Miller Electric OM-2241の取扱説明書

32ページ 1.07 mb
ダウンロード

ページに移動 of 32

Summary
  • Miller Electric OM-2241 - page 1

    Visit our website at www.MillerWelds.com OM-2241 209 815E November 2004 Processes Description Gas Metal Arc (MIG) W elding Arc Welding Power Source Air Carbon Arc Cutting and Gouging Delta-Fab Flux Cored (FCA W ) W elding ...

  • Miller Electric OM-2241 - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric OM-2241 - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc W elding Hazards 1 . . . . . . . ...

  • Miller Electric OM-2241 - page 4

    Notes ...

  • Miller Electric OM-2241 - page 5

    OM-2241 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _8/03 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Watch Out ...

  • Miller Electric OM-2241 - page 6

    OM-2241 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z8 ...

  • Miller Electric OM-2241 - page 7

    OM-2241 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit. F ...

  • Miller Electric OM-2241 - page 8

    OM-2241 Page 4 1-5. Principal Safety Standards Safety i n W elding, Cutting, and Allied Processes, ANSI Standard Z49.1, from American W elding Society , 550 N.W . LeJeune Rd, Miami FL 33126 (phone: 305-443-9353, website: www .aws.org). Recommended Safe Practices for the Preparation for W elding and Cut- ting of Containers and Piping , American Weld ...

  • Miller Electric OM-2241 - page 9

    OM-2241 Page 5 SECTION 2 − CONSIGNES DE SÉCURITÉ − À LIRE A V ANT UTILISA TION som_fre 8/03 2-1. Signification des symboles Signifie « Mise en garde. Faire preuve de vigilance. » Cette procédure présente des risques identifiés par les symboles adjacents aux directives. Y Identifie un message de sécurité particulier . . Signifie « NOT ...

  • Miller Electric OM-2241 - page 10

    OM-2241 Page 6 Le rayonnement de l’arc génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) suscep- tibles de causer des brûlures oculaires et cutanées. Des étincelles sont projetées pendant le soudage. LES RA YONS DE L ’ARC peuvent c au- ser des brûlures oculaires et cuta- nées. D Porter u n masque de soudage ...

  • Miller Electric OM-2241 - page 11

    OM-2241 Page 7 2-3. Autres symboles relatifs à l’installation, au fonctionnement et à l’entretien de l’appareil. Risque D’INCENDIE OU D’EXPLO- SION D Ne pas placer l’appareil sur une surface inflam- mable, ni au−dessus ou à proximité d’elle. D Ne pas installer l’appareil à proximité de produits inflammables. D Ne pas surchar ...

  • Miller Electric OM-2241 - page 12

    OM-2241 Page 8 2-4. Principales normes de sécurité Safety in W elding, Cutting, and Allied Processes, norme ANSI Z49.1, de l’American W elding Society , 550 N. W . LeJeune Rd, Miami FL 33126 (téléphone : (305) 443−9353, site Web : www .aws.org). Recommended Safe Practices for the Preparation for W elding and Cut- ting of Containers and Pipi ...

  • Miller Electric OM-2241 - page 13

    OM-2241 Page 9 SECTION 3 − INST ALLA TION 3-1. Specifications V oltage Range Amperes Input at Rated Load Output, 60 Hz, Three-Phase Rated Welding Outpu t V oltage Range DC Max OCV DC 230 V 460 V 575 V KV A KW 375 A @ 35 V olts DC, 100% Duty Cycle 10 − 45 45 69 4* 34.5 2* 27.5 1.6* 27.5 1.61* 17.5 0.46* *While idling 3-2. Duty Cycle And Overheat ...

  • Miller Electric OM-2241 - page 14

    OM-2241 Page 10 3-3. V olt-Ampere Curves V olt-ampere curves show mini- mum and maximum voltage and amperage output capabilities o f unit. Curves of other settings fall be- tween curves shown. 209 81 1 0 10 20 30 40 50 60 0 100 200 300 400 500 600 700 800 DC Amperes DC V olts MAX MIN ...

  • Miller Electric OM-2241 - page 15

    OM-2241 Page 1 1 3-4. Selecting A Location 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side of unit. 3 Rating Label (Non CE Models Only) Use rating label to determine input power needs. Label located under front access door . 4 Plate Label (CE Models Only) Label l ...

  • Miller Electric OM-2241 - page 16

    OM-2241 Page 12 3-6. Dimensions And W eights Dimensions Dimensions A A 30 in (762 mm) including lift eye B 23 in (585 mm) B C C 30-1/2 in (775 mm) including strain relief F D 27-1/2 in (699 mm) F G H 4 Holes E 3/4 in (19 mm) 4 Holes F 21-1/8 in (537 mm) D G 1-1/8 in (29 mm) D H 7/16 in (1 1 mm) Dia W eight E 801 530 381 lb (173 kg) 3-7. 1 15 V AC R ...

  • Miller Electric OM-2241 - page 17

    OM-2241 Page 13 3-8. W eld Output T erminals And Selecting Cable Sizes T otal Cable (Copper) Length In W eld Circuit Not Exceeding 100 ft (30 m) Or Less 150 ft (45 m) 200 ft (60 m) 250 ft (70 m) 300 ft (90 m) 350 ft (105 m) 400 ft (120 m) Y T urn off power before connecting t o weld out- put terminals. Y Do not use worn, dam- aged, undersized, or p ...

  • Miller Electric OM-2241 - page 18

    OM-2241 Page 14 3-9. Remote 14 Receptacle RC8 Ref. 800 166-D Y T urn off power before con- necting to receptacle. 1 Remote 14 Receptacle RC8 Connect feeder to RC8. AJ B K I C L NH D M G E F 1 3-10. Remote 14 Receptacle RC8 Information Socket Information 24 VOL TS AC A 24 volts ac. Protected by circuit breaker CB2. 24 VOL TS AC B Contact closure to ...

  • Miller Electric OM-2241 - page 19

    OM-2241 Page 15 3-1 1. Electrical Service Guide Input V oltage 230 460 575 Input Amperes At Rated Output 69 34.5 27.5 Max Recommended Standard Fuse Rating In Amperes 1 Time-Delay 2 80 40 30 Normal Operating 3 100 50 40 Min Input Conductor Size In A WG 4 4 8 10 Max Recommended Input Conductor Length In Feet (Meters) 237 (72) 422 (129) 444 (135) Min ...

  • Miller Electric OM-2241 - page 20

    OM-2241 Page 16 3-13. Connecting Input Power 800 103-C / Ref. 801 1 16-A 3/8 in 3/8 in T ools Nee d e d : Y Installation must meet all National an d Local Codes − have only quali- fied persons make this installation. Y Disconnect and lockout/tagout in- put power before connecting input conductors from unit. Y Make input power connections to the w ...

  • Miller Electric OM-2241 - page 21

    OM-2241 Page 17 SECTION 4 − OPERA TION 4-1. Controls 209 383 3 1 V oltage Meter 2 Amperage Meter V oltmeter and ammeter display actual output voltage and amperage. 3 Power Switch With Indicator Light 4 High T emperature Shutdown Light Y W eld output studs are energized by controls on the wirefeeder . Y T urn Off power before connecting re- mote d ...

  • Miller Electric OM-2241 - page 22

    OM-2241 Page 18 5-2. Fuse F1 Ref. 800 101-C Y Disconnect input power be- fore opening rear access door . 1 Fuse Holder Cover 2 Fuse F1 (See Parts List For Rating) Fuse F 1 protects control transform- er from overload. If F1 opens, weld output and fan motor stops. Re- place F1. Close and secure access door . T ools Needed: 3/8 in 2 1 T urn Pull Out ...

  • Miller Electric OM-2241 - page 23

    OM-2241 Page 19 5-4. T roubleshooting T able T rouble Remedy No weld output; unit completely inoperative. Place line disconnect switch in On position (see Section 3-13 ). Check fuse F1, and replace if necessary (see Section 5-2). Check and replace line fuse(s), if necessary , or reset circuit breaker (see Section 3-13 ). Check for proper input powe ...

  • Miller Electric OM-2241 - page 24

    OM-2241 Page 20 SECTION 6 − ELECTRICAL DIAGRAM 218 521-A Figure 6-1. Circuit Diagram ...

  • Miller Electric OM-2241 - page 25

    OM-2241 Page 21 Notes ...

  • Miller Electric OM-2241 - page 26

    OM-2241 Page 22 SECTION 7 − PARTS LIST . Hardware is common and not available unless listed. 803 388-B 34 22 1 3 4 2 6 7 8 5 9 10 11 12 13 17 15 14 16 19 20 21 22 3 4 23 32 26 27 28 25 24 33 18 29 Figure 7-1 Main Assembly ...

  • Miller Electric OM-2241 - page 27

    OM-2241 Page 23 Description Part No. Dia. Mkgs. Item No. Quanti ty Figure 7-1 Main Assembly 1 +179 430 P ANEL, side 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 179 429 COVER, top 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric OM-2241 - page 28

    OM-2241 Page 24 Figure 7-2 Panel, Front w/Components (Fig 7-1 Item 33) Description Part No. Dia. Mkgs. Item No. Quanti ty 1 159 863 ELECTRONICS BOX 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PC1 209 627 CIRCUIT CARD, control (60Hz) 1 . . . . . . . . . . . . . . . ...

  • Miller Electric OM-2241 - page 29

    OM-2241 Page 25 Figure 7-2 Panel, Front w/Components (Fig 7-1 Item 33) (continued) Description Part No. Dia. Mkgs. Item No. Quant ity 14 +172 587 COVER, stud output 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 160 935 CLIP , spring 3 . . . . . . . . . . . . . . . ...

  • Miller Electric OM-2241 - page 30

    OM-2241 Page 26 Description Part No. Dia. Mkgs. Item No. Figure 7-4 Panel, Rear w/Components (Fig 7-1 Item 19) Quanti ty 1 173 283 CHAMBER, plenum 14 in 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 180 165 BLADE, fan 14 in 3wg 28deg .375 bore CCW 1 . . . . . . . . . . . . ...

  • Miller Electric OM-2241 - page 31

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 6/04 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric OM-2241 - page 32

    PRINTED IN USA  2004 Miller Electric Mfg. Co. 1/04 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 W es t Spencer St reet Applet on, W I 5 4914 USA International He adquarte rs− USA USA Phone: 920-735-4505 Auto-A t t ended USA & C anada F A X: 920-735-4134 Int ernational F A X : 9 20-735-4125 European Headqua rt ers − ...

メーカー Miller Electric カテゴリー Welder

Miller Electric OM-2241のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- OM-2241の取扱説明書
- Miller Electricの製品カード
- パンフレット
- またはMiller Electric OM-2241の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Miller Electric OM-2241の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Miller Electric OM-2241の取り付け説明書、サービスマニュアル、簡易説明書、またはMiller Electric OM-2241のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Miller Electric OM-2241の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Miller Electric OM-2241デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMiller Electric OM-2241を使用するのを助ける技術的文書のことです。説明書は通常、全てのMiller Electric OM-2241ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Miller Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Miller Electric OM-2241の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMiller Electric OM-2241の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Miller Electric OM-2241に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Miller Electric OM-2241デバイスの基本機能を使うにあたってのヒント。 Miller Electric OM-2241のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Miller Electric OM-2241に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMiller Electric OM-2241のメーカー/サービスへの連絡先に関する情報。

Miller Electric OM-2241についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMiller Electric OM-2241の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMiller Electric OM-2241で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)