Nordyne T3BNの取扱説明書

16ページ 0.46 mb
ダウンロード

ページに移動 of 16

Summary
  • Nordyne T3BN - page 1

    Outdoor Heat Pump User’ s Inf ormation and Installation Instructions T3BN Series High Effi ciency Commer cial Split System These instructions are pr imarily intended to assist qualifi ed individuals e xpe- rienced in the proper installation of heating and/or air conditioning appliances. Some local codes require licensed installation/ser vice pe ...

  • Nordyne T3BN - page 2

    2 2. Set the ther mostat temper ature to the desired temperature le v el using the temperature selector . Please ref er to the separate detailed thermostat user’ s manual f or complete instructions regarding ther mostat prog ramming. The outdoor unit and indoor blo wer will both cycle on and off to maintain the indoor temperature at the desired h ...

  • Nordyne T3BN - page 3

    3 T O MAINT AIN Y OUR HEA T PUMP— CA UTION: Be certain the electrical power to the outdoor unit and the furnace/air handler is disconnected before doing the follo wing recommended maintenance. 1. Regularly: a. Clean or replace the indoor air fi lter at the star t of each heating and cooling season, and when an accumulation of dust and dir t is v ...

  • Nordyne T3BN - page 4

    4 Read Y our W arranty Please read the separate w arranty document completely . It contains v aluable inf ormation about your system. GENERAL INFORMA TION Read the f ollowing instructions completely before perf or ming the installation. Outdoor Unit Section — Each outdoor unit is shipped with a refrigerant holding charge. NO TE: DO NO T USE ANY P ...

  • Nordyne T3BN - page 5

    5 The maximum recommended interconnecting refrigerant line length is 75 f eet, and the v er tical elev ation diff erence between the indoor and outdoor sections should not e xceed 20 f eet. Consult long line application guide for installations in e xcess of these limits. Filter Dryer Installation — A fi lter dryer is provided with the unit and i ...

  • Nordyne T3BN - page 6

    6 Electrical P ower Wiring — Electr ical po wer wiring must comply with the current provisions of the “National Electrical Code” (ANSI/NFP A 70) and with applicable local codes ha ving jurisdiction. Use of rain tight conduit is recommended. Electr ical conductors shall ha ve minimum circuit ampacity in compliance with the outdoor unit rating ...

  • Nordyne T3BN - page 7

    7 GR W 2 CE O Y Thermostat R Air Handler Heat Pump OD Section T ypical Heat Pump with Standar d Air Handler O NO TE: Jumper between W2 and E is required when no OD T -Stat is used. C & W2 to be connected to Electric Heat. Y W 2 C R Y O C G W 2 W 1 ...

  • Nordyne T3BN - page 8

    8 Indoor Blower — Set the thermostat function s witch to COOLING and the fan s witch to ON. V erify that the indoor blo wer is operating and that airfl ow is not restricted. Set the f an s witch back to A UT O . Low-Pressure Switc h — A low-pressure s witch is f actor y-installed (see attached). This s witch is located in the suction line inte ...

  • Nordyne T3BN - page 9

    9 2. Jumper the “T2”-”DFT” test pins. This will indicate to the board that the defrost T -stat is closed(if the compressor is running). Defrost T -stat is closed at 32° or below and is open at 68° or abov e. But it’ s state is unknown if the temper ature is between 32°F and 68°F . The defrost ther mostat tells the board whether a defr ...

  • Nordyne T3BN - page 10

    10 Refrigerant Charging Charts 7.5 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature (F) Liquid Pressure (psig) Add refrigerant w hen below curve Remove refrigerant w hen above curve ...

  • Nordyne T3BN - page 11

    11 Refrigerant Charging Charts 10 Ton HP TXV Charging Chart 150 175 200 225 250 275 300 325 350 375 400 75 80 85 90 95 100 105 110 115 120 125 130 135 Liquid Temperature (F) Liquid Pressure (psig) Add refrigerant w hen below curv e Remove refrigerant w hen above curve ...

  • Nordyne T3BN - page 12

    12 REFRIGERANT CHARGING CHAR T Heating Mode of Operation PR OCEDURE FOR CHARGING 10-T ON HEA T PUMP IN HEA TING MODE. 1. Ev acuate the refr igerant system. 2. Charge the system by w eighing in 30 lbs R-22 refrigerant. This is the recommended charge for 5/8 inch 15 f oot line set. F or line sets other than 15 feet add 9.0 oz. R-22 per additional 5 f ...

  • Nordyne T3BN - page 13

    13 RELA Y 4 2 3 1 6 5 T1 T2 T3 CCH C S R T1 T2 C Y O W2 R DFT DF1 DF2 E DEFROST CONTROL BOARD CY O W 2 R E L3 L2 L1 GRD REV VA LVE DFT LOW PRESSURE SWITCH THREE PHASE FIELD SUPPL Y CAP ACITOR CONT ACTOR OUTDOOR F AN MOTO R COMPRESSOR HIGH PRESSURE SWITCH T1 L1 L2 L3 T2 T3 ORANGE GRA Y BLACK HARNESS RED HARNESS GRA Y YELLOW HARNESS BLACK BLACK BLACK ...

  • Nordyne T3BN - page 14

    14 A CCESSORIES — Condensing Unit Low Ambient Kit 913549A- Maintains system pressures during low ambient conditions. PHYSICAL AND ELECTRICAL SPECIFICA TIONS / OUTDOOR UNITS 10.1 EER —High Effi ciency — Three Phase COPPER WIRE SIZE — A WG (1% V oltage Dr op) Supply Wire Length-Feet Supply Cir cuit 200 150 100 50 Ampacity 6 8 10 14 15 468 1 ...

  • Nordyne T3BN - page 15

    15 ...

  • Nordyne T3BN - page 16

    INST ALLER: PLEASE LEA VE THESE INST ALLA TION INSTRUCTIONS WITH THE HOMEO WNER ¢708538G¤ 708538A 708538A (replaces 7085380) Specifi cations and illustr ations subject to change without notice and without incurring obligations. Printed in U.S .A. (08/08) ...

メーカー Nordyne カテゴリー Heat Pump

Nordyne T3BNのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- T3BNの取扱説明書
- Nordyneの製品カード
- パンフレット
- またはNordyne T3BNの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Nordyne T3BNの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Nordyne T3BNの取り付け説明書、サービスマニュアル、簡易説明書、またはNordyne T3BNのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Nordyne T3BNの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Nordyne T3BNデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNordyne T3BNを使用するのを助ける技術的文書のことです。説明書は通常、全てのNordyne T3BNユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Nordyneの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Nordyne T3BNの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNordyne T3BNの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Nordyne T3BNに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Nordyne T3BNデバイスの基本機能を使うにあたってのヒント。 Nordyne T3BNのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Nordyne T3BNに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNordyne T3BNのメーカー/サービスへの連絡先に関する情報。

Nordyne T3BNについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNordyne T3BNの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNordyne T3BNで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)