Pelco C1501Mの取扱説明書

25ページ 2.42 mb
ダウンロード

ページに移動 of 25

Summary
  • Pelco C1501M - page 1

    ® Pelco World Headquarters • 3500 Pelco Way, Clovis, California 93612-5699 USA • www.pelco.com USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150 International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120 ADDENDUM Addendum No.: C1577M-A Date: August 4, 2004 Manuals Affected: CM9760 Series Manuals – C538M-A, C539M-A, C540M-B, C541M-C, ...

  • Pelco C1501M - page 2

    CM9760-REL System 9760 ® Relay Interface Unit Installation/ Operation Manual C538M-A (3/04) ® Pelco W orld Headquar ters • 3500 P elco W a y , Clovis, CA 93612-5699 USA • www .pelco.com USA & Canada: T el: 800/289-9100 • F ax: 800/289-9150 International: T el: 1-559/292-1981 • F ax: 1-559/348-1120 ...

  • Pelco C1501M - page 3

    2 Pelco Manual C538M-A (3/04) CONTENTS Section Page 1.0 GENERAL ................................................................................................... 3 1.1 IMPOR T ANT SAFEGU ARDS AND W ARNINGS ................................ 3 2.0 DESCRIPTION ........................................................................................... ...

  • Pelco C1501M - page 4

    Pelco Manual C538M-A (3/04) 3 Please thoroughly familiarize yourself with the information in this manual prior to installation and operation. 1.0 GENERAL 1.1 IMPORT ANT SAFEGUARDS AND W ARNINGS Prior to installation and use of this product, the following W ARNINGS should be obser v ed. 1. Installation and servicing should only be done by qualified ...

  • Pelco C1501M - page 5

    4 Pelco Manual C538M-A (3/04) 2.0 DESCRIPTION The CM9760-REL Rela y Interface Unit is an optional accessory of the System 9760 ® . The relay interf ace unit provides dry contact switching for direct or automatic con- trol of peripheral equipment. The unit connects to any RS-422 COMM port on the rear of the CM9760-CC1. Some of the more impor tant f ...

  • Pelco C1501M - page 6

    Pelco Manual C538M-A (3/04) 5 3.0 PRE-INST ALLA TION INFORMA TION 3.1 FRONT VIEW AND DIP SWITCH ACCESS Figure 1 illustrates a front vie w of the unit with its front panel removed. P ower (green) and Data (red) LEDs occupy opposite ends of the unit’ s front panel. As illustrated, the remov al of the five flat-head Phillips screws that hold the fro ...

  • Pelco C1501M - page 7

    6 Pelco Manual C538M-A (3/04) 3.2 REAR VIEW The rear of the unit is illustrated in Figure 2. F rom left to r ight are the f ollowing: 1. F our b locks consisting of 16 contact pairs, each with mating plugs f or the at- tachment of peripheral equipment. (Only the bloc k for the first 16 contact pairs is shown with mating plugs.) 2. RS-422 input/outp ...

  • Pelco C1501M - page 8

    Pelco Manual C538M-A (3/04) 7 3.2.1 REL Contact Pair Connections Physically , each rela y bloc k consists of 16 rela y contacts and two mating plugs. Since a relay contact requires tw o terminal positions, each plug provides 8 contacts via 16 screw terminals. To deter mine the screw terminal pin numbers f or a par ticular contact, refer to Figure 3 ...

  • Pelco C1501M - page 9

    8 Pelco Manual C538M-A (3/04) 3.2.2 External Relay Wiring Considerations Components of external rela y wiring are illustrated in Figure 4. 3.2.3 Communication Connectors Communication to and from the unit is provided through two RJ-45 ports on the rear of the CM9760-REL. The por ts are ph ysically ref erenced as IN and OUT por ts. The RJ-45 IN conn ...

  • Pelco C1501M - page 10

    Pelco Manual C538M-A (3/04) 9 3.2.3.2 RJ-45 Data Cables Because both RJ-45 connectors hav e the same wir ing pin-outs , they require the same “flipped” cable . In other words , the IN connector requires a “flipped” cable f or connecting the first unit to the CC1, and the OUT connector requires a “flipped” cable f or cascading other unit ...

  • Pelco C1501M - page 11

    10 Pelco Manual C538M-A (3/04) 3.2.4 Power Connections The CM9760-REL utilizes an auto-ranging internal transf ormer circuit that allows input power to range from 100-240 V A C , 50/60Hz. Associated with the input po wer is the power ON/OFF s witch and the input power fuse. The fuse is easily changed as illustrated in Figure 7. Figure 7. Pow er Inp ...

  • Pelco C1501M - page 12

    Pelco Manual C538M-A (3/04) 11 3.3 SETUP 3.3.1 Preliminary Discussion FRAME ADDRESSES The IRC, VCRC , and the CM9760-REL Rela y Interface Unit, all use software GPIs to activate control of e xter nal de vices. The number of GPIs required by each hardw are device v aries. The number of GPIs (General Purpose Interfaces) required by the REL is eight. ...

  • Pelco C1501M - page 13

    12 Pelco Manual C538M-A (3/04) When setting frame addresses on the front panel s witches for a group of daisy- chained REL units, k eep in mind a few working rules: WORKING RULES 1. Star t with frame address 0, which is associated with ph ysical GPI 1, and w ork sequentially forw ard until all relay interf ace units are accounted for . Insure that ...

  • Pelco C1501M - page 14

    Pelco Manual C538M-A (3/04) 13 3.3.2 DIP Switch Settings DIP switch settings are illustr ated and discussed in Figure 10. Figure 10. DIP Switch Functions ...

  • Pelco C1501M - page 15

    14 Pelco Manual C538M-A (3/04) Ta b le A. Fr ame Address, GPI Range Association (Continued on ne xt page) Daisy-Chained Frame Sub-Frame Combined Associated GPI Range Relay Units Addresses Addresses Frame/Sub-Frame Eight Required GPI #’ s Associated Running T otal SW2 SW3 Addresses with a Frame/Sub-Frame Address 12 3456 1 2 F A/SF A 1234567 8 10 0 ...

  • Pelco C1501M - page 16

    Pelco Manual C538M-A (3/04) 15 Ta b le A. Fr ame Address, GPI Range Association (Contin ued) 45 11 0100 0 0 1 1 0 353 354 355 356 357 358 359 360 46 11 0100 1 0 1 1 1 361 362 363 364 365 366 367 368 47 11 0100 0 1 1 1 2 369 370 371 372 373 374 375 376 48 11 0100 1 1 1 1 3 377 378 379 380 381 382 383 384 49 00 1100 0 0 1 2 0 385 386 387 388 389 390 ...

  • Pelco C1501M - page 17

    16 Pelco Manual C538M-A (3/04) Figure 11. Configur ing the GPI Define File f or REL Operation Figure 12. Configur ing the COMMS File f or REL Operation 3.3.3 Software Considerations Access to the operation of specific de vices connected to REL units using keyboards commands or macro operations depends on the GPI and the specific GPI ranges each REL ...

  • Pelco C1501M - page 18

    Pelco Manual C538M-A (3/04) 17 4.0 INST ALLA TION Physical installation of the REL unit is relativ ely simple, although v arious configura- tions are possible . 4.1 DIRECT RACK-MOUNT HOOK-UP The REL unit mounts in a standard 19-inch rack and occupies only one R U (1.75" or 4.45 cm) of rac k space (ref er to Figure 13). 4.2 REMOTE OPERA TION Th ...

  • Pelco C1501M - page 19

    18 Pelco Manual C538M-A (3/04) 4.3 DAISY -CHAINING Daisy-chaining occurs when more than 64 relays are required. More impor tantly , each unit must be configured to hav e a unique address , ref erred to as a F rame Address. F r ame addressing with respect to REL units was discussed in Section 3.3.1. What follows is a discussion about the ph ysical h ...

  • Pelco C1501M - page 20

    Pelco Manual C538M-A (3/04) 19 5.0 OPERA TION 5.1 OPERA TIONAL OVERVIEW The basic function of the REL unit is to allow the user/operator to control various peripheral equipment via relay contacts . Each REL unit processes and ex ecutes only commands with addresses that match that of the RELs (frame address). When an REL receives a command with an i ...

  • Pelco C1501M - page 21

    20 Pelco Manual C538M-A (3/04) Figure 15. Ph ysical Representation of Figure 16 REL UNIT 1 REL UNIT 2 REL UNIT 3 REL UNIT 4 REL UNIT 5 PERIPHERAL DEVICES PERIPHERAL DEVICES PERIPHERAL DEVICES PERIPHERAL DEVICES GPI RANGE FOR REL UNIT 5 PERIPHERAL EQUIPMENT ASSOCIA TED AU X ASSOCIA TED A UX ASSOCIA TED A UX ASSOCIA TED A UX ASSOCIA TED A UX ASSOCIA ...

  • Pelco C1501M - page 22

    Pelco Manual C538M-A (3/04) 21 Method II – The CM9760-GPI/AUX Calculator If we re visit the EXAMPLE just discussed and illustrated in Figures 15, we can immediately find the inf ormation needed by direct read-off from the information bo x es on the front of the calculator . Mov e the calculator wheel until the number “five” appears in the Rel ...

  • Pelco C1501M - page 23

    22 Pelco Manual C538M-A (3/04) Figure 16. Controlling REL Output Contacts From the CM9760-KBD Once the system is running and a keyboard is on-line , direct control of an REL is as f ollo ws (refer to Figure 16): 1. F rom the Default menu, use the k eyboard keypad to enter the GPI n umber that contains the relay output y ou wish to activ ate (data o ...

  • Pelco C1501M - page 24

    Pelco Manual C538M-A (3/04) 23 6.0 SPECIFICA TIONS ELECTRICAL REL UNIT RELAY CONTACTS** Parameters: Maximum Switching Capacity 60 Watts Maximum Operating Voltage 125V AC/DC Maximum Current 2 Amps Contact Resistance 75 m ohms Rated Load Parameters: .5A @ 125 VAC 2A @ 30 VDC REL UNIT Input Voltage: Auto-ranging 100-240 VAC 50/60 Hz Power: Consumption ...

  • Pelco C1501M - page 25

    24 Pelco Manual C538M-A (3/04) 7.0 W ARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved de- fective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3 ...

メーカー Pelco カテゴリー Security Camera

Pelco C1501Mのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- C1501Mの取扱説明書
- Pelcoの製品カード
- パンフレット
- またはPelco C1501Mの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Pelco C1501Mの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Pelco C1501Mの取り付け説明書、サービスマニュアル、簡易説明書、またはPelco C1501Mのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Pelco C1501Mの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Pelco C1501Mデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPelco C1501Mを使用するのを助ける技術的文書のことです。説明書は通常、全てのPelco C1501Mユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Pelcoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Pelco C1501Mの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPelco C1501Mの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Pelco C1501Mに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Pelco C1501Mデバイスの基本機能を使うにあたってのヒント。 Pelco C1501Mのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Pelco C1501Mに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPelco C1501Mのメーカー/サービスへの連絡先に関する情報。

Pelco C1501Mについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPelco C1501Mの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPelco C1501Mで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)