GE 255 Valve / 400 Seriesの取扱説明書

32ページ 1.38 mb
ダウンロード

ページに移動 of 32

Summary
  • GE 255 Valve / 400 Series - page 1

    Autotrol ® Brand 255 V alve / 400 Series Controls W ater Conditioning Control System Home Owner Inst allation, Operation, and Maintenance Manual For sales or service questions please cont act your local dealer: Y our Local Dealer Is: 1018075 Rev I.fm Page 1 Tuesd ay, February 17, 2004 4:26 PM ...

  • GE 255 Valve / 400 Series - page 2

    2 T able of Content s Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 V alve Illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installa ti ...

  • GE 255 Valve / 400 Series - page 3

    3 Safety Information This water conditio ner ’s control valve conf orms to NSF/ANSI 44 for materials and structural integrity only . Generic systems were tested and certified by WQA as verified by the performan ce data sheet. • Please review this entire Installation and Operation manual before installing unit. • As with all plumbing project s ...

  • GE 255 Valve / 400 Series - page 4

    4 V alve Illustration Autotrol 255 V alve Control Module Figure 2 B Y P A S S B Y P A S S Optional i-lid Cov er T ank Adapter Module Figure 1 Air Check Brine Line Fitting Connectio n Probe Connection Slot T ank Thread 2-1/2-inch - 8 male Inlet Connection 3/4-inch or 1-inch NP T or BSPT Drain Connection 3/8-inch or 1/2-inch NP T or BSPT Outlet conne ...

  • GE 255 Valve / 400 Series - page 5

    5 Introduction The 255 series control incor porates five cycles during operation, Figure 3 and is responsible for directing the flo w of water during all phases of regeneration. The water conditioner consist s of a control valv e, mineral tank, re sin and a salt storage tank. During the service cycle, hardness contaminant s are removed from the wat ...

  • GE 255 Valve / 400 Series - page 6

    6 Figure 3 Inst allation All plumbing must conform to local codes. Inspect unit carefully for carrier sh ortage or shipping damage. Location Selection 1. The distance between the unit and a dr ain should be as short as possible. 2. If it is likely that supple menta ry water treating equipment will be required, make certain adeq uate additional spac ...

  • GE 255 Valve / 400 Series - page 7

    7 rated tempera ture and pressure safety r elief valve. Also, be cert ain that local codes are not violated. 5. Do not locate unit where it or it’ s co nnections (including the d rain and overflow lines) will ever be subjected to room temperat ures under 34 o F (1 o C) or ov er 120 o F (49 o C). 6. Do not install unit nea r acid or acid fumes. 7. ...

  • GE 255 Valve / 400 Series - page 8

    8 Drain Line Connection 1. Ideally located, the unit will be above and not more than 20 feet (6.1 m) from the drain. For such inst allations, use an appr opriate adapter fitting (not supplied), to connect 1/2-inch (1.3-cm) plastic tubing to the drain line connection of the control valve. 2. If the unit is located more than 20 feet (6.1 m) from drai ...

  • GE 255 Valve / 400 Series - page 9

    9 Overflow Line Connection In the absence of a safety overflow and in the event of a malfunction, the BRINE T AN K OVERFLOW will direct “o verflow” to the drain instead of spilling on the floor where it cou ld cause con siderable dama ge. This fitting should be on the side of the cabinet or brine t ank. T o connect overflow , locate hole on sid ...

  • GE 255 Valve / 400 Series - page 10

    10 Increasing the Length of the T ransformer Cord If it is necess ary to extend the length of the transf ormer cord, a n optional 15 -foot (4.6-m) ex tension is av ailable (see Fig ure 9). Figure 8 Figure 9 Disinfection of W ater Conditioners The materials of constructi on of the modern water co nditioner will not support bacterial growth, nor will ...

  • GE 255 Valve / 400 Series - page 11

    11 Sodium or Calcium Hypochlorite Application These materials ar e satisfactory for use with polystyrene re sins, synthetic gel zeolite, greensand an d bentonites. 5.25% Sodium Hypochlorite These solutions are availab le under trade names such as Clorox*. If stronger solutions are used, such as those sold for commercia l laundries, adjust the dosag ...

  • GE 255 Valve / 400 Series - page 12

    12 COUNTERCLOCKWISE only until arrow or knob point s to desired position. Rotation is made much easier if you grasp the camshaft with yo ur free hand and turn it at the same time. Then permit kno b to spring back out. 2. Insert screwdriver into slot in indicator knob (Figu re 1 1). Press in and rotate knob COUNTERCLOCKWISE until arrow points di rec ...

  • GE 255 Valve / 400 Series - page 13

    13 Control Valve Figure 10 - Control Valve 5. Put into operation. a. Open water supply valve slowly to full open posi tion. b. Carefully advance indicator knob COUNTERCLOCKWISE to center of F AST RINSE/REFILL position and hold there unt il air check (Figure 10) fills with water and water star ts to flow through brine line into b rine tank. Do not r ...

  • GE 255 Valve / 400 Series - page 14

    14 400 Series Control Settings 440i Control Figure 11 Programming 1. Set days of regeneration on skipper wheel (Figure 1 1). • Pull all skipper pi ns outward (away from control). • Rotate skipper wheel until day arrow points to curr ent day or number 1. • Depress skipper pin(s) at day( s ) for which regener ation is desired. 2. Set the time o ...

  • GE 255 Valve / 400 Series - page 15

    15 460i Control Figure 12 Programming Plug the wall-moun t transformer into a fu nc tioning electrical outlet that is not controlled by a switch. Plug the transfo rmer into the transformer plug recept acle on the control. Open the access door by pushing the raised tab on the door toward the lef t while pulling the tab out (Figure 12). Time of Day S ...

  • GE 255 Valve / 400 Series - page 16

    16 Hardness Setting Move the jumper to the set of pins next to the word HARDNESS (Figure 14). Press the bla ck TIME SET button until t he hardness of the incoming wate r supply is displayed. The hardness range is from 1 to 99 grains per gallon. T o change water hardness st ated in part s per million ( PPM) to grains per gallon (GPG) use th is formu ...

  • GE 255 Valve / 400 Series - page 17

    17 4. Depress the black TIME SET button. The numbers will roll fr om “0” to “15.” Release the switch at the de sired number of days for the calendar override. For example, releasing the switch at “10” would pr ogram a 10-day calendar override. 5. Disconnect powe r . 6. Place jumper back on TIME and reconnect power . 7. The calendar over ...

  • GE 255 Valve / 400 Series - page 18

    18 *This setting requires the use of “XS” (e xtra salt) cam and double s the amount of the setting. The amount of salt placed in the brine t ank has nothing to do with the amount of salt used during the regeneration cycle. Wa ter will di ssolve and absorb salt only until it becomes satura ted. A given amount of brine (salt-satura ted water) con ...

  • GE 255 Valve / 400 Series - page 19

    19 Preventive Maintenance Inspect and clean brine t ank and screen f ilter on end of brine pickup tube once a year or when sediment ap pears in the bottom of the brine tank. Clean injector scr een an d injector once a year : 1. Unplug the wall-mount transformer . 2. Shut off water supp ly or put bypass valve( s) into bypass positio n. 3. Relieve sy ...

  • GE 255 Valve / 400 Series - page 20

    20 Replacement Part s for Autotrol Brand 255 Control V alve Body 19 21 18 6 5 4 3 2 1 7 8 9 10 11 12 7 16 15 13 23 22 22 23 21 21 22 17 22 i n l e t o u t l e t d r a i n 20 14 T ank Adapter Module 1018075 Rev I.fm Page 20 Tu esday, February 17, 2004 4:26 PM ...

  • GE 255 Valve / 400 Series - page 21

    21 255 V alve & T ank Adapter Module Code Part No. Descripti on Qty . 1 1000232 V alve Assembly , w/o Flow Contro ls 1 2 Camshaft: 1 1031950 St andard, One-Piece 1033024 St andard, Segmented 1033025 Extra Sal t, Segmented 1033026 Long Rinse , Segmented 1032969 Water Saver , Segmente d 3 1030501 Camshaft Bearing 1 4 1031391 T imer Locking Pin 1 ...

  • GE 255 Valve / 400 Series - page 22

    22 * Not Shown **Flow control does not use Flow Control Ball (1030502). Kits: 21 1001404 O-Ring Gro up: T ank Adapter , 10101 17 (1), 1010407 (1), 101041 0 (4) 22 1040459 O-Ring Gro up: Piping Boss 1010431 (1), 101041 1 (2 ) 23 1041010 13/16 R ubber Insert (Optional) V alve Discs: * 1000250 S tandard 1018075 Rev I.fm Page 22 Tu esday, February 17, ...

  • GE 255 Valve / 400 Series - page 23

    23 Replacement Part s T O S E T T IM E O F D A Y P U LL K N O B A N D R O T A T E MA NUAL REG ENERA ION : P R E S S K N O B A N D T U R N CO U N T E R - CL O CKWIS E T O"S T A R T" Ð R E L E A S E 6P M 3P M 9A M 6A M 3A M N O O N M ID N I G H T B A CKWAS H S T A R T CO N D IT IO N E D WA T E R F A S T R IN S E / R E F IL L B R IN E / D A ...

  • GE 255 Valve / 400 Series - page 24

    24 255 Series Acce ssories Code Part No. Description Qty . 1 440i Assembly 1 2 460i Assembly 1 3 T ransformer 1 1000810 Japanese 100081 1 North American 1000812 Austral ian 1000813 British 1000814 Europea n * 1030234 T ransformer Extension Cord 15 foot (4.5 m) 1 1 Piping Boss Kit (i ncludes Hardware): 1 1040277 3/4-inch NPT , Brass 3/8-inch NPT Dra ...

  • GE 255 Valve / 400 Series - page 25

    25 * 1001606 3/4-inch Copper Tube Adapter Kit 1 * 1001670 1-inch Copper Tube Adapter Kit 1 * 1041210 1-1/4-inch Copper Tube Adapter Kit 1 * 1040547 90 degree Elbow Adapter Kit 1 * 1001608 22-mm Copper Tube Adapter Kit 1 * 1001613 3/4-inch CPVC Tube Adapter Kit 1 * 1001614 1-inch CPVC T ube Adapter Kit 1 * 1001615 25-mm CPVC T ube Adapter Kit 1 * 10 ...

  • GE 255 Valve / 400 Series - page 26

    26 T roubleshooting The technology upon which the Series 25 5 control is based is well est ablished and proven in service over many year s. Howe ver , shou ld a problem or quest ion arise regarding the operation of the system, the control can be very easily serviced. Th e control mo dule can be q uickly replaced or adjustments can be made at the in ...

  • GE 255 Valve / 400 Series - page 27

    27 4. Control will not draw brine. a. Low water pressure. b. Restricted drain li ne. c. Injec tor plugged ! d. Injector defecti ve ! e. V alve disc 2 and/or 3 not closed. f. Air check valve prematurely closed. a. Make correct setting according to instructions. b. Remove restriction. c. Clean inject or and screen. d. Replace injector and cap. (Conta ...

  • GE 255 Valve / 400 Series - page 28

    28 255/440i T roubleshooting Problem Possible Cause Solution 1. Control will not regenerate automatically . a. T ransformer or motor not connected. b. Defective timer mot or . c. Skipper pi ns not down on timer skipper wheel. d. Binding in g ear train of timer . a. Connect power . b. Replace motor . (Contact dealer .) c. Depress pins for days regen ...

  • GE 255 Valve / 400 Series - page 29

    29 255/460i T roubleshooting 7. Control backwashes or purges at excessively low or high rate. a. Incorre ct drain cont roller used. b. Foreign matter af fecting controller operati on. a. Replace with correct size controller . (Contact dealer .) b. Remove drain controll er and clean ball a nd seat. Problem Possible Cause Solution 1. Clock does not d ...

  • GE 255 Valve / 400 Series - page 30

    30 6. Control regenerates at wrong time of d ay . a. Power outages. b. Clock set in correctly . a. Reset cl ock to correct time of day . b. Reset cl ock to correct time of day . 7. T imer stalled in regenerati on cycle. a. Motor dead. b. Motor runs backward. c. No e lectric power at outlet. d. Broken gear . e. Defective switch. f. Air lea k in brin ...

  • GE 255 Valve / 400 Series - page 31

    31 10. Control will not regenerate automatically but will regene rate when button is pressed. a. If water flow display i s not operative, refer to Item 5. b. Defective ci rcuit board. c. Incorrect h ardness and capacity settings . a. Same as Item 5. b. Replace timer . (Contact dealer .) c. Set to correct values. See Programming section. 1 1. R un o ...

  • GE 255 Valve / 400 Series - page 32

    © Copyright 2004 GE Water Technologies Printed in t he USA P/N 10180 75 Rev. I For service or parts, please c ontact your local professional water treatment dealer . V alve Specifications Working Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20- 120 psi (1.38 - 8.27 bar) S tandard 12 V olt T ransformer Input Electr ...

メーカー GE カテゴリー Water Dispenser

GE 255 Valve / 400 Seriesのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 255 Valve / 400 Seriesの取扱説明書
- GEの製品カード
- パンフレット
- またはGE 255 Valve / 400 Seriesの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、GE 255 Valve / 400 Seriesの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、GE 255 Valve / 400 Seriesの取り付け説明書、サービスマニュアル、簡易説明書、またはGE 255 Valve / 400 Seriesのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、GE 255 Valve / 400 Seriesの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

GE 255 Valve / 400 Seriesデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGE 255 Valve / 400 Seriesを使用するのを助ける技術的文書のことです。説明書は通常、全てのGE 255 Valve / 400 Seriesユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

GEの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. GE 255 Valve / 400 Seriesの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGE 255 Valve / 400 Seriesの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。GE 255 Valve / 400 Seriesに関してこのドキュメントで見つけることができる全てのヒントの目次
3. GE 255 Valve / 400 Seriesデバイスの基本機能を使うにあたってのヒント。 GE 255 Valve / 400 Seriesのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。GE 255 Valve / 400 Seriesに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGE 255 Valve / 400 Seriesのメーカー/サービスへの連絡先に関する情報。

GE 255 Valve / 400 Seriesについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGE 255 Valve / 400 Seriesの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGE 255 Valve / 400 Seriesで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)