    LMC5601C-VDSL2 HDMCII VDS L2 LAN Exte nd er Module (Extended Temp) Use exis ting phone-grade wi ring to suppor t high-bandwidth E t hernet connecti ons. ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 2

    FCC and IC RFI Statements Page 2 724-746-5500 | blackbox.com LMC5601C-VDSL2 FCC and Industry Canada RF Interference Statements Class B Digital Device. This equip ment has been tested and found to comply with the limits for a Class B computing de vice pursuant to Pa rt 15 of the FCC Rules. These limits a re designed to provide reasonable protection ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 3

    Certifications LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 3 Certifications European Directive 2002/96/EC (WEEE) requires that an y equipment that bears this symbol on produc t or packaging mu st not be dis posed of with unsorted municipal waste. This symbol indicates that the equipmen t should be disposed of separately from re gular household ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 4

    Table of Contents Page 4 724-746-5500 | blackbox.com LMC5601C-VDSL2 Table of Contents Part Numbers ......... ................. .............................................................. .............. 5 1. Specifications ....... .................................. .................................. .............. 6 2. Overview: About the HDMCII ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 5

    Part Numbers LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 5 Part Numbers Part Number Description LMC5601C-VDSL2 HD MCII VD SL2 LAN Extender Module (Extended Temp) ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 6

    Chapter 1: Specifications Page 6 724-746-5500 | blackbox.com LMC5601C-VDSL2 1. Specific ations DC Input 662 mA @ 5V Operating Temperature -40°F to +185°F (-40°C to +85°C) Storage Temperature -67°F to +257°F (-55°C to +125°C) Humidity 5% to 95% (non-c ondensing); 0 to 10,000 ft. altitude Dimensions Single Slot SNMP Manage able Modules ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 7

    Chapter 2: Overview LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 7 2. Overview: About the HDM CII VDSL2 LAN Extender Module (Extended Temp) HDMCII VDSL2 LAN Extender Module (Extended Temp) enables LAN and Campus network manager s, and service providers, to use an existing phone- grade wiring to support high bandwidt h Ethernet connecti ons. Indu ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 8

    Chapter 3: Configuration Page 8 724-746-5500 | blackbox.com LMC5601C-VDSL2 3. Configuration HDMCII VDSL2 LAN Extend er Module (Extended Te mp) includes various user-configurable features. These fe atures are selectable by us ing DIP Switches and software . Th e following sections d e scribe the DIP Switches for the Host CO and R emote CPE module co ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 9

    Chapter 3: Configuration LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 9 Swi t ch # Feature Function Default 1 HOST HOST=OFF / Remote=ON OFF 2 LFPT On= Link Fault Pass-Through Enabled OFF 3 FL ON= Fault Loopback Enabled OFF 4 Band Plan On= Asymmetric 998 with ISDN Off= Symmetric 997 w ith ISDN OFF 5 AN On= Auto Negotiation ON ON 6 Flow Control On ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 10

    Chapter 3: Configuration Page 10 724-746-5500 | blackbox.com LMC5601C-VDSL2 when Auto Nego tiation is not desire d by configuring usin g DIP Switches #8 and #9. 3.5 Auto Negotiation The HDMCII VDSL2 LA N Extender Module (Extend ed Temp) ships from the factory with Auto Negotiat ion enabled on the DATA po rt. In th is mode, the DATA port ne gotiates ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 11

    Chapter 3: Configuration LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 11 Traps can also be set in the iView 2 software. A Trap wi ll be ge nerated on any Loss of Signal (LOS); but more impor tantly, the end user can set a VDSL Quality Level that will generate a trap if the line fa ils below the assigned level. 3.8 LINK Quality Link Quality is de ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 12

    Chapter 3: Configuration Page 12 724-746-5500 | blackbox.com LMC5601C-VDSL2 3.10 Forcing the Data Port Speed The DATA port can be manually configur ed on HDM CII VDSL2 LA N Extender Module (Extended Temp) fo r 10 Mbps or 1 00 Mbps operation. Before manually setting th e speed, disable Au to N egotiation (S et DIP Sw itch #5 to the OFF position.) ? ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 13

    Chapter 4: Install the HDMCII VDSL2 LAN Extender Module (Extended Temp) LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 13 4. Install the HDMCII VDSL2 LAN Extender Module (Extended Tem p) Before installing an HDMCII VDSL2 LA N Extender Module (Ext ended Temp), set the options using the DIP Switches (r efer to the DIP Switch Se tting s section for m ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 14

    Chapter 5: Operation Page 14 724-746-5500 | blackbox.com LMC5601C-VDSL2 5. Operation 5.1 LED Operation Each module features diagno stic LEDs that provide information on featur es and ports. LED Function VDSL2 RAI The Remote Alarm Indication LED is YELLOW when the unit at the far end of the U nit has an ala rm FL Fault Loopback will be ON GREEN if t ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 15

    Chapter 5: Operation LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 15 5.2 Maximum Bandwidth HDMCII VDSL2 LAN Extender Module (Extended Temp) Link LEDs The standard single pair HDMCII VDSL2 LAN Ex tender Module (Extended Temp) unit will provide the following Ra te/Reach performance under the best conditions and still maintain a BER > 10^ -9 per ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 16

    Chapter 5: Operation Page 16 724-746-5500 | blackbox.com LMC5601C-VDSL2 When the Ethernet port is connected at 10BaseT, the VDSL2 line will be limited to 10 Mbps operati on and will indicate a RA NGE of 5500 fe et or less for all length lines. 5.3 RJ-45 Data Port Pinout (MDI) The following table lists the pin configuration for the RJ-45 Data connec ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 17

    Chapter 5: Operation LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 17 5.5 Link Fault Pass-Through LNK LNK TX LNK LNK TX LNK LNK TIP RIN G VDSL2 RIN G TIP VDSL2 RAI RAI FL LFPT FL LFPT B When a 10/100BaseT port is lost, the un it sends a fault signal (RAI) to the VDSL line. If the LFPT function is en abled at the Far End VDSL port receiving this f ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 18

    Chapter 6: Troubleshooting Page 18 724-746-5500 | blackbox.com LMC5601C-VDSL2 6. Troubleshooting The most common failure of a VDSL line is its slow degradation ov er time due to aging of the line or increased line noise as ad ditional servic e is added to the same Line bundle. To help detect th is degradation over time, the unit provides a user-def ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 19

    Chapter 7: Contacting Black Box LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 19 7. Contacting Bl ack Box Black Box Customer Service Order toll-free in the U.S.: Call 877-877 -BBOX (outside U.S. ca ll 724-746-5500) Free technical support, 24 hours a day, 7 days a week. Call: 724-746-5500 or Fax: 724-746-0746 Mail order: Black Box Corpora tion 100 ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 20

    Chapter 8: Fiber Optic Cleaning Guidelines Page 20 724-746-5500 | blackbox.com LMC5601C-VDSL2 8. Fiber Optic Cleaning Gu idelines Fiber Optic transmitt ers and receivers are extremely sus c eptible to contamination by particles of dirt or dust, which ca n obstruct the optic path and cause performa nce degr adation. Good s ystem performance requires ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 21

    Chapter 9: Electrostatic Discharge Precautions LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 21 9. Electrostatic Discharge Precautions Electrostatic discharge (ESD) can caus e damage to any product, add-in modules or stand alone units, contai ning electronic co mponents. Al ways observe the following prec autions when inst alling or handling thes ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 22

    NOTES ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 23

    NOTES LMC5601C-VDSL2 724-746-5500 | blackbox.com Page 23 ...

  • Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp) - page 24

    LMC5601C-VDSL2 Rev. 1 51-80970BB-00 Rev. A0 ...

メーカー Black Box カテゴリー Computer Hardware

Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HDMCII VDSL2 LAN Extender Module (Extended Temp)の取扱説明書
- Black Boxの製品カード
- パンフレット
- またはBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の取り付け説明書、サービスマニュアル、簡易説明書、またはBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)を使用するのを助ける技術的文書のことです。説明書は通常、全てのBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Black Boxの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)デバイスの基本機能を使うにあたってのヒント。 Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)のメーカー/サービスへの連絡先に関する情報。

Black Box HDMCII VDSL2 LAN Extender Module (Extended Temp)についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBlack Box HDMCII VDSL2 LAN Extender Module (Extended Temp)で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)