore proceeding with the install. T o connec t the electronic control bo x, proceed as shown below using screw s (G) (gs 7, ...

  • CDA EVPK90 - page 11

    11 Installation Assembling the extractor ready for mounting: 1. Place the extractor body on a table and x the support sec tions (D) using the supplied screws (E) as shown in g 11 below . 2. Remove the screws(A ) fastening the lower and upper(B) support sections as shown in g 12 below . 3. Measure the height of the ceiling and then the hotp ...

  • CDA EVPK90 - page 12

    12 Installation Assembling the extractor ready for mounting: 4. Assemble the upper (B) and lower (C) support sections at the desired height (as calculated in step 3) using the supplied scr ews (G) as shown in g 13. 5. When the support sections have been securely fastened together , t the upper(B) and lower(A) chimney sections over the support ...

  • CDA EVPK90 - page 13

    13 Installation Mounting the extractor to the ceiling: 1. Using the supplied template , drill four holes in the ceiling and t suitable wall plugs into the holes, if required . Note that plugs may not be required if the extractor is to be mounted directly to the ceiling joists. Ensure that the wall plugs used are suitable for the int ended purpos ...

  • CDA EVPK90 - page 14

    14 Installation Mounting the extractor to the ceiling: 4. Recirculating mode: If the extractor is to be used as a recirculation device, ltering the air before recycling into the kitchen then the vent diverter needs to be tted. Fit the div erter(M) to the upper suppor t section using screw (I) and connect the ventilation pipe (H). 5. Connect t ...

  • CDA EVPK90 - page 15

    15 DOUBLE POLE SWITCHED FUSE SPUR OUTLET USE A 3 AMP FUSE Mains Electr icity Connection THIS APPLIANCE MUST BE CONNECTED T O THE MAINS SUPPL Y BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE. We r ecommend that the appliance is connected by a qualied electrician, who is a member of ...

  • CDA EVPK90 - page 16

    16 NO TES: ...

  • CDA EVPK90 - page 17

    17 NO TES: ...

  • CDA EVPK90 - page 18

    18 NO TES: ...

  • CDA EVPK90 - page 19

    19 E & O E. All instructions, dimensions and illustrations are provided for guidance only . CD A reserve the right to change specifications without prior notice. Attribute Symbol Value Units Model Identification evpk90 Annual Energy Consumption AEC Hood 134.2 kWh Time increase factor f 1.4 Fluid Dynamic Efficiency FDE Hood 16.1 (D) Energy Effi ...

  • CDA EVPK90 - page 20

    20 Customer Care Department • The Group Ltd. • Harb y Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer .care@cda.eu W : www.cda.eu Passionate about style T o contact our Customer Car e Depar tment, or for Service, please contact us on the details below . ...

メーカー CDA カテゴリー Exhaust hood

CDA EVPK90のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EVPK90の取扱説明書
- CDAの製品カード
- パンフレット
- またはCDA EVPK90の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、CDA EVPK90の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、CDA EVPK90の取り付け説明書、サービスマニュアル、簡易説明書、またはCDA EVPK90のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、CDA EVPK90の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

CDA EVPK90デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCDA EVPK90を使用するのを助ける技術的文書のことです。説明書は通常、全てのCDA EVPK90ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

CDAの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. CDA EVPK90の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCDA EVPK90の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。CDA EVPK90に関してこのドキュメントで見つけることができる全てのヒントの目次
3. CDA EVPK90デバイスの基本機能を使うにあたってのヒント。 CDA EVPK90のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。CDA EVPK90に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCDA EVPK90のメーカー/サービスへの連絡先に関する情報。

CDA EVPK90についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCDA EVPK90の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCDA EVPK90で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)