    Part No. 302403-B Rev 00 January 1999 Installing Media Dependent Adapter s (MD A) s 302403-B.m kr Page -1 Friday, Januar y 15, 1999 2:56 PM ...

  • Bay Networks 302403-B - page 2

    © 19 99 by Bay Net works, In c. All righ ts re s e rved. T r adema rk s Bay Networks is a registered t rademark and BayStack is a trademar k of Bay Networks, Inc. All other trademarks and registered trademarks are pr operty of their respecti ve o wners. Stat em en t of Con di tio ns In the interes t of impr oving internal design, ope ration al fun ...

  • Bay Networks 302403-B - page 3

    1 Intr od uction Thi s document pr o v i des proced ures for i nst alli n g opt ion al pl ug -i n m ed ia de pe nde n t ada p ter s (M D A s) into su pp o rte d Bay Net work s prod ucts equipped with an e xpan sion s lot. The MD As can suppor t high-speed connections to serv ers, shared F ast Ethern et hub s, or backb one de vic es. The fo llo w in ...

  • Bay Networks 302403-B - page 4

    2 B a y N etwo rks is co ns tantl y a d di ng new mod els and feat ur es to e xis tin g p rod uct li ne s ; se e you r Ba y Net work s sales representati v e f or a full range of a v ailabl e MD As. F or mo re de tails, see yo ur swit ch produ ct us er’ s gu ide. The fo llo wi ng Bay Net wor ks product s are suppo rted: • BayS tack 3 50 Seri es ...

  • Bay Networks 302403-B - page 5

    3 Figure 1. 400-4 TX MD A F ro nt P anel T able 1. 400-4 TX MD A Compon ents It e m Label Description 1 100 100BASE -TX port status LEDs (green): On: T he corresponding port is set to operate at 100 Mb/s . Of f: The link connection is bad o r there is no connection to this p ort. Blinking: The corres ponding port is manage ment disabled. (continued ...

  • Bay Networks 302403-B - page 6

    4 The RJ-4 5 ports are co nf igu red as media-dep endent interf ace-crosso v er (MDI- X ) connectors. These ports connect o v er straight cables to the netwo rk interf ace controller (NIC) card in a n ode or s erv er , similar to a 2 10 10BASE-T por t s tatus LEDs (green): On: T he corresponding por t is set to oper ate at 10 Mb/s . Off: The link c ...

  • Bay Networks 302403-B - page 7

    5 con ve ntional Ethernet r epeater hub . If you ar e con necting to anothe r Ether net hub o r Ether net switch , yo u need a crosso v er cable unless an MDI connection ex ists on the associated port of the attached de vice. The 40 0-4TX MD A can operate at either 10 Mb/s or 100 Mb/s . The speed is determ ined throu gh auton egotiation with it s c ...

  • Bay Networks 302403-B - page 8

    6 W arning: F iber op tic equ ipment c an emit laser o r infrared light t hat can injure your e yes. Ne ver look into an op tical f iber or connec tor port. Alw ays assum e that f iber o ptic cab les are co nnect ed t o a ligh t so urce. V or sic ht: G la sf ase rk om pone n ten kö nnen L aser lich t bz w . I nfrarotlicht abstrah len, wodurc h Ihr ...

  • Bay Networks 302403-B - page 9

    7 Ad vertencia: L o s equ ipo s de f ibra ó pt i ca pued en emitir radia cione s de l áser o in frarrojas q ue pu eden dañar los ojo s. No mi re nun ca en el in ter ior de un a f i bra óp tica ni d e un pu erto de c one xión. Su pong a siemp re que lo s cab les de fibra ópti ca está n conect ados a una fuent e l uminosa . A vvertenza: Le app ...

  • Bay Networks 302403-B - page 10

    8 Figure 2. 100B ASE-FX MD A Fr ont P a nels Ta b l e 2 describes the 100B ASE-FX comp onents an d LEDs. F or install at ion in structions , see “ I nstal ling an MD A ” on pag e 17 . RX TX 100BASE-FX RX TX 100BASE-FX Activity Link F Dx 400-2FX MDA BS45043A 3 4 2 1 Activity Link F Dx 400-4FX MDA 3 4 2 1 302403-B.m kr P age 8 F riday, January 15 ...

  • Bay Networks 302403-B - page 11

    9 T able 2. 100B ASE-FX MD A Co mponen ts Item La bel Des cription 1 Link Communications link LEDs (green): On: V alid communi cations link estab lished. Off: The communications link connection is bad or there is no connection to this por t. Blinking: The corres ponding por t i s manage ment disab led. 2 F Dx Full-duple x por t status LEDs (g reen) ...

  • Bay Networks 302403-B - page 12

    10 1000 B ASE-S X MD As There are two 10 00B ASE-SX (shortw a v e gigabit) MD A model s: • The 450-1 SR MD A is a single M A C MD A with a separa te redu ndan t Ph y (backup Ph y port). Only one Phy p ort can be acti v e at any time. If the acti v e Phy port fails, the red u ndant P hy port autom atically becomes the acti v e port. • The 450-1 ...

  • Bay Networks 302403-B - page 13

    11 Figure 3. 1000 B ASE-S X MD A Fr ont P a nels Ta b l e 3 describes the 1000 B ASE-SX com pon ents and LEDs. F or install at ion in structions , see “ I nstal ling an MD A ” on pag e 17 . 1000BASE-SX TX RX Phy Link Activity 450-1SX MDA TX RX 1000BASE-SX RX 1000BASE-SX TX Activity Link Phy Select 450-1SR MDA 3 BS45044A 4 3 4 450-1SR MDA (1-por ...

  • Bay Networks 302403-B - page 14

    12 T able 3 . 1 000 B ASE-SX MD A Components Item La bel Des cription 1 Link Communication link LEDs (green): On: V alid comm unications link. Off: The communi cations link connection is bad or there is no connection to this por t. Blinking: The corresp onding por t is management disabled. 2P h y (or) Ph y Select Ph y status LE Ds (green): On: T he ...

  • Bay Networks 302403-B - page 15

    13 1000 B ASE-LX MD As There are two 10 00B ASE-LX (l ongw a ve gi gabi t) MD A model s: • The 450-1 LR MD A is a single MA C MD A with a separa te redu ndan t Ph y (backup Ph y port). Only one Phy p ort can be acti v e at any time. If the acti v e Phy port fails, the red u ndant P hy port autom atically becomes the acti v e port. • The 45 0-1L ...

  • Bay Networks 302403-B - page 16

    14 Figure 4. 1000 B ASE-L X MD A Fr ont P anels Ta b l e 4 describes the 1000 B ASE-L X MD A compon ents and LEDs . F or install at ion in structions , see “ I nstal ling an MD A ” on pag e 17 . 1000BASE-LX TX RX Phy Link Activity 450-1LX MDA BS45045A 3 4 2 1 TX RX 1000BASE-LX RX 1000BASE-LX TX Activity Link Phy Select 450-1LR MDA 3 4 2 1 450-1 ...

  • Bay Networks 302403-B - page 17

    15 T able 4. 1000 B ASE-LX MD A Compone nts Item La bel Des cription 1 Link Communication link LEDs (green): On: V alid comm unications link. Off: The communi cations link connection is bad or there is no connection to this por t. Blinking: The corresp onding por t is management disabled. 2P H Y (or) Ph y Select Ph y status LE Ds (green): On: T he ...

  • Bay Networks 302403-B - page 18

    16 1000B ASE -LX Multimode Appli cations F or 1000 B ASE-LX multim ode app lications, the lo ngwa ve gig ab it tr anscei v ers must be mode c ond iti one d e xterna lly via a special of fset SMF/MMF patch cord. The o f fset SMF/MMF patch cord allo w s the same transcei ver to b e used fo r both mu ltim ode an d si ng le-m ode f iber . See yo ur Bay ...

  • Bay Networks 302403-B - page 19

    17 Inst alling an MD A The Uplin k Mo dule slot on the B ayS tack 4 50 sw itches accommod ates a sing le MD A. The co nnection can be either an RJ- 45 10/ 100B ASE-TX MD A or a f i be r (100 B ASE-FX or 100 0B ASE-SX/ LX) MD A with an S C or MT -RJ connector . T o in stall an MD A into the Uplin k Mo dule slot , follo w these steps: 1. Unplug the A ...

  • Bay Networks 302403-B - page 20

    18 3. Insert the MD A into the chassis s lot (see Figur e 5 ) tak ing car e to slide the MD A onto the guides pr ovided on the chassis. Figure 5. I nstalling an MD A 4. Pr ess the M D A fi rm ly in to th e cha ssi s slot . Be su r e tha t the MD A is f ully seated into the mating connector . 5. Secure the MD A in the chassi s by tightening the thum ...

  • Bay Networks 302403-B - page 21

    19 After connecting the port cables, conti nue to follo w th e instructions in that manual to co nnect po wer and v erify the installat ion . Replacing an M D A with a Di ff erent Model When replacing an in stalled MD A with ano ther type of MD A, co mplete the follo wing steps to clear the switch NVRAM: 1. P o wer down the switch. Remo v e the A C ...

メーカー Bay Networks カテゴリー Network Card

Bay Networks 302403-Bのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 302403-Bの取扱説明書
- Bay Networksの製品カード
- パンフレット
- またはBay Networks 302403-Bの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bay Networks 302403-Bの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bay Networks 302403-Bの取り付け説明書、サービスマニュアル、簡易説明書、またはBay Networks 302403-Bのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bay Networks 302403-Bの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bay Networks 302403-Bデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBay Networks 302403-Bを使用するのを助ける技術的文書のことです。説明書は通常、全てのBay Networks 302403-Bユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bay Networksの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bay Networks 302403-Bの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBay Networks 302403-Bの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bay Networks 302403-Bに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bay Networks 302403-Bデバイスの基本機能を使うにあたってのヒント。 Bay Networks 302403-Bのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bay Networks 302403-Bに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBay Networks 302403-Bのメーカー/サービスへの連絡先に関する情報。

Bay Networks 302403-Bについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBay Networks 302403-Bの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBay Networks 302403-Bで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)