    V enezia Z VE-E3 0S Z VE-E3 6S Z VE-E42S Model number: Serial number: Use, Care, and Installation Guide MAY07.0101 © Zeph yr Corporation. www .zephyronline.com ...

  • Zephyr ZVE-E42S - page 2

    www .zephyronline.com ...

  • Zephyr ZVE-E42S - page 3

    T able of Contents 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting .................................................................. Specific ...

  • Zephyr ZVE-E42S - page 4

    www .zephyronline.com Im p or tan t s afet y N ot i c e 2 T O RE DUC E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T US E T H IS FAN W ITH ANY S O L ID- S T ATE SP E E D C O NTRO L D EV I C E. TO R E DUC E T H E R I S K O F F I R E, E L E C T R I C S H O C K, O R INJ U R Y TO P E R SON S, O B S E RVE T H E F O L LO W I N G: a. Use ...

  • Zephyr ZVE-E42S - page 5

    List of Materials 3 1 - Hood 2 - Metallic lters (3 - ZVE-E3 6, E42) 2 - Halogen light bulbs (4 - ZVE-E3 6, E42) 1 - Duct cover assembly (2 pieces) 1 - Hardware bag 1 - Duct cover mounting bracket 1 - Pac ket of mounting screws w/anchors 1 - Buttery damper NO DUC T I NG IS INCLUDED * Note: Zephyr recommends using 5 0LB E Z anchors if mounting ...

  • Zephyr ZVE-E42S - page 6

    www .zephyronline.com 4 Installation - Ductwork Calculation Sheet Duct pieces To t a l Equivalent number length x used = 3 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 elbow 15 Ft . x ( ) = Ft. 3 1/ 4” x 10” Rect. 45 0 elbow 9 Ft. x ( ) = Ft. 3 1/ 4” x 10” Rect. 90 0 ? ...

  • Zephyr ZVE-E42S - page 7

    5 - n o i t a l l a t s n I e c n a r a e l C & t h g i e H g n i t n u o M DUC T ING min. ducted - 32 1/2” min recirc. - 36” max. 51” *m i n . 9 7 " * * ma x. 123" 36" 9 -27/32" mi n . 2 8" - max . 3 6" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount hei ...

  • Zephyr ZVE-E42S - page 8

    www .zephyronline.com 6 Installation - Ducting W AR NING F IRE HA ZA RD N EVE R exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling,attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal s ...

  • Zephyr ZVE-E42S - page 9

    7 - n o i t a l l a t s n I s n o i t a c i f i c e p S 6.5" 6" 10.37" 13.87" 2.78" 1.87" 0.5" 3/4" Elec. K.O. Cable Lock All Electrical work must by performed by qualied electrician or person with similar technical know how and backgr ound. F or personal safety , remove house fuse or open circuit breaker ...

  • Zephyr ZVE-E42S - page 10

    www .zephyronline.com 8 - n o i t a l l a t s n I r e v o C t c u D & d o o H e h t g n i t n u o M 1. Measure from range top to hood bottom (28” min) Level and mark line A. 2. Plum and mark center line. 3. Mark mounting height line B. (10-3/8” from line A) 4. Mark mounting spread from C/ L (9-7 /16”) 5. Fasten E-Z anc hors to wall (see b ...

  • Zephyr ZVE-E42S - page 11

    9 Installation - Ductless Recirculating Ductless recirculating i s intended for applications where an exhaust duct work is not possible to be installed. W hen converted, the hood functions as a "purifying" hood rather than an exhaust hood. Fumes and e xhaust from cooking is drawn and ltered by a set of optional charcoal lters. The a ...

  • Zephyr ZVE-E42S - page 12

    www .zephyronline.com 10 F eatures & Controls - T ouc h Controls & F eatures The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blo wer eciency . If improperly maintained, residue from cooking will sift though lters and cause damage to hood blowers and other sensitive components; a ...

  • Zephyr ZVE-E42S - page 13

    11 F eatures & Controls - Charcoal Filters Change Indicator Filter Change Reminder (Charcoal, if tted): W hen your hood is installed as a ' Recirculating' (Ductless) unit, it is tted with a set of Charcoal Filters to purify e xhaust and fumes from cooking, then re-circulate the air within the home.These Charcoal Filters are requ ...

  • Zephyr ZVE-E42S - page 14

    www .zephyronline.com 12 F eatures & Controls - Metal Filters Clean Indicator Filter Clean Reminder (Standard Metal Filters tted): W hether your hood is installed as an Exhaust or Purifying unit, a set of metal lters are tted by the factory . These Metal Filters are intended to lter out residue from cooking. They need not be replace ...

  • Zephyr ZVE-E42S - page 15

    13 Maintenance - Cleaning Surface Maintenance: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratc h and damage surface. F or heavier soil use liquid degreaser. After cleaning, you may use non-abrasive stainless steel polish/ cleaners, to polish a ...

  • Zephyr ZVE-E42S - page 16

    www .zephyronline.com 14 Maintenance - Lights Replacing Light Bulbs CA UTI O N: Light bulb becomes extremely hot when turned on. DO NO T touch bulb until switched o and cooled. T ouc hing hot bulbs could cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove by turning bulb counter clockwise. If bulbs are dicult ...

  • Zephyr ZVE-E42S - page 17

    15 T rouble Shooting After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Metal lter is vibrating. 1. The power source is not turned ON. 2. The power line and the cable loc king connector is not connecting pr ...

  • Zephyr ZVE-E42S - page 18

    List of Parts and A ccessories 16 Light Bulb (J D R-E27) Z0B-0011 Metallic Filters (2 pk) Z0F-M042 Metallic Filters (3 pk) Z0F-M043 T elescopic Back Splash 30” Z0S-0013 T elescopic Back Splash 36” Z0S-0016 T elescopic Back Splash 42” Z0S-0012 W ire Spice Rack 30” Z0R-0013 W ire Spice Rack 36” Z0R-0016 W ire Spice Rack 42” Z0R-0012 T o o ...

  • Zephyr ZVE-E42S - page 19

    www.zephyronline.com Warranty One Y ear Service R epair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. O n e Y ear Parts W arranty: F or one year from date of original purchase, we will provide free of charge, nonconsumabl ...

メーカー Zephyr カテゴリー Ventilation Hood

Zephyr ZVE-E42Sのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ZVE-E42Sの取扱説明書
- Zephyrの製品カード
- パンフレット
- またはZephyr ZVE-E42Sの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Zephyr ZVE-E42Sの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Zephyr ZVE-E42Sの取り付け説明書、サービスマニュアル、簡易説明書、またはZephyr ZVE-E42Sのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Zephyr ZVE-E42Sの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Zephyr ZVE-E42Sデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがZephyr ZVE-E42Sを使用するのを助ける技術的文書のことです。説明書は通常、全てのZephyr ZVE-E42Sユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Zephyrの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Zephyr ZVE-E42Sの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははZephyr ZVE-E42Sの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Zephyr ZVE-E42Sに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Zephyr ZVE-E42Sデバイスの基本機能を使うにあたってのヒント。 Zephyr ZVE-E42Sのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Zephyr ZVE-E42Sに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるZephyr ZVE-E42Sのメーカー/サービスへの連絡先に関する情報。

Zephyr ZVE-E42Sについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもZephyr ZVE-E42Sの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがZephyr ZVE-E42Sで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)