Renesas H8S/2628 - page 1
2004.1.29 H8S/2628 Group FP-100B User System Interface Cable HS2628ECH61H User’s Manual Renesas Microcom puter Development Envi ronment System Rev.4.00 ...
-
Renesas H8S/2628 - page 2
Cautions Keep safety firs t in your circuit des igns! 1. Renesas Technology Corp. puts the maximum effort into making s emiconductor products better and more reliable, but there is always the poss ibility that trouble may occur with them. Trouble with se miconductors may lead to pers onal injury, fire or property damage. Remember to give due cons i ...
-
Renesas H8S/2628 - page 3
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attemp t to use the user system interface cable until you fully understand its mec h an is m. User Syst em Interf ace Ca ble: Throughout th is document, the term " ...
-
Renesas H8S/2628 - page 4
II LIMITED WARRANTY Renesas warrants its user s ystem interface cables to be manufactured in accordance with published specifications and free from d efects in mater ial and/or workmanship. Renesas will re pair or replace a n y user sy stem interface cables deter mined to be defective in mate rial and/or workmanship. User s ystem interface cables a ...
-
Renesas H8S/2628 - page 5
III State Law : Some states do not allo w the exclusion or limitatio n of i mpli ed warranties or liabilit y for incidental or consequential da mages, so the above limitatio n or exclusion may not apply to you. Thi s warr an t y give s yo u spec i fic le gal ri ght s, and you ma y ha ve ot her rig hts wh ic h ma y var y fro m state to state. The Wa ...
-
Renesas H8S/2628 - page 6
IV SAFETY PAGE READ FIRST • READ this user's manual before using this user system interface cable. • KEEP the user's manual handy for future reference. Do not attemp t to use the user system interface cable until you fully understand its mec h an is m. DEFINITION OF SI GNAL WORDS This is the safety alert sy mbol. It is u sed to al ert ...
-
Renesas H8S/2628 - page 7
V W ARNING Observe the pr ecautions listed b elow. Failure to do so will result in a FIRE H AZARD and will damage the user system and the emul ator product or will r esult in PERSONAL INJURY. The USER PROGRA M will be LOST. 1. Do not repair or remodel the emul ator product by yourself for elect ric shock pre vention and quality assur ance. 2. Alway ...
-
Renesas H8S/2628 - page 8
i Preface Thank y ou for purch asing this us er sys tem in terface cable (HS2628ECH61H) f or the Renes as’ origin al m icrocom puter H8S/ 2628 group. The HS2628ECH61H is a u ser sy stem interface cable th at connects an H8S/2628 group E6000 emu lator (HS 2628EPI61H; herein after ref erred to as the em ul ator) to the IC socket for an FP-100B pack ...
-
Renesas H8S/2628 - page 9
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User Sy stem In terface Cable to Em ulator Station .......................................... 3 2.2 Connect ...
-
Renesas H8S/2628 - page 10
1 Section 1 Configuration CAUTION Use an IC149-100- 054-B51 socket (manuf actured by YAMAICH I ELECTRONICS Co., Lt d.) for the FP- 100B package IC socket on the user syst em. Figure 1 s how s the conf iguration of the HS2628ECH 61H user sy stem interface cable f or the FP-100B packag e. User system IC socket Cable head Screws (M2.6 x 12 mm) with fl ...
-
Renesas H8S/2628 - page 11
2 Table 1 li s ts t h e HS 2628EC H61H com ponen t s. Pl eas e m ake su re you h ave all of t h es e com ponen ts when unpacking. Table 1 HS2628ECH61H Com p onents No. Component Quantity Remar ks 1 Cable body 1 Cable 2 Cable head 1 3 IC socket 1 For the FP-100B package 4 Socket cover 1 For installing an FP-100B packaged M CU 5 Screws (M 2.6 x 12 mm ...
-
Renesas H8S/2628 - page 12
3 Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user syst em ...
-
Renesas H8S/2628 - page 13
4 Emulator station E6000 Cable body connector User system interface cable Figure 2 Connecting User System Interface Cable to Em ulator Station ...
-
Renesas H8S/2628 - page 14
5 2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage ...
-
Renesas H8S/2628 - page 15
6 2.2.3 I nsertin g Cable Head CAUTION Check the location of pin 1 before inserting. Alig n pin 1 on the IC socket for an FP- 100B package on the us er syst em w ith pin 1 on the user sy stem interface cable h ead, and insert the u ser sy stem interface cable head in to the IC socket on the user system, as shown in figure 3. 2.2.4 Fas tening Cab le ...
-
Renesas H8S/2628 - page 16
7 Fasten th e user sy stem interf ace cable head to the IC sock et for an FP-100B pack age on the u ser system w ith the four scr ews (M2.6 x 12 m m; wi th fou r flat w ash ers) provided. Each screw sh ould be tighten ed a little at a tim e, alternating betw een s crew s on opposin g corn ers . Take special care, such as m anually securing the IC s ...
-
Renesas H8S/2628 - page 17
8 2.2.5 Fas tening Cab le Body Connect the cable body to the cable h ead. Cable body Cable head Remove jig Push two remove jigs. Removing User system Figure 4 Fastening Cable Body ...
-
Renesas H8S/2628 - page 18
9 2.3 Recomm ended Dimensions for User System Mount Pad Figure 5 sh ow s th e recom m en ded dim ension s f or th e m ount pad (footprint) for the user sys tem with an IC s ocket for an FP-100B packag e (IC149-100- 054-B51: m anuf actured by YA MAICHI ELECTRONICS C o., Ltd.). Note th at the dim ens ions in figu re 5 are somew h at differen t from t ...
-
Renesas H8S/2628 - page 19
10 2.4 Dimensions for User System Interface Cable Head The dimen sions for th e user sy stem interface cable h ead are show n in f igure 6. Unit: mm Tolerance: ±0.5 mm 63.5 63.5 17.0 17.0 29.5 29.5 Figure 6 Dim ensions for User System Interface Cable Head ...
-
Renesas H8S/2628 - page 20
11 2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dim ens ions, after con necting th e user sy stem interface cable head to th e user sy stem , are show n in figu re 7. 16.0 21.5 Cable head User system Unit: mm Tolerance: ±0.5 mm IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co. Ltd.) Figure ...
-
Renesas H8S/2628 - page 21
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0785 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the f orce required to turn th e screw becom ...
-
Renesas H8S/2628 - page 22
13 MCU Pin 1 IC socket (IC149-100-054-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2.6 x 6 mm) with flat washers Socket cover Figure 8 Installing M CU to User System ...
-
Renesas H8S/2628 - page 23
14 Section 4 Verifying Oper ation 1. Turn on the emu lator according to th e procedures described in the H8S Fam ily E6000 Em ul ator User' s Manu al (HS2000EPI61HE). 2. Verify the user sy stem in terface cable connections by accessing the external m emory and ports to check the bu s st ates of th e pins w ith th e MEMORY_FIL L com m an d (emu ...
-
Renesas H8S/2628 - page 24
15 Section 5 Notice 1. Make s ure that pin 1 on the user sy stem IC socket is correctly aligned w ith pin 1 on the cable head before insertin g the cable head in to the user sy stem IC socket. 2. The dimen s ion s of the recom m ended m oun t pad f or th e u s er sy stem IC s ocket are dif ferent f rom those of the MCU. 3. This user sy stem interf ...
-
Renesas H8S/2628 - page 25
H8S/2628 Group FP-100B User System Interface Cable HS2628ECH61H User's Manual Publication Date: Rev.4.00, January 29, 2004 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co., Ltd. 2004 Renesas Technology Corp. All rights rese ...
-
Renesas H8S/2628 - page 26
H8S/26 28 Gr oup F P-100B User Sy stem Inte rface C able HS2628E C H61H U ser’ s Manual REJ10B0084-0400H ...
Renesas H8S/2628についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもRenesas H8S/2628の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがRenesas H8S/2628で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。