  • Carrier 38YSA - page 1

    38YSA Split-System Heat Pump Installation and Start-Up Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or othe ...

  • Carrier 38YSA - page 2

    INSPECT EQUIPMENT File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit corner panel. It contains information needed to properly install unit. Check rating plate to be sure unit matches job specifications. Step 2 — Install on a Solid, Level Mounting Pad If conditions or local ...

  • Carrier 38YSA - page 3

    Step 6 — Thermostatic Expansion Valve For proper unit operation and reliability, units must be installed with field-supplied hard shutoff TXV. Do not install with evaporator coils having capillary tube metering devices or pistons. Due to system design, this unit must be installed with a factory-listed indoor section. Non-approved coils could caus ...

  • Carrier 38YSA - page 4

    For buried-line applications greater than 36 in., consult your local distributor. If refrigerant tubes or indoor coil are exposed to atmosphere, they must be evacuated to 500 microns to eliminate contamination and moisture in the system. OUTDOOR UNIT CONNECTED TO FACTORY-APPROVED INDOOR UNIT Outdoor unit contains correct system refrigerant charge f ...

  • Carrier 38YSA - page 5

    The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes. Failure to follow this warning can result in an electric shock, fire, or death. CONNECT GROUND AND POW ...

  • Carrier 38YSA - page 6

    Fig. 9 — Typical 24-v Circuit Connections using Carrier Model HP Thermostat with Fan Coils and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97536 24 VAC HOT R G W/W1 Y/Y2 O/W2 R W3 W2 RVS COOLING C B S1 S2 W2 CARRIER PROGRAMMABLE THERMOSTAT MODEL HP TWO OUTDOOR THERMOSTATS FA, FB, FC, FD, FF, FH FAN COIL HEAT PUMP G Y1/W ...

  • Carrier 38YSA - page 7

    Fig. 10 — Typical 24-v Circuit Connections using Other HP Thermostats with Fan Coils and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97404 24 VAC HOT R C W2 Y G R W3 W2 G RVS COOLING E W2 OTHER HP THERMOSTAT TWO OUTDOOR THERMOSTATS FA, FB, FC, FD, FF, FH FAN COIL HEAT PUMP C O R C O INDOOR FAN HEAT STAGE 2 COOL/HEAT STA ...

  • Carrier 38YSA - page 8

    Fig. 11 — Typical 24-v Circuit Connections using Carrier Model HP Thermostat with Smart Heat and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats and Carrier Model 2S Thermostat with FK4C Fan Coil and Intelligent Staging A97543 24 VAC HOT R G W/W1 Y/Y2 O/W2 RVS COOLING C B S1 S2 SUPPLEMENTAL HEATING RELAY CARRIER PROGRAMMABLE ...

  • Carrier 38YSA - page 9

    Fig. 12 — Typical 24-v Circuit Connections using Other HP Thermostats with Smart Heat and No Outdoor Thermostat, 1 Outdoor Thermostat, or 2 Outdoor Thermostats A97412 24 VAC HOT R C Y G O RVS COOLING W2 OTHER HP THERMOSTAT HEAT PUMP E R C Y G O W2T W3 W2D Y 0 R C O W2 Y INDOOR FAN EMERGENCY HEAT COOL/HEAT STAGE 1 24 VAC COM HEAT STAGE 2 CUT JW1 S ...

  • Carrier 38YSA - page 10

    WIRING DIAGRAM NOTES: 1. CARRIER THERMOSTAT WIRING DIAGRAMS ARE ONLY ACCU- RATE FOR MODEL NUMBERS BEGINNING WITH TSTA T_____ __ . 2. WIRING MUST CONFORM TO NEC OR LOCAL CODES. 3. SOME UNITS ARE EQUIPPED WITH PRESSURE SWITCH(ES), TEM- PERATURE SWITCH, OR 5-MINUTE COMPRESSOR CYCLE PRO- TECTION. CONNECT 24-V FIELD WIRING TO FACTORY- PROVIDED STRIPPED ...

  • Carrier 38YSA - page 11

    providing electrical potential to second heater sequencer (if used). If outdoor temperature falls below setting of outdoor thermostat (field-installed option), contacts close to complete circuit and bring on second bank of supplemental electric heat. When thermostat is satisfied, its contacts open, de-energizing contactor and sequencer. All heaters ...

  • Carrier 38YSA - page 12

    Step 14 — Final Checks IMPORTANT: Before leaving job, be sure to do the following: 1. Securely fasten all panels and covers. 2. Tighten service valve stem caps to 1/12-turn past finger tight. 3. Leave User ’ s Manual with owner. Explain system operation and periodic maintenance requirements outlined in manual. 4. Fill out Dealer Installation Ch ...

メーカー Carrier カテゴリー Heat Pump

Carrier 38YSAのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 38YSAの取扱説明書
- Carrierの製品カード
- パンフレット
- またはCarrier 38YSAの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Carrier 38YSAの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Carrier 38YSAの取り付け説明書、サービスマニュアル、簡易説明書、またはCarrier 38YSAのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Carrier 38YSAの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Carrier 38YSAデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCarrier 38YSAを使用するのを助ける技術的文書のことです。説明書は通常、全てのCarrier 38YSAユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Carrierの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Carrier 38YSAの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCarrier 38YSAの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Carrier 38YSAに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Carrier 38YSAデバイスの基本機能を使うにあたってのヒント。 Carrier 38YSAのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Carrier 38YSAに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCarrier 38YSAのメーカー/サービスへの連絡先に関する情報。

Carrier 38YSAについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCarrier 38YSAの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCarrier 38YSAで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)