  • METRObility Optical Systems R231-51 - page 1

    Installation & User Guide Models: R231-13 / R231-14 / R231-15 / R231-16 / R231-17 / R231-1J / R231-1X / R231-1Y / R231-47 / R231-49 / R231-51 / R231-53 / R231-55 / R231-57 / R231-59 / R231-61 R ADIANCE A CCESS L INE C ARDS RX LK FX S M LK RX 100 BASE RX LK FX RX LK T X 100 BASE RX LK FX S M RX LK T X 100 BASE T X T X MAN FD PWR MAN FD PWR MAN F ...

  • METRObility Optical Systems R231-51 - page 2

    This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or oth ...

  • METRObility Optical Systems R231-51 - page 3

    T able of Contents Radiance Access Line Cards Installation & User Guide Overview .............................................................................................................. 4 Installation Guide ............................................................................................... 6 STEP 1: Unpack the Line Cards ..... ...

  • METRObility Optical Systems R231-51 - page 4

    4 Overview Overview The Metrobility ® Radiance 100Mbps Access Line Cards ar e the industry’ s first media converters with the ability to reach across a wide area network (W AN) to communicate, test and reconfigure an unmanaged remote device, without reducing the available bandwidth to the customer site. This capability is accomplished through th ...

  • METRObility Optical Systems R231-51 - page 5

    Radiance Access Line Cards 5 The Radiance access line card provides the following key features: • Remote management using Metrobility’ s unique Radiance technology which enables communication with an unmanaged remote device. • Complete Remote Monitoring (RMON) Group 1 Ethernet Statistics support. • Remote link testing capability that does n ...

  • METRObility Optical Systems R231-51 - page 6

    6 Installation Guide Installation Guide Follow the simple steps outlined in this section to install and start using the Radiance access line cards. NOTE: Electr ostatic dischar ge pr ecautions should be taken when handling any line car d. Pr oper gr ounding is r ecommended (i.e., wear a wrist strap). Unpack the Line Cards Y our order has been provi ...

  • METRObility Optical Systems R231-51 - page 7

    Radiance Access Line Cards 7 * DIP switches can also be managed via console commands or through Metrobility’s NetBeacon or W ebBeacon management software. Refer to the Command Line Interface Reference Guide , NetBeacon Element Management Software Installation & User Guide or WebBeacon Management Software Installation & User Guide for soft ...

  • METRObility Optical Systems R231-51 - page 8

    8 Installation Guide Link Loss Carry Forward Link Loss Carry Forward (LLCF) is provided as an aid in troubleshoot- ing a remote connection. When LLCF is enabled, loss of the receive signal at the TX port prevents the FX port from transmitting an idle signal onto the cable. Conversely , if the FX port does not detect a receive signal, the TX port do ...

  • METRObility Optical Systems R231-51 - page 9

    Radiance Access Line Cards 9 • Grasp the card by the front panel as shown. • Insert the card into a slot in the chassis making sure that the top and bottom edges of the board are aligned with the top and bottom card guides in the chassis. Do not force the card into the chassis unneces- sarily . It should slide in easily and evenly . FX PWR RX R ...

  • METRObility Optical Systems R231-51 - page 10

    10 Installation Guide • Slide the card in until the top and bottom edges of the front panel are flush and even with the top and bottom edges of the chassis. • T o secure the line card to the chassis, turn the thumbscrew clockwise until it is snug. The card is now properly installed and ready for connection to the network. • It is not necessar ...

  • METRObility Optical Systems R231-51 - page 11

    Radiance Access Line Cards 11 The singlemode (SM) connector supports a maximum segment length of 20, 40, 60, or 100 km, depending on the model. NOTE: T o enable remote management, make sure the management (MAN) LED is ON after connecting the fiber cable to the remote access line card. If not, reset one of the access line cards via software or a pow ...

  • METRObility Optical Systems R231-51 - page 12

    12 User Guide User Guide This section contains information about the operating features of the Radiance access line cards. LED Indicators The Radiance access line cards provide several LEDs on the front panel for the visible verification of unit status and proper functionality . These LEDs can help with troubleshooting and overall network diagnosis ...

  • METRObility Optical Systems R231-51 - page 13

    Radiance Access Line Cards 13 Default Software Settings The following settings can only be changed via software commands. * Bandwidth Allocation .............................................................................. 100Mbps Maximum Burst Size ....................................................................................... 16K Loopbac ...

  • METRObility Optical Systems R231-51 - page 14

    14 User Guide The maximum burst size can be adjusted to one of the following settings: 16, 32, 64, 128 or 256 kilobytes. Loopback Mode Y ou can enable loopback on either port on the locally managed card or on the remote fiber port. The loopback function allows a port to return its incoming data back to the sender , while continuing to receive and t ...

  • METRObility Optical Systems R231-51 - page 15

    Radiance Access Line Cards 15 Disabling a port stops the data flow to and from that port. Although data is neither sent nor received, the disabled port continues to accept, process and transmit management packets. However , if LLCF is enabled and the opposite port has no link, management packets will not be transmitted. Remote Management Statistics ...

  • METRObility Optical Systems R231-51 - page 16

    16 User Guide Singlemode Fiber Optic Power Monitors Through software * , you can read the input and output power levels of the singlemode fiber optic port on the access line cards with diagnostic capabilities. Input Power Level The accuracy of the input power monitor is ± 1 dBm from -28 dBm to -12 dBm. The accuracy is ± 2 dBm from -31 dBm to -29 ...

  • METRObility Optical Systems R231-51 - page 17

    Radiance Access Line Cards 17 Link Loss Carry Forward (LLCF) * The access line cards incorporate an LLCF function for troubleshooting a remote connection. When LLCF is enabled, the ports do not transmit a link signal until they receive a link signal from the opposite port. The diagram below shows a typical network configuration with a good link sta ...

  • METRObility Optical Systems R231-51 - page 18

    18 User Guide Link Loss Return (LLR) The fiber optic ports of the access line cards have been designed with an LLR function * for troubleshooting a remote connection. When LLR is enabled, the fiber port’ s transmitter shuts down if its receiver fails to detect a valid receive link. LLR should only be enabled on one end of the link and is typicall ...

  • METRObility Optical Systems R231-51 - page 19

    Radiance Access Line Cards 19 T opology Solutions Radiance R5000 Remote Device Customer Premises CO/POP SNMP Control Remote Communications Path Status Reporting Configuration Instructions Used Bandwidth = 0 ...

  • METRObility Optical Systems R231-51 - page 20

    20 User Guide T echnical Specifications Data Rate Data Rate ____________________ 100Mbps half duplex, 200Mbps full duplex Bit Delay ____________________________________ 66 bits (fiber to copper) ____________________________________ 51 bits (copper to fiber) Network Connections Singlemode F/O Interface (R231-14, R231-16) Connector __________________ ...

  • METRObility Optical Systems R231-51 - page 21

    Radiance Access Line Cards 21 Singlemode CWDM F/O Interface (R231-47, -49, -51, -53, -55, -57, -59, -61) Connector _____________________________________________________ LC W avelength ________________________________________ (see tables below) Supported Link Length __________________________ up to 60 km full duplex Cable T ype _____________________ ...

  • METRObility Optical Systems R231-51 - page 22

    22 User Guide Product Safety , EMC and Compliance Statements This equipment complies with the following requirements: •U L • CSA • EN60950 (safety CE) • FCC Part 15, Class A • EN55022 Class A (emissions CE) • EN55024: 1998 (immunity) • DOC Class A (emissions) • Class 1 Laser Product This product shall be handled, stored and disposed ...

  • METRObility Optical Systems R231-51 - page 23

    Radiance Access Line Cards 23 Warranty and Servicing Three-Y ear W arranty for the Radiance Access Line Card Metrobility Optical Systems, Inc. warrants that every Radiance access line card will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipment. This warranty covers the original user o ...

  • METRObility Optical Systems R231-51 - page 24

    Product Manuals The most recent version of this manual is available online at http://www .metrobility .com/support/manuals.htm Product Registration T o register your product, go to http://www .metrobility .com/support/registration.asp 25 Manchester Street, Merrimack, NH 03054 USA tel: 1.603.880.1833 • fax: 1.603.594.2887 www .metrobility .com 566 ...

メーカー METRObility Optical Systems カテゴリー Network Card

METRObility Optical Systems R231-51のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- R231-51の取扱説明書
- METRObility Optical Systemsの製品カード
- パンフレット
- またはMETRObility Optical Systems R231-51の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、METRObility Optical Systems R231-51の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、METRObility Optical Systems R231-51の取り付け説明書、サービスマニュアル、簡易説明書、またはMETRObility Optical Systems R231-51のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、METRObility Optical Systems R231-51の製品を使用するにあたって最も人気のある説明書を閲覧できます。

METRObility Optical Systems R231-51デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMETRObility Optical Systems R231-51を使用するのを助ける技術的文書のことです。説明書は通常、全てのMETRObility Optical Systems R231-51ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

METRObility Optical Systemsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. METRObility Optical Systems R231-51の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMETRObility Optical Systems R231-51の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。METRObility Optical Systems R231-51に関してこのドキュメントで見つけることができる全てのヒントの目次
3. METRObility Optical Systems R231-51デバイスの基本機能を使うにあたってのヒント。 METRObility Optical Systems R231-51のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。METRObility Optical Systems R231-51に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMETRObility Optical Systems R231-51のメーカー/サービスへの連絡先に関する情報。

METRObility Optical Systems R231-51についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMETRObility Optical Systems R231-51の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMETRObility Optical Systems R231-51で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)