    The world's first EOCR with built-in ZCT (bottom hole & terminal type) will save space, time and wiring through unique development design during installation. with compact size, possible to be applied to various panel size. the protection function added for high groud fault current. most suitable for low frequency circumstance (5Hz~, Invet ...

  • Schneider Electric EOCR-i3BZ - page 4

    Applications Building Office, commercial business, residence, school, hospital Industrial facilities Petrochemical, electronic, glass, steel, semiconductor, chemical, medicine, cement, paint ...

  • Schneider Electric EOCR-i3BZ - page 5

    Public institutions Gas, water supply and drainage, airport, train, port Control power ● 24 VDC ● 85~260 VAC/DC, 50/60 Hz Composition by function ● Earth Fault ● i3BZ, iFBZ (with Modbus RS-485) ● 3BZ2, FBZ2 (without Modbus RS-485) Contact contact ● A-Type ● 95-96(b), 97-98(a) : OL ● 57-58(a) : GR ● C-Type ● 95-96(b), 97-98(a) : ...

  • Schneider Electric EOCR-i3BZ - page 6

    6 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Earth fault detection by built-in ZCT Multifunctional motor protection for rated motor currents up to 80A (Definite Overcurrent protection) : Over ...

  • Schneider Electric EOCR-i3BZ - page 7

    7 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Item Operating Condition & Setting Range Operation Time Over Current (oc) Load current(In) exceeds threshold(Is) Definite(Def) : 0.2~30s Adjust ...

  • Schneider Electric EOCR-i3BZ - page 8

    8 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over Current Rated Setting Range(A) Definite TCC : 0.5~80A Inverse & th TCC : 0.5~32A *** CAUTION : Do not use any external CT Under Current Ra ...

  • Schneider Electric EOCR-i3BZ - page 9

    9 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Time-current characteristic cur ve 2. Definite characteristic 3. Inverse thermal characteristic (0.5~32A) 1. Inverse characteristic (0.5~32A) ...

  • Schneider Electric EOCR-i3BZ - page 10

    10 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over current and time setting tips ● Over current Setting tips in definite TCC mode 1. Over current threshold (OC) : - Set the OC at the rating ...

  • Schneider Electric EOCR-i3BZ - page 11

    11 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Front face 3 phase currents (In) and the leakage current are displayed every 2 seconds in sequence. Bar graph  it shows the load factor to OC s ...

  • Schneider Electric EOCR-i3BZ - page 12

    12 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT L1 current display 2sec 2sec 2sec 2sec L2 current display Rotate L3 current display GF current 3 phase digital ammeter function  Blocking displ ...

  • Schneider Electric EOCR-i3BZ - page 13

    1 Password 2 Selection of Phase 3 TCC Selection 4 Frequency 5 Fail Safe Reversed Phase 6 detection 7 Over Current Threshold 8 Start Delay Time 9 Over Current Duration Under Current 10 Threshold Under Current 11 Duration Earth Fault 12 (Ground Fault) Threshold 13 Earth Fault Duration 14 EF starting Delay 15 Phase Loss 16 Phase Loss Time 17 Unbalance ...

  • Schneider Electric EOCR-i3BZ - page 14

    Threshold of Alert output, set by % of the over current threshold (oc). If the load current is higher than this value, alert output(07-08 contact) is energized according to the setting of “ ALo:XX ” . If the load current is detected, alert output(07-08 contact) is energized. The alert threshold is no meaning for this operation. Refer to the Ale ...

  • Schneider Electric EOCR-i3BZ - page 15

    15 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Trip Indication Trip Indication after trip with UP/ DN button pressing Trip Cause Indication Contents of Indication L1 LED on L2 LED on L3 LED on ...

  • Schneider Electric EOCR-i3BZ - page 16

    16 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Wiring Examples EOCR-i3BZ/iFBZ OL : b, GR : a EOCR-i3BZ/iFBZ OL : 1a 1b, GR : 1a 3 phase line Diagram 3 phase line Diagram 3 phase line Diagram Si ...

  • Schneider Electric EOCR-i3BZ - page 17

    17 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Dimensions EOCR-i3BZ / 3BZ2 (Bottom Hole) EOCR-i3BZ / 3BZ2 (Teminal Type) 70 95 82 ∅ 4.5 6- M 4 21.4 21.4 108.1 45.3 53.3 91.3 3- ∅ 12 108.1 2 ...

  • Schneider Electric EOCR-i3BZ - page 18

    18 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Order Code i3BZ Intelligent, panel mounting unit  Basic Unit iFBZ Intelligent, flush mounting unit 3BZ2 Economic, panel mounting unit FBZ2 Econ ...

  • Schneider Electric EOCR-i3BZ - page 19

    19 Communication setting value Please set the Modbus communication parameters by PCON or HMI for the communication.  Slave address  Baud rate  Parity  Communication loss timeout Slave address The EOCR has slave addresses from 1 to 247. The factory default setting is 1. Baud rate The Communication speed provided is like below.  1.2kbp ...

  • Schneider Electric EOCR-i3BZ - page 20

    20 Communication Guide The standard connection conforms to the Modbus specifications, sepecially 2 wire multidrop serial bus diagram, presented at the website of Modbus.org in 2002 (Modbus_over_serial_line_V1.pdf, Nov.2002). Simple wiring diagram is like below. The characteristics is like below in case of a direct connection to the bus. Items Conte ...

  • Schneider Electric EOCR-i3BZ - page 21

    21 Communication Guide Bus connection thr ough a SCA type junction box 1. Master (PLC, PC or communication module) 2. Modbus cable (It is different according to the master side or a master having polarization combined to the other part of Bus) 3. Junction box 4. Modbus cable 5. Line terminators : 120 Ω - 0.25W Please use a cable with 2pair shiede ...

  • Schneider Electric EOCR-i3BZ - page 22

    Built_in ZCT catalog_EN ⓒ 2009 Samwha EOCR Ltd.-All rights reserved. 04/2009 Head Office 6 th floor, Jeil Bldg., 94-46, Youngdeungpo-Dong 7Ka, Youngdeungpo-Ku, Seoul, Korea Tel. 82 2 3473 2340 / Fax 82 2 3473 1159 Iksan Plant 574, Yongie-dong, Iksan-shi, Junbuk, Korea Tel. 82 63 835 5033 / Fax 82 63 835 4175 www.eocr.com ...

メーカー Schneider Electric カテゴリー Outboard Motor

Schneider Electric EOCR-i3BZのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EOCR-i3BZの取扱説明書
- Schneider Electricの製品カード
- パンフレット
- またはSchneider Electric EOCR-i3BZの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Schneider Electric EOCR-i3BZの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Schneider Electric EOCR-i3BZの取り付け説明書、サービスマニュアル、簡易説明書、またはSchneider Electric EOCR-i3BZのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Schneider Electric EOCR-i3BZの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Schneider Electric EOCR-i3BZデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSchneider Electric EOCR-i3BZを使用するのを助ける技術的文書のことです。説明書は通常、全てのSchneider Electric EOCR-i3BZユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Schneider Electricの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Schneider Electric EOCR-i3BZの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSchneider Electric EOCR-i3BZの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Schneider Electric EOCR-i3BZに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Schneider Electric EOCR-i3BZデバイスの基本機能を使うにあたってのヒント。 Schneider Electric EOCR-i3BZのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Schneider Electric EOCR-i3BZに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSchneider Electric EOCR-i3BZのメーカー/サービスへの連絡先に関する情報。

Schneider Electric EOCR-i3BZについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSchneider Electric EOCR-i3BZの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSchneider Electric EOCR-i3BZで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)