    Agilent E361xA 60W B ENCH SER IES DC POWER SUPPLIE S OPERA TING AN D SERVICE MANUAL FOR MODELS: Agilent E3614A Agilent E3615A Agilent E3616A Agilent E3617A Manual Pa rt No. 5959-5310 April 2000 Edition 8  1-1 ...

  • Agilent Technologies E3616A - page 2

    1-2 SA FETY SUMMA R Y The following gener al safety precautions m ust be observ ed during all phases of operat ion, service, and repair of this ins trumen t. Failure to c omply with these precaut ions or with s pecific warnings elsewher e in this manual violates sa fety standards of design , manufactur e, and int ended use of t he instrument . Agil ...

  • Agilent Technologies E3616A - page 3

    1-3 T able of Contents SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 INTRODUCTION . . . . . . . . . . . . . . . . . ...

  • Agilent Technologies E3616A - page 4

    1-4 GENERAL INFORMA TION INTROD UCTION This manual describes all models in the Agilent E361xA 60W Bench Power Supply family and unless stated otherwise, t he information in this manual applies t o all models. SAFETY REQUIREMENTS This produ ct is a Safety Class I instrument, w hich means that i t is p rovided with a protect ive eart h ground termina ...

  • Agilent Technologies E3616A - page 5

    1-5 b e g rounded or the power suppl y can be operated float- in g at up to a maximum of 240 V olts o f f g round. T otal out- put voltage to g round must not exceed 240 Vdc. LINE FUSE Line V oltage Fuse Agilent Part No. 100/ 1 15 V ac 2.0 A T 2 1 10-0702 230 V ac 1.0 A T 2 1 10-0457 SPECIFIC A TIONS Detailed specifications for the power suppl y ar ...

  • Agilent Technologies E3616A - page 6

    1-6 T able 1. Specifications and Operati n g Characteristics (Cont’d) *REMOTE PROGRAMMING SPEED Maximum time required for output volta g e to chan g e from initial value to within a tolerance band (0.1%) of the new l y pro g rammed value followin g the onset of a step chan g e in the pro g rammin g input volta g e. Full load No load Up: E3614A: 3 ...

  • Agilent Technologies E3616A - page 7

    1-7 e. Replace th e cover and mark the sup ply clearly wi th a t ag or label ind icating the co rrect line voltage and fuse th at is in use. Figure 2. Line V ol tage Selecto r (set for 1 15 V ac) Power Cord T o protect oper ating personnel, the instrument should be grounded. This instrument is equipped with a three conductor power cord. The third c ...

  • Agilent Technologies E3616A - page 8

    1-8 that the current limit value can be set from zero to maximum rated value. OPERA TING MODES The settin g of the rear panel switch determines the operatin g modes of the power suppl y . The local operatin g mode is set so the power suppl y senses the output volta g e directl y at the output terminals (local sensin g ) for operation usin g the fro ...

  • Agilent Technologies E3616A - page 9

    1-9 REMOTE OPERA TING MODES Remote operatin g modes discussed below are remote volta g e sensin g and remote volta g e pro g rammin g . Y ou can set up the unit for remote operatin g modes b y chan g in g the settin g s of the rear panel switch and connectin g the leads from the rear panel termi- nals to the load or the external volta g e. Solid co ...

  • Agilent Technologies E3616A - page 10

    1-10 pl y above 100% rated output. Limit y our pro g rammin g volta g e to 10 Vdc. Remote Pro g rammin g Connections. Remote pro g rammin g requires chan g in g settin g s of the switch and connectin g external volta g es to + and - terminals of "CV" or "CC" on the rear panel. An y noise picked up on the pro g rammin g leads wil ...

  • Agilent Technologies E3616A - page 11

    1-11 Settin g V olta g e and Current. T urn the slave unit's CURRENT control full y clockwise. Adjust the master unit's controls to set the desired output volta g e and current. The master suppl y operates in a completel y normal fashion and ma y be set up for either con- stant volta g e or constant current operation as required. V erif y ...

  • Agilent Technologies E3616A - page 12

    1-12 AUTO-SERIES OPERA TION Auto-series operation permits equal or proportional volta g e sharin g , and allows control of output volta g e from one master unit. The volta g e of the slaves is determined b y the settin g of the front panel VOL T AGE control on the master and volta g e divider resistor . The master unit must be the most positive sup ...

  • Agilent Technologies E3616A - page 13

    1-13 Remote Sensin g . T o remote sense with auto-series operation, set SENSE switch of the master unit and set SENSE switch of the slave unit to remote. Remote Analo g V olta g e Pro g rammin g . T o remote analo g pro- g ram with auto-series operation, connect pro g ram (external) volt- a g es to the "CV" or "CC"" termina ...

  • Agilent Technologies E3616A - page 14

    1-14 LOAD CONSIDERA TIONS This section provides information on operatin g y our suppl y with various t y pes of loads connected to its output. PULSE LOADING The power suppl y will automaticall y cross over from constant- volta g e to constant current operation in response to an increase (over the preset limit) in the output current. Althou g h the ...

  • Agilent Technologies E3616A - page 15

    A-1 SERVICE INFORMA TION Figure A -1. Block D iagram PRINCIPLES OF OPE R A TION (Block Diagram Overview ) Throughout t his discuss ion, refer to bot h the block d iagram of Figure A-1 and t he schematic diagrams at the rear of the manual. The input ac line voltage is first applied to the prereg- ulator w hich operates in c onjunction w ith the SCR ...

  • Agilent Technologies E3616A - page 16

    A-2 series pass transistors. Whenever the output volta g e is below the slopin g V1 line, the control circuit inhibits four SCRs and the input capacitors char g e to a volta g e determined b y N1. Fi g ure A-2 indicates the windin g s that are connected as a result of the other volta g e decisions. Fi g ure A-2. Output Power Plot The series re g ul ...

  • Agilent Technologies E3616A - page 17

    A-3 a . Perform turn-on checkout procedure g iven in pa g e 1-7. b . Perform the CV and CC Load Re g ulation perfor- mance tests g iven in the followin g para g raphs respectivel y . PERFORMANCE TESTS The followin g para g raphs provide test procedures for verif y- ing the power suppl y 's compliance with the specifications of T able 1. Please ...

  • Agilent Technologies E3616A - page 18

    A-4 CONST ANT VOL T AGE (CV) TESTS CV Setup. For all CV tests set the output current at full rated output to assure CV operation. The onset of constant current can cause a drop in output volta g e, increased ripple, and other performance chan g es not properl y ascribed to the con- stant volta g e operation of the suppl y . Load Regulation (Load Ef ...

  • Agilent Technologies E3616A - page 19

    A-5 Fi g ure A-5. Load T ransient Response Time W aveform P ARD(Ripple and Noise) Definition: P ARD is the Periodic and Random Deviation of the dc output volta g e from its avera g e value, over a specified bandwidth and with all other parameters maintained constant. Constant volta g e P ARD is measured in the root-mean- square(rms) or peak-to-peak ...

  • Agilent Technologies E3616A - page 20

    A-6 a. Connect the test equipment as shown in Fi g ure A-7. b. T urn the suppl y 's power on and turn CURRENT con- trol full y clockwise. c. T urn up output volta g e to the full rated value. Check that the suppl y 's CV indicator remains li g hted. Reduce VOL T AGE control if not li g hted. d. Set the oscilloscope to AC mode and bandwidt ...

  • Agilent Technologies E3616A - page 21

    A-7 e. Record output volta g e across Rs and convert it to current b y dividin g this volta g e b y Rs. f. Adjust autotransformer to the hi g h line volta g e (127 V ac for nominal 1 15 V ac, 1 10 V ac for nominal 100 V ac, and 253 V ac for nominal 230 V ac). g . When the readin g settles, record the volta g e across Rs a g ain and convert it curre ...

  • Agilent Technologies E3616A - page 22

    A-8 Ammeter and CC Set Calibration T o calibrate ammeter and CC set, proceed as follows: a. Connect test setup on Fi g ure A-9. b. T urn VOL T AGE and CURRENT control full y clock- wise. c. T urn on the suppl y and to calibrate ammeter adjust R5 on the displa y board until front panel AMPS dis- pla y reads exactl y DVM value divided b y Rs. d. T o ...

  • Agilent Technologies E3616A - page 23

    A-9 After the trouble has been isolated to one of the feedback loops, troubleshootin g can proceed as described in T a bles A- 4, A-5, or A-6. Series Re g ulatin g Feedback Loop. When troubleshootin g the series re g ulatin g loop, it is useful to open the loop since measurements made an y where within a closed loop ma y appear abnormal. With a loo ...

  • Agilent Technologies E3616A - page 24

    A-10 SYMPTOM CHECKS AND PROBABLE CAUSES Poor Load Re g ulation (Constant V olta g e) a. Refer to "Measurements T echniques" para g raph. b. Check +10 V reference volta g e. c. Ensure that the suppl y is not g oin g into current limit. Poor Load Re g ulation (Constant Current) a. Check +10 V reference volta g e. b. CR1, CR19, CR20, C2, C31 ...

  • Agilent Technologies E3616A - page 25

    A-11 STEP ACTION RESPONSE PROBABLE CAUSE 4 Check volta g e from pin 13 to pin 12 of U9. a. Measured volta g e is positive. b. Measured volta g e is ne g ative. a. Check U9A is defective. b. Check U10 and U9D is defective. Check R85 is open. 5 Check volta g e from pin 6 to pin 5 of U9. a. Measured volta g e is positive. b. Measured volta g e is ne g ...

  • Agilent Technologies E3616A - page 26

    A-12 REPL A CEA B LE P A R TS IN TRO DU CTI ON This section contains informat ion for ordering replacement parts. T able A-10 lists parts by reference designators and pro- vides the following information: a. Reference designat ors. Refer to T able A-8. b. Agilent T echnologies Part Number . c. T otal quantity us ed in that assembly. d. Description. ...

  • Agilent Technologies E3616A - page 27

    Table A-10. Replaceab le P arts List Reference Designator Agilen Part Number Q'ty Description Model Mfr. P/N Mfr. Code E3614A 1 60W BENCH POWER SUPPLY - E3614A MODEL E3615A 1 60W BENCH POWER SUPPLY - E3615A MODEL E3616A 1 60W BENCH POWER SUPPLY - E3616A MODEL E3617A 1 60W BENCH POWER SUPPLY - E3617A MODEL E3614-60005 1 MAIN BODY ASSY 14 28480 ...

  • Agilent Technologies E3616A - page 28

    Table A-10. Replaceab le P arts List (Con t'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code C18,21,24,27 0160-7077 4 CAP-FXD .1UF +-10% 630V POLYE-FL 14,15 28480 C19,22 0160-4822 2 CAP-FXD 1000PF +-5% 100V CER COG 14,15 28480 C20,23 0180-3970 2 CAP-FXD 1UF +-20% 50V AL-ELECTLT 14,15 28480 C28 0160-622 ...

  • Agilent Technologies E3616A - page 29

    Table A-10. Replaceab le P arts List (Con t'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code R24,26,27,37,38, 64,88,117,120 0757-0442 9 RESISTOR 10K +-1% .125W TF TC=0+-100 ALL 28480 R25,30,33 0698-8824 3 RESISTOR 562K +-1% .125W TF TC=0+-100 ALL 28480 R28,111 0698-3228 2 RESISTOR 49.9K +-1% .125W TF T ...

  • Agilent Technologies E3616A - page 30

    Table A-10. Replaceab le P arts List (Con t'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code R62 0698-8826 1 RESISTOR 825K +-1% .125W TF TC=0+-100 17 28480 R63 0698-8827 1 RESISTOR 1M +-1% .125W TF TC=0+-100 ALL 28480 R65 0757-0274 1 RESISTOR 1.21K +-1%.125W TF TC=0+-100 ALL 28480 R67 0757-0438 1 RESIS ...

  • Agilent Technologies E3616A - page 31

    Table A-10. Replaceab le P arts List (Con t'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code R115 0757-0463 1 RESISTOR 82.5K +-1% .125W TF TC=0+-100 15 28480 R115 0757-0462 1 RESISTOR 75K +-1% .125W TF TC=0+-100 16 28480 R115 0757-0461 1 RESISTOR 68.1K +-1% .125W TF TC=0+-100 17 28480 R116 0698-4489 1 ...

  • Agilent Technologies E3616A - page 32

    Table A-10. Replaceab le P arts List (Con t'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code CR21,22,23,24,25, 26,27,28,29,30 1901-0033 10 DIODE-GEN PRP 180V 200MA DO-35 ALL 1N645 27014 VR1,2,3 1902-0579 3 DIODE-ZNR 5.1V 5% PD=1W IR=10UA ALL 1N4733APL 04713 RT1,2 0837-0261 2 DIODE-VARISTOR ALL V275LA20 ...

  • Agilent Technologies E3616A - page 33

    Table A-11. Component Value Component Model E3614A E3615A E3616A E3617A C2 1000UF 25V +-20% AL-ELECTLT 470UF 50V +-20% AL-ELECTLT 330UF 50V +-20% AL-ELECTLT 220UF 100V +-20% AL-ELECTLT C7,8 39000UF 25V +-20% AL-ELECTLT 12000UF 63V +-20% AL-ELECTLT 5600UF 100V +-20% AL-ELECTLT 2700UF 160V +-20% AL-ELECTLT C11,16,17,25,26 0.01UF 100V +-10% CER X7R 0. ...

  • Agilent Technologies E3616A - page 34

    ...

  • Agilent Technologies E3616A - page 35

    ...

  • Agilent Technologies E3616A - page 36

    ...

  • Agilent Technologies E3616A - page 37

    ...

  • Agilent Technologies E3616A - page 38

    Manual Supple ment Suppleme nt Agile nt Part Number : 5 959-53 36, Edition 4 Supple ment Print Date : 14 April, 200 0 This supplement update s the following document: Agilen t E361XA 60W Series Lab Bench DC Power Supplie s Manual Agile nt Part Number : 5959-53 10 What is a manual suppleme nt? A manual suppleme nt keeps your manu al up-to-date. The ...

  • Agilent Technologies E3616A - page 39

    1-10-1 Voltage and Current Programming of the E3614A/15A/16A/ 17A with a Voltage and Current Source Remote analog voltage programming permits control of the regulated output voltage or current by means of a remotely varied voltage or current. The stability of the programming voltages directly affects the stability of the output. The voltage control ...

  • Agilent Technologies E3616A - page 40

    1-10-2 Programming V oltage Common to the Minus Output Figure 2 Set the CV switch down on the rear panel, and all others up. V in = 1/A x V out V out = A x V in Where V out is the power supply output voltage. V in is the programming voltage. A is the gain factor and the values of each model are as below . Alternative Voltage Programming Using Resis ...

  • Agilent Technologies E3616A - page 41

    1-10-3 Programming V oltage Common to the Minus Output Figure 4 The output will always be the same or less than the programming voltage. The M/S2 switch must be in the down position. For best results, place a 0.1 µ F capacitor in parallel with R2. V in = (R1  R2) / R2 x V out V out = R2 /  R1+R2) x V in Where V out is the power supply output ...

  • Agilent Technologies E3616A - page 42

    1-10-4 Constant Current Mode The E3614A/15A/16A/17A may be programmed for constant current with an analog voltage or current. Constant current with analog voltage programming can only be achieved with a voltage source that is common with the positive output terminal. Constant Current with V oltage Programming Figure 5 Set the CC switch down the rea ...

  • Agilent Technologies E3616A - page 43

    1-10-5 Figure 6 Set the CC switch down, and all others up. I in = 1/A x I out I out = A x V in Where I out is the power supply output current in amps. I in is the programming current in µ amps. A is the gain. Programming currents can be increased by adding a resistor across the CC+ and CC-. A 10 volts drop across R1 represents full scale current o ...

  • Agilent Technologies E3616A - page 44

    1-10-6 Voltage and Current Programming of the E3614A/15A/16A/17A with Resistors Remote programming with resistors permits control of the regulated output or current by means of a remotely varied resistor . The sum of the resistance of external programming resistors (R1 + R2) should be more than 40 kohm. T o have mor e pr ecise output voltage , use ...

  • Agilent Technologies E3616A - page 45

    1-10-7 Remote Resistor Programming, Constant Current Figure 8 Set the CC switch down on the rear panel, and all others up. I out = A x [V REF x {R/(R + R2 + 100)}] Where I out is the power supply output current. A is the gain factor and the values of each model are as below . V REF is between 10.1 1 V and 11.40 V . R = (92800 x R1)/(92800 + R1) R1 ...

  • Agilent Technologies E3616A - page 46

    CERTIFICATION Agilent T ec hnologies c ertifies that th is produ ct m et its published spe cifications at tim e of shipm ent f rom t he f actor y . Agilent T echno logies furt her c ert ifies th at its ca libration m easur eme nts are tr aceable to t he Unit ed St a tes Nat ional Ins titut e of Stan- dards and T echnology (fo rm erly National Bure ...

  • Agilent Technologies E3616A - page 47

    DECLARATION OF CONFORMITY According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014 Manufacturer’s Name: Manufacturer’s Address: Agilent Technologies, Inc. Power Products PGU 140 Green Pond Road Rockaway, New Jersey 07866 U.S.A Declares, that the product: Product Name: a) Single Output dc Power Supply (dual range) b) Single Output dc Power Supply ...

メーカー Agilent Technologies カテゴリー Power Supply

Agilent Technologies E3616Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- E3616Aの取扱説明書
- Agilent Technologiesの製品カード
- パンフレット
- またはAgilent Technologies E3616Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Agilent Technologies E3616Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Agilent Technologies E3616Aの取り付け説明書、サービスマニュアル、簡易説明書、またはAgilent Technologies E3616Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Agilent Technologies E3616Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Agilent Technologies E3616Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAgilent Technologies E3616Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのAgilent Technologies E3616Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Agilent Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Agilent Technologies E3616Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAgilent Technologies E3616Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Agilent Technologies E3616Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Agilent Technologies E3616Aデバイスの基本機能を使うにあたってのヒント。 Agilent Technologies E3616Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Agilent Technologies E3616Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAgilent Technologies E3616Aのメーカー/サービスへの連絡先に関する情報。

Agilent Technologies E3616Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAgilent Technologies E3616Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAgilent Technologies E3616Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)