Mitsubishi Electronics MXZ-4A80VAの取扱説明書

12ページ 0.55 mb
ダウンロード

ページに移動 of 12

Summary
  • Mitsubishi Electronics MXZ-4A80VA - page 1

    Refer to the installation manual of each indoor unit for indoor unit installation. INST ALLA TION MANUAL FOR INST ALLER CONTENTS 1. THE FOLLOWING SHOULD AL W A YS BE OBSER VED FOR SAFETY ........................................................................................... 2 2. INST ALLA TION DIAGRAM & ACCESSORIES ......................... ...

  • Mitsubishi Electronics MXZ-4A80VA - page 2

    2 K H F I J E C D 2 . INST ALLA TION DIAGRAM & ACCESSORIES 1. THE FOLLOWING SHOULD AL W A YS BE OBSER VED FOR SAFETY • Be sure to read “THE FOLLOWING SHOULD ALW A YS BE OBSERVED FOR SAFETY” before install- ing the air conditioner . • Be sure to observe the cautions specified here as they include important items related to safety . • T ...

  • Mitsubishi Electronics MXZ-4A80VA - page 3

    3 Parts to be locally procured A Power supply cord 1 (3-core 2.5 mm 2 ) B Indoor/outdoor unit connecting wire 1 (4-core 1.0 mm 2 /1.5 mm 2 ) C Extension pipe According to “Selecting pipe size” 1 D Wall hole cover 1 E Piping tape 1 F Extension drain hose (or soft vinyl chloride hose of 1 15 mm in internal dia. or hard vinyl chloride pipe VP16) G ...

  • Mitsubishi Electronics MXZ-4A80VA - page 4

    4 4. OUTDOOR UNIT INST ALLA TION 4-1 INST ALLING THE UNIT • Be sure to fix the unit ’ s legs with bolts when installing it. • Be sure to install the unit firmly to ensure that it does not fall by an earthquake or a gust. • Refer to the figure in the right for concrete foundation. Note: The length of anchor bolts should be within 25 mm from ...

  • Mitsubishi Electronics MXZ-4A80VA - page 5

    5 Connect to the supply terminals and leave a contact separation of at least 3 mm at each pole to disconnect the source power pole. (When the power switch is shut of f, it must disconnect all poles.) <Front View> <Right Side View> 35 mm 15 mm Indoor/Outdoor unit connecting wire B Cable clamp Power supply cord A 4-4 INDOOR/OUTDOOR WIRE C ...

  • Mitsubishi Electronics MXZ-4A80VA - page 6

    6 Copper pipe Good No good Tilted Uneven Burred Burr Copper pipe Spare reamer Pipe cutter Flare nut Copper pipe 5-2 FLARING WORK • Main cause of gas leakage is defect in flaring work. Perform flaring work correctly in the following procedure. 1. Pipe cutting • Cut the copper pipe correctly with pipe cutter . 2. Burrs removal • Completely remo ...

  • Mitsubishi Electronics MXZ-4A80VA - page 7

    7 A Die Copper pipe Flare nut Die Copper pipe Smooth all around Even length all around Inside is shining without any scratches Y ork 4. Flaring work • Perform flaring work using flaring tool as shown in the right. A (mm) Outside diameter Flare tool for R410A Conventional flare tool clutch type Clutch type Wing nut type ø 6.35 mm 0 to 0.5 1.0 to ...

  • Mitsubishi Electronics MXZ-4A80VA - page 8

    8 W ARNING: When installing or moving the unit, do not mix anything other than specified refrigerant (R410A) into the refrigerating cycle. If air is mixed, it may cause the refrigerating cycle to get abnormally high temperature, causing a risk of burst. Tightening torque N · m kgf · cm Cap for service port 13.7 to 17.7 140 to 180 Cap for stop val ...

  • Mitsubishi Electronics MXZ-4A80VA - page 9

    9 A B C D 5-9 GAS CHARGE Perform gas charge to unit. 1 Connect gas cylinder to the service port of stop valve. 2 Perform air purge of the pipe (or hose) coming from refrigerant gas cylinder . 3 Replenish specified amount of the refrigerant, while operating the air conditioner for cooling. Note: In case of adding refrigerant, comply with the quantit ...

  • Mitsubishi Electronics MXZ-4A80VA - page 10

    ...

  • Mitsubishi Electronics MXZ-4A80VA - page 11

    ...

  • Mitsubishi Electronics MXZ-4A80VA - page 12

    HEAD OFFICE: T OKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN SG79Y674H01 ...

メーカー Mitsubishi Electronics カテゴリー Air Conditioner

Mitsubishi Electronics MXZ-4A80VAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- MXZ-4A80VAの取扱説明書
- Mitsubishi Electronicsの製品カード
- パンフレット
- またはMitsubishi Electronics MXZ-4A80VAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mitsubishi Electronics MXZ-4A80VAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mitsubishi Electronics MXZ-4A80VAの取り付け説明書、サービスマニュアル、簡易説明書、またはMitsubishi Electronics MXZ-4A80VAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mitsubishi Electronics MXZ-4A80VAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Mitsubishi Electronics MXZ-4A80VAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMitsubishi Electronics MXZ-4A80VAを使用するのを助ける技術的文書のことです。説明書は通常、全てのMitsubishi Electronics MXZ-4A80VAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mitsubishi Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mitsubishi Electronics MXZ-4A80VAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMitsubishi Electronics MXZ-4A80VAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mitsubishi Electronics MXZ-4A80VAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mitsubishi Electronics MXZ-4A80VAデバイスの基本機能を使うにあたってのヒント。 Mitsubishi Electronics MXZ-4A80VAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mitsubishi Electronics MXZ-4A80VAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMitsubishi Electronics MXZ-4A80VAのメーカー/サービスへの連絡先に関する情報。

Mitsubishi Electronics MXZ-4A80VAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMitsubishi Electronics MXZ-4A80VAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMitsubishi Electronics MXZ-4A80VAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)