    AD1200EXP MCS Hard-wire Controller Expander Installation Instructions The manual describes the installation procedures for the American Dynamics AD1200EXP MCS Hard-wire Controller Expander. Before installation, become familiar with all of the special features and warnings associated with this equipment. Store this manual in a safe, convenient locat ...

  • American Dynamics AD1200EXP - page 2

    This software/firmware is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software is furnished to the purchaser under a license for use on a single system. NOTE: Information furnished by SENSORMATIC is believed to be ...

  • American Dynamics AD1200EXP - page 3

    The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture. AMERICAN DYNAMICS CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMO ...

  • American Dynamics AD1200EXP - page 4

    T able of Contents DESCRIPTION............................................................................................................................ 1 FEATURES ................................................................................................................................. 1 MAINTENANCE ........................................ ...

  • American Dynamics AD1200EXP - page 5

    1 AD1200EXP DESCRIPTION DESCRIPTION The AD1200EXP Hardwired Controller Expander increases the number of pan/tilt sites controlled from a single AD1200A Hard-wired Controller from one to four. Cascading multiple AD1200EXP units increases the number of pan/tilt sites available from four to a maximum of sixteen. The AD1200EXP features spring loaded pu ...

  • American Dynamics AD1200EXP - page 6

    2 INSTALLATION Front Panel Description Site Selection Pushbuttons: Four spring-loaded pushbuttons select the individual pan/tilt unit the operator wishes to control (see Figure 2). Internal LED illumination indicates current site selected. Rear Panel Description Options DIP Switch A 4-position DIP switch identifies individual AD1200EXP units when c ...

  • American Dynamics AD1200EXP - page 7

    3 AD1200EXP INSTALLATION Figure 3 - AD1200EXP Rear Panel Layout 14- P in C onne c ter s ( 4) 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 1 2 3 Gr ound C onne c ti on 4 14- P in R a m p C onne c tor Opt i o ns DIP Switc h 0 1 2 3 G 5- P in C onne c ter s ( 2) OF F ...

  • American Dynamics AD1200EXP - page 8

    4 Mounting The AD1200EXP is suitable for desktop operation or mounting in a standard EIA rack. The American Dynamic's AD2117/21 Rack Mount Hardware Kit is recommended for mounting one or two AD1200EXPs in a standard EIA rack. Power The AD1200EXP is configured for use with 24VAC power. A single AD1200EXP unit receives its power directly from th ...

  • American Dynamics AD1200EXP - page 9

    AD1200EXP INSTALLATION 5 A D1200EX P 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 AUT O SC AN 120V 60Hz LEN S ADJ UST AUX P/ T A/ P LEN S U D R L 1 2 H R C I F Z CP 1 2 3 4 OFF A D1200A C ontr olle r C HAS S IS GR OUND AUX P/T A/P LENS U D R L 1 2 H R C I F Z CP 14- P in C onne c tor ZOOM FO CU S IR ...

  • American Dynamics AD1200EXP - page 10

    Cascading Multiple AD1200EXP Units Multiple AD1200EXP units are used to increase the number of pan/tilt sites available to a single AD1200A Hard-wired Controller from four to a maximum of sixteen. Each AD1200EXP unit is provided with one 5-pin strap harness for cascading purposes. 1. Beginning with the LAST AD1200EXP unit, connect a suitable ground ...

  • American Dynamics AD1200EXP - page 11

    7 AD1200EXP INSTALLATION 1 2 3 4 0 1 2 3 G A D1200EX P 1 2 3 4 0 1 2 3 G 0 1 2 3 G 1 2 3 4 C ha ssis G r ound C onne c ti on ( 1 8 AWG S o l i d Wi re) to AD1200A H a rd- w i r e Cont r oll e r C ha ssis G r ound Te r m i na l S t rap Harnes s 1 2 3 4 0 1 2 3 G S t rap Harnes s OFF S t rap Harnes s 5- P in C onne c tor w/ S t r ap Harn es s A t t a ...

  • American Dynamics AD1200EXP - page 12

    8 Powering Multiple AD1200EXP Units Connecting multiple (maximum of 4) AD1200EXP units to one AD1200A Controller requires the use of an external 120VAC to 24VAC step-down transformer. NOTE: Connecting multiple AD1200EXPs for European operation requires the use of a 230VAC to 24VAC step-down transformer. The first AD1200EXP draws 24VAC power directl ...

  • American Dynamics AD1200EXP - page 13

    9 AD1200EXP INSTALLATION AUT O SC A N 120V 60Hz LEN S ADJ US T AUX P/T A/P LEN S U D R L 1 2 H R C I F Z CP 1 2 3 4 OF F A D1200A Ha r d- w ir e C ontr olle r A D1200EX P Un it #1 24VAC CO MMO N 24VAC P OWER A D1200EX P Un it #2 A D1200EX P Un it #3 A D1200EX P Un it 4 U D R L 1 2 R C I F Z N C N C U D R L 1 2 R C I F Z N C N C 0 1 2 3 G 1 2 3 4 OF ...

  • American Dynamics AD1200EXP - page 14

    10 Connecting Multiple AD1200EXP Units A maximum of four AD1200EXP units may be connected to one AD1200A Hard-wired Controller. All AD1200EXP units connect to the AD1200A Hard-wired Controller via a single 14-pin connector (provided with the AD1200 Hard-wire Controller). Each of the terminals on the 14-pin connector is large enough to accept four l ...

  • American Dynamics AD1200EXP - page 15

    11 Figure 8 - Multiple AD1200EXP Unit -to- AD1200A Hard-wired Controller Connection AD1200EXP INSTALLATION U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C U D R L 1 2 R C I F Z N C N C N C 0 1 ...

  • American Dynamics AD1200EXP - page 16

    12 AD1200EXP to Pan/Tilt Site Connection The AD1200EXP provides connection ports to four pan/tilt units via 14-pin connectors. NOTE: The AD1200EXP does not provide power to either the pan/tilt or the camera. 1. Using Table 4 as reference, connect each lead from the pan/tilt unit to the appropriate terminal of the 14-pin connector (see Figure 9). 2. ...

  • American Dynamics AD1200EXP - page 17

    13 AD1200EXP INSTALLATION 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C 0 1 2 3 G 12 3 4 A D1200EX P U D R L 1 2 R C I F Z N C N C N C A D1240 P a n/ T ilt U D R L 1 2 R C I F Z N C N C N C 1 ZOOM FOCUS IR IS LENS C O MMO N UP DOW N R I GHT LEF T U D R L 1 2 R C I F Z N C N C N C 3 ZOOM FO CU S IR IS COMMO N UP DOWN R IGHT LEF T A D1240 P a n/ T ilt AU ...

  • American Dynamics AD1200EXP - page 18

    14 CCTV Switcher System Connection AD1200EXP units provide a 5-pin connector for use with CCTV switcher systems. Each AD1200EXP unit is provided with one 5-pin strap harness and two 5-pin mating connectors. AD1200EXP to AD1412 Series Switcher Connection The AD1200EXP is designed for complete operating compatibility with the AD1412 and AD1412L Seque ...

  • American Dynamics AD1200EXP - page 19

    15 AD1200EXP INSTALLATION 120V 60H z 120V 60H z J1 J2 J2 J1 AD 1416L w / Loopi ng Re a r P a ne l M ONIT OR A B CA MERA J3 M ONIT OR AB CA MERA 12 34 56 7 89 1 0 1 1 1 2 1 4 1 5 1 6 13 J3 AD 1416 w / T e r m i na te d R e a r P a ne l 12 34 56 78 9 1 0 1 1 1 2 1 4 1 5 1 6 13 A D1200EX P 1 2 3 4 U D R L 1 2 R C I F Z N C N C N C 1 2 3 4 0 1 2 3 G U ...

  • American Dynamics AD1200EXP - page 20

    16 SETUP 4-Position DIP Switch A 4-position DIP switch configures the AD1200EXP for the number of operational cameras and for use within a CCTV switching system. The 4-position DIP switch is mounted on the AD1200EXP rear panel (see Figure 12). Using Table 8 as reference, read the following descriptions of each of the four DIP switches. DIP Switch # ...

  • American Dynamics AD1200EXP - page 21

    17 AD1200EXP OPERATION OPERATION Single AD1200EXP Unit Operation A single AD1200EXP unit provides operational control to a maximum of four pan/tilt sites. 1. Press the appropriate pushbutton (1-4) to select the desired pan/tilt site (see Figure 13). 2. Select the desired pan/tilt function on the AD1200A Hard- wired Controller. Multiple AD1200EXP Un ...

  • American Dynamics AD1200EXP - page 22

    ...

  • American Dynamics AD1200EXP - page 23

    APPENDIX ...

  • American Dynamics AD1200EXP - page 24

    ...

  • American Dynamics AD1200EXP - page 25

    A1 AD1200EXP INDEX Cable Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Auxiliary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Cascading Multiple AD1200EXP Units . . . . . . . . . . . . . . 6 Connector, 14-Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Connector, Pin Fun ...

  • American Dynamics AD1200EXP - page 26

    A2 AD1200EXP DIMENSIONS 1. 74" 44. 5m m 10. 3" 261. 6m m 8. 5" 216m m 12 34 MCS PTZ CONTROLLER EXPANDER ...

  • American Dynamics AD1200EXP - page 27

    ...

  • American Dynamics AD1200EXP - page 28

    An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River, New York, 10965 (914) 624-7600 Technical Support Center: 800-442-2225 FAX: (914) 624-7685 8000-0929-01 OP1200EXPC October, 1997 Printed in USA SPECIFICATIONS MODELS AD1200EXP Hard-wire Controller Expander (North America) ELECTRICAL ...

メーカー American Dynamics カテゴリー Hard-wire Controller

American Dynamics AD1200EXPのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- AD1200EXPの取扱説明書
- American Dynamicsの製品カード
- パンフレット
- またはAmerican Dynamics AD1200EXPの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Dynamics AD1200EXPの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Dynamics AD1200EXPの取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Dynamics AD1200EXPのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Dynamics AD1200EXPの製品を使用するにあたって最も人気のある説明書を閲覧できます。

American Dynamics AD1200EXPデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Dynamics AD1200EXPを使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Dynamics AD1200EXPユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Dynamicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Dynamics AD1200EXPの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Dynamics AD1200EXPの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Dynamics AD1200EXPに関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Dynamics AD1200EXPデバイスの基本機能を使うにあたってのヒント。 American Dynamics AD1200EXPのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Dynamics AD1200EXPに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Dynamics AD1200EXPのメーカー/サービスへの連絡先に関する情報。

American Dynamics AD1200EXPについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Dynamics AD1200EXPの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Dynamics AD1200EXPで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)