B&B Electronics RS-485の取扱説明書

39ページ 0.16 mb
ダウンロード

ページに移動 of 39

Summary
  • B&B Electronics RS-485 - page 1

    485SDA103798 Manual Cover Page B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 RS-485 Data Acquisition Module Model 485SDA10 Document No. 485SDA103798 This product Designed and Manufactured In Ottawa, Illinois USA of domestic and imported parts by B&B Electronics Mfg. Co. Inc. 7 ...

  • B&B Electronics RS-485 - page 2

    485SDA103798 Manual Table of Contents i B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Table of Contents Chapter 1- Introduction ........................................... 1 485SDA10 Features ...................................................... 1 Packing List ................... ...

  • B&B Electronics RS-485 - page 3

    ii Table of Contents 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Set Turn-around Delay Command ............................... 17 Read Module Configuration Command ........................ 17 Chapter 4 - A/D ................................................... ...

  • B&B Electronics RS-485 - page 4

    485SDA103798 Manual Table of Contents iii B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 TABLE 5.1 - DIGITAL I/O MASK VALUES .................................... 24 TABLE A-1 EXTENDED COMMANDS ........................................ A- 2 TABLE C-1: DECIMAL TO HEX TO ASCII TABLE .. ...

  • B&B Electronics RS-485 - page 5

    485SDA103798 Manual 1 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Chapter 1- Introduction 485SDA10 Features The 485SDA10 is a general purpose control module which operates through an RS-485 interface. The 485SDA10 offers 11 channels of 10-bit A/D (analog to digital), 3 digital in ...

  • B&B Electronics RS-485 - page 6

    2 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Figure 1.2 - General Block Diagram Packing List Examine the shipping carton and contents for physical damage. The following items should be in the shipping carton: • 485SDA10 unit • One 485SDA10 3.5” disk ? ...

  • B&B Electronics RS-485 - page 7

    485SDA103798 Manual 3 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Windows 3.11 1. Insert SDA Logger installation disk in your floppy drive. 2. Click the File Manager button. 3. Select the floppy drive containing the SDA Logger installation disk. 4. Double click the Setup.exe icon ...

  • B&B Electronics RS-485 - page 8

    4 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 variable resistor must be greater than 1k Ohms to limit the output current to 5mA. • Connect A/D Ref Input+ to +5V DC. • Connect A/D Ref Input- to analog ground (See Figure 1.3). • Connect the 485SDA10 to an ...

  • B&B Electronics RS-485 - page 9

    485SDA103798 Manual 5 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 485SDA10 Specifications Analog to Digital Converter Resolution: 10 bit Channels: 11 Reference Range: 5.0V DC max. (4.888 mV per bit) 2.5V DC min. (2.444 mV per bit) A/D Ref. Input - 0V DC to 2.5V DC A/D Ref. Input ...

  • B&B Electronics RS-485 - page 10

    6 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Chapter 2 - Connections This chapter will cover the connections required for the 485SDA10. There are four sets of connections: • A/D converter • Digital I/O • Serial port • Power supply Do not make any con ...

  • B&B Electronics RS-485 - page 11

    485SDA103798 Manual 7 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 A/D Ref Input - T he voltage connected to this pin determines the low end of the input voltage range. For proper operation, this pin must be connected to a DC voltage between 0 and +2.5 Volts. Typically, this is co ...

  • B&B Electronics RS-485 - page 12

    8 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Digital I/O Connections The digital I/O connectio ns are made on the I/O port, which is a DB-25S (female) connector. Table 2.1 shows the pinout of the I/O port. The next sections explain the functions and connecti ...

  • B&B Electronics RS-485 - page 13

    485SDA103798 Manual 9 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Digital Ground Connect the digital ground pin to your digital device's ground. To minimize noise, do not connect analog ground and digital ground together. Connect unused digital inputs to digital ground. Typi ...

  • B&B Electronics RS-485 - page 14

    10 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Serial Port Connections To communicate with the 485SDA10 module, it must be connected to an RS-422/RS-485 serial port. The 485SDA10 works with 2-wire or 4-wire RS-485. The unit automatically detects baud rates fr ...

  • B&B Electronics RS-485 - page 15

    485SDA103798 Manual 11 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Power Supply Connections The 485SDA10 requires 7 to 18 V DC at 30mA. Remember that the 30mA requirement doesn’t include the power consumption of any external devices. Therefore, any current sourced with the digi ...

  • B&B Electronics RS-485 - page 16

    12 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Chapter 3 - Commands There are only three commands required to control the 485SDA10: • Read A/D command • Read digital I/O command • Set output states command There are four commands used to configure the m ...

  • B&B Electronics RS-485 - page 17

    485SDA103798 Manual 13 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 The decimal and hexadecimal equivalents of some ASCII characters are shown in Table 3.2. Notice that the ASCII representation of the character “0” does not have a value of 0. Refer to Appendix C for more ASCII ...

  • B&B Electronics RS-485 - page 18

    14 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 The Read A/D channels command returns two bytes for each channel read. The two bytes represent the most significant byte (MSB) and least significant byte (LSB) of the reading. The MSB is received first, followed ...

  • B&B Electronics RS-485 - page 19

    485SDA103798 Manual 15 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Reading Digital I/O Command The Read Digital I/O command returns a byte which represents the states of the 3 digital input and 3 digital output states. Bits 3-5 correspond to the states of digital inputs 0-2. Bits ...

  • B&B Electronics RS-485 - page 20

    16 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Set Digital Output Command The Set Digital Output command is used to set the states of the 3 digital output lines. This command requires a data byte. The data byte is used to specify the output states. Bits 0-2 c ...

  • B&B Electronics RS-485 - page 21

    485SDA103798 Manual 17 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Set Power-up States Command The Set Power-up States command is used to set the st ates of the digital outputs at power-up. This command requires a data byte. The data byte is used to specify the power-up output st ...

  • B&B Electronics RS-485 - page 22

    18 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 { address}{ states}{ delay} Where {address} is a byte representing the module’s current address, {states} is a byte representing the module’s power-up states, and {delay} is a byte representing the module’s ...

  • B&B Electronics RS-485 - page 23

    485SDA103798 Manual 19 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Chapter 4 - A/D This chapter will deal with manipulating an A/D reading and cover some of the aspects that were not explained in the A/D Connections chapter. Sampling Rate The A/D converter has a conversion time o ...

  • B&B Electronics RS-485 - page 24

    20 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Data Range The data range of the A/D converter is determined by A/D Ref Input+ and A/D Ref Input- . A/D Ref Input- sets the bottom of the data range. Any input voltage that is less than or equal to the A/D Ref In ...

  • B&B Electronics RS-485 - page 25

    485SDA103798 Manual 21 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 The step size is also referred to as the resolution. Once the step size is known, all that is needed to determine the voltage of an A/D input is the number of steps. The data returned from the 485SDA10 is the numb ...

  • B&B Electronics RS-485 - page 26

    22 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Chapter 5 - Software This chapter covers programming techniques such as constructing a command string, receiving data and manipulating data. The various steps and examples are shown in QuickBasic. If you are prog ...

  • B&B Electronics RS-485 - page 27

    485SDA103798 Manual 23 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 ‘Get the value of channel 1 MSB$ = INPUT$ (1, #1) LSB$ = INPUT$ (1, #1) reading1 = (ASC(MSB$) * 256) + ASC(LSB$) ‘Get the value of channel 0 MSB$ = INPUT$ (1, #1) LSB$ = INPUT$ (1, #1) reading0 = (ASC(MSB$) * ...

  • B&B Electronics RS-485 - page 28

    24 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Table 5.1 - Digital I/O Mask Values Example 5.2 - Determining the status of Digital Input #1 of the module with and address of 10. mask = &H10 Command$ = “!” + CHR$( addr) + “RD” Print #1, Command$; R ...

  • B&B Electronics RS-485 - page 29

    485SDA103798 Manual 25 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 b) Set Appropriate Outputs LO W states = states AND (NOT(mask)) By “ ANDing” the current states with the complement of the appropriate mask of a digital output (given in Table 5.1), the output’s data bit wil ...

  • B&B Electronics RS-485 - page 30

    26 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Example 5.4 – Change the address of a model from 5 to 10. addr = 5 newaddr = 10 Command$ = “!” + CHR$( addr) + “SA” + CHR$( newaddr) Print #1, Command$ Set Power-up States Command The Set Power-up State ...

  • B&B Electronics RS-485 - page 31

    485SDA103798 Manual 27 B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 ‘ Clear bit 2 of states to make digital output 2 LO W states = states AND (NOT(4)) Command$ = “!” + CHR$( addr) + “SS” + CHR$(states) Print #1, Command$ At power-up digital output 0 will be HIGH, digital ...

  • B&B Electronics RS-485 - page 32

    28 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Read Module Configuration The Read Module Configuration command reads the 485SDA10’s address first, then the power-up states, and finally the turn-around delay. The steps to reading a module’s configuration a ...

  • B&B Electronics RS-485 - page 33

    485SDA103798 Manual Appendix A A- 1 B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Appendix A: Adding Data Field Confirmation W ith serial communications in a laboratory environment, the possibility of a communication error occurring is minimal. However, in a harsh or an industrial ...

  • B&B Electronics RS-485 - page 34

    A- 2 Appendix A 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Where “x” is the required data byte and “~” signifies the complement of the specified byte. Table A-1 Extended Commands Function Command Response Read A/D Channels #{ addr}RA{x}{~x} { chxmsb} ...

  • B&B Electronics RS-485 - page 35

    485SDA103798 Manual Appendix B B- 1 B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Appendix B: Analog Input Impedance When interfacing with an A/D converter, it is important that the device you are connecting can drive the A/D input. To determine if your device can drive an A/D inp ...

  • B&B Electronics RS-485 - page 36

    B- 2 Appendix B 485SDA103798 Manual B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Simplified Analog Input Analysis Using the equivalent circuit in Figure B-1, the time required to charge the analog input capacitance from 0 to Vs within ½ LSB can be derived as follows: The capacit ...

  • B&B Electronics RS-485 - page 37

    485SDA103798 Manual Appendix B B- 3 B&B Electronics - - 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Figure B-1. Equivalent Input Circuit Including the Driving Source ...

  • B&B Electronics RS-485 - page 38

    485SDA103798 Manual Appendix C C- 1 B&B Electronics - - PO Box 1040 -- Ottawa, IL 61350 PH (815) 433-5100 - - FAX (815) 434-7094 Appendix C: Decimal to HEX to ASCII Table Table C-1: Decimal to HEX to ASCII Table DECIMAL to HEX to ASCII CONVERSION TABLE DEC HEX ASCII KEY DEC HEX ASCII DEC HEX ASCII DEC HEX ASCII 0 0 NUL ctrl @ 32 20 SP 64 40 @ 9 ...

  • B&B Electronics RS-485 - page 39

    FCC Class A Equipm ent Stat ement FEDERA L COMM UNI CA TIONS COMM ISSION RA DIO FREQ UENCY I NTERFA CE STA T EMENT Class A Equipmen t This equipm ent has been tested and f ound to com ply with the limits for Clas s A digital device, pursuant to Par t 15 of the FCC Rules. T hese limits are designed to provide reas onable protection against harm ful ...

メーカー B&B Electronics カテゴリー Switch

B&B Electronics RS-485のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RS-485の取扱説明書
- B&B Electronicsの製品カード
- パンフレット
- またはB&B Electronics RS-485の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、B&B Electronics RS-485の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、B&B Electronics RS-485の取り付け説明書、サービスマニュアル、簡易説明書、またはB&B Electronics RS-485のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、B&B Electronics RS-485の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

B&B Electronics RS-485デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがB&B Electronics RS-485を使用するのを助ける技術的文書のことです。説明書は通常、全てのB&B Electronics RS-485ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

B&B Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. B&B Electronics RS-485の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははB&B Electronics RS-485の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。B&B Electronics RS-485に関してこのドキュメントで見つけることができる全てのヒントの目次
3. B&B Electronics RS-485デバイスの基本機能を使うにあたってのヒント。 B&B Electronics RS-485のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。B&B Electronics RS-485に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるB&B Electronics RS-485のメーカー/サービスへの連絡先に関する情報。

B&B Electronics RS-485についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもB&B Electronics RS-485の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがB&B Electronics RS-485で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)