Bogen SI35Aの取扱説明書

24ページ 1.68 mb
ダウンロード

ページに移動 of 24

Summary
  • Bogen SI35A - page 1

    Power Intercom Systems Models PI35A & SI35A Installation & Operation Guide : http://www. guardianalarms . net ...

  • Bogen SI35A - page 2

    © 1997 Bogen Communications, Inc. 50 Spring St., Ramsey , NJ 07446 All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Bogen Communications, Inc. Notice: The information contained in this document is subject to change without notice and should not ...

  • Bogen SI35A - page 3

    Contents Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Wiring & Grounding Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Auxiliary Power Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Maintenance & Se ...

  • Bogen SI35A - page 4

    Unpacking Y our Bogen equipment was carefully checked before leaving the factory; inspect the shipping container and unit closely for improper handling. If the unit has been damaged, make an immediate claim to the distributor from whom it was purchased. If the unit was shipped directly to you, save all shipping materials and notify the carrier imme ...

  • Bogen SI35A - page 5

    Introduction Description Bogen Models PI35A and SI35A are 25-station intercom systems (SI35A is expandable to 75 stations). They can provide facilities with two-way communication, emergency paging, time tones and background music or other audio program material to speaker-equipped locations. Both systems consist of a master control panel (Bogen mod ...

  • Bogen SI35A - page 6

    MCP35A Control Panel Front Panel 1. CONSOLE MIC - Used as microphone 1 or in conjunction with the emergency page or press-to-talk/release- to-listen (intercom) push-buttons. This mic is always used for two-way intercom calls, using the green button, and emergency paging using the red button. No external mic can replace the console mic for these fun ...

  • Bogen SI35A - page 7

    MCP35A Control Panel Rear V iew 1. MIC 1 — Connections for an external mic (MIC 1). When the PROGRAM DISTRIBUTION button MIC 1 is pressed, the microphone connected here becomes active. As shipped from the factory , a link is installed between the HI and CONS MIC terminals. This makes the CONSOLE MIC act as MIC 1. When the link is removed, an exte ...

  • Bogen SI35A - page 8

    SBA225 Speaker Selector Panel Front V iew 1. Room selector switch — Position of the room switch controls the type of audio program material delivered to the room speaker . 2. Call annunciators — Lights to indicate a room has placed an intercom request from a call switch 3. Program busses — A room speaker can be turned off or connected to one ...

  • Bogen SI35A - page 9

    Basic System Operation Communicating With a Selected Speaker Use the following steps to talk and listen to a room that has its switch set to the “C” (down) position. 1. Place the switch of the room that you wish to talk and listen to in the “C” (down) position. 2. Make sure the PROGRAM DISTRIBUTION button MIC 1 is in the out position; if no ...

  • Bogen SI35A - page 10

    Basic System Hook-Up 4-Wire Speaker Connections to the SBA225 4-wire speaker connections (3-conductor + shield) is recommended for all new installations. The figure below shows the connection to the back of the SBA225 when using a 4-wire system. Note: Y ou must use Bogen connectors for this connection. There are different connectors available for d ...

  • Bogen SI35A - page 11

    Call-In Switches T wo call-in switches, CA10A and CA1 1A, are recommended for use with the SI and PI. The CA10A is a momen- tary push switch that has circuitry to light the annunciator light on the SBA225 room selector panel. The CA1 1A has the same capability as the CA10A and includes a privacy lock-out position that inhibits the MCP35A control pa ...

  • Bogen SI35A - page 12

    Speakers and Speaker Wiring The MCP35A control panel of the SI and PI products is designed to use 25-volt distributed speakers. These speakers have line-matching transformers with various power level taps. 8-ohm speakers or speakers without line-matching transformers cannot be used with the SI and PI products. Distributed speakers can be tapped at ...

  • Bogen SI35A - page 13

    Advanced Hook-Ups External Emergency Mic It is possible to use a microphone (Model MBS1000) with a contact closure to make an emergency announce- ment. The TELCO terminal on the back of the MCP35A control panel can be used to remotely trigger an emer- gency page on the system. Whenever the TELCO terminal is shorted to the GND terminal the MIC 2 inp ...

  • Bogen SI35A - page 14

    The Bogen model T AMB telephone interface module can be used to make a remote page through the telephone system. A Bogen TP-AP Series Interphone can be used to make a remote page. The figure below shows the connec- tion. 14 Note: Jumper J3 on the MCP35A printed circuit board must be set to the TELCO position. See the Special Adjustments sec- tion f ...

  • Bogen SI35A - page 15

    External Booster Amp An external booster amplifier (Bogen Model BP A60) can be connected when the application requires more than 35 watts. Using an external amplifier disconnects the internal 35W amp of the MCP35A. T o install, connect a RCA cable from the MCP35A LINE OUT jack to the Hi-Z input jack on the rear panel of the BP A60 amplifier . Conne ...

  • Bogen SI35A - page 16

    TWK351 Wire Converter The model TWK351 is an adapter used in instances where there is existing 3-wire (2-conductor + shield) room wiring. The TWK351 cannot be used with the SCR25A module. If 3-wire operation using the TWK351 wire converter is desired, CA10A call switches must be used (CA1 1A Call-In switches will not work in this application). T o ...

  • Bogen SI35A - page 17

    SCR25A Call-In Module The SCR25A module can be added to allow the annunciator indicators to light from a simple SPST call-in switch (Bogen model CA17). All call-in switches must go back to the SI or PI on separate lines. It will not allow annun- ciator illumination from parallel connected call-in switches described in the V oice call-in section. Th ...

  • Bogen SI35A - page 18

    SI35A Model Option Enhancements The SI35A has provisions to add up to 2 additional SBA225 switchbanks. Simply remove the blank panels and replace with a switchbank. Make connections as shown in the diagram below . An auxiliary music source, such as the Bogen CR100A Radio/Cassette Player or TP30D T uner can also be added to the SI35A. Install the co ...

  • Bogen SI35A - page 19

    Special Adjustments Gain Adjustments Screwdriver-adjustable INPUT GAIN controls are located on the rear panel for MIC 1, MIC 2, AUX, TEL P AGE, T ALK and LISTEN. Set the controls so that signal clipping cannot occur . Proceed as follows: 1. Apply input(s) to the desired channel(s). 2. Set the corresponding front panel control(s) to maximum. 3. Adju ...

  • Bogen SI35A - page 20

    Internal Jumper Selections Internal jumpers are provided for phantom power (Mic1/Mic2), T elco Page/Mic 2 input selection, monitor speaker muting, and privacy tone defeat. W arning High voltages are present within the MCP35A. The unit should not be operated without covers in place. T o change jumpers, unplug the MCP35A and remove it from the enclos ...

  • Bogen SI35A - page 21

    T roubleshooting Guide MCP35A T roubleshooting Procedure If a problem exists on the MCP35A, certain steps should be taken to find the problem. This test relates to the Program Amplifier (All-Call or Emergency). The first indication of a problem will appear on the three level indi- cators at the front of the unit. They are green, yellow , and red. I ...

  • Bogen SI35A - page 22

    System Specifications Rated Output: Program — 35W RMS Intercom — 20W RMS Frequency Response: Program — +1,-3dB from 80Hz to 15kHz Intercom — Shaped for maximum intelligibility Distortion: Less than 1% at rated power and bandwidth Inputs: T wo Lo-Z balanced MIC inputs; Hi-Z unbalanced AUX input; T elco Page; 25V Booster input Output: 25V Bal ...

  • Bogen SI35A - page 23

    ...

  • Bogen SI35A - page 24

    50 Spring Street, Ramsey , NJ 07446, U.S.A. T el: 201-934-8500 Fax: 201-934-9832 web: www .bogen.com ...

メーカー Bogen カテゴリー Intercom System

Bogen SI35Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SI35Aの取扱説明書
- Bogenの製品カード
- パンフレット
- またはBogen SI35Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bogen SI35Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bogen SI35Aの取り付け説明書、サービスマニュアル、簡易説明書、またはBogen SI35Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bogen SI35Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bogen SI35Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBogen SI35Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのBogen SI35Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bogenの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bogen SI35Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBogen SI35Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bogen SI35Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bogen SI35Aデバイスの基本機能を使うにあたってのヒント。 Bogen SI35Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bogen SI35Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBogen SI35Aのメーカー/サービスへの連絡先に関する情報。

Bogen SI35Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBogen SI35Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBogen SI35Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)