    Heat Controller , Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www .heatcontroller .com ENGINEERING DESIGN GUIDE HTV/HTD/HTH Series T wo-Stage Geothermal Heat Pumps 2 to 6 T ons ...

  • Heat Controller HTD SERIES - page 2

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 1         ? ...

  • Heat Controller HTD SERIES - page 3

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 2 T wo Stage Geothermal Heat Pump Systems Features of the T wo Stage HT Series The HT Series Geothermal Heat Pumps are some of the most efcient and innovative geothermal units on the market today . Packed with features, they offer the best value to the homeowner who is intereste ...

  • Heat Controller HTD SERIES - page 4

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 3 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems B?C7J;'7IJ;H";EJ>;H C7B#;7J*KCF-OIJ;CI ..  BB*HE:K9JI . ;9>D?97B"K?:;  J;CF;H7JKH;B;L;BI7D:BEM;HH;B7J?L ;>KC?:?JO ? ...

  • Heat Controller HTD SERIES - page 5

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 4 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 "-  ";D;I?I* 79A7=;:"--;H ?;I B?C7J;'7IJ;H  -C7H J ,;IFEDI?8B; EC<EH J78B;  -BEF;:H7?D*7DM?J>ED:;DI7J; )L;HY  EM-;DIEH 6 !?L; ...

  • Heat Controller HTD SERIES - page 6

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 5 HT Series Ratings ARI/ASHRAE/ISO 13256-1 at EWT (Entering Wat er T emperature) —HACR cir cuit breaker in USA only — All fuses class RK-5 —Wire length based on one wa y measurement with 2% voltage drop —Wire size based upon 60°C copper conductor and minimum cir cuit ampac ...

  • Heat Controller HTD SERIES - page 7

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 6 HT Series Ratings ARI/ASHRAE/ISO 13256-1 at EWT (Entering Wat er T emperature) —HACR cir cuit breaker in USA only — All fuses class RK-5 —Wire length based on one wa y measurement with 2% voltage drop —Wire size based upon 60°C copper conductor and minimum cir cuit ampac ...

  • Heat Controller HTD SERIES - page 8

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 7 TT 24 T r anquility 27™ (TT) Ser ies ClimateMaster : Smar t. Responsible . Comfor tab le . Dimensions — V er tical Upflow T r anquility 27™ V ertical Upflow Model Overall Cabinet A Width B Depth C Height 026 in cm 22.4 56.8 25.6 65.1 48.5 123.2 038 in cm 25.4 64.5 30.6 77 ...

  • Heat Controller HTD SERIES - page 9

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 8 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems ClimateMaster Geother mal Heat Pump Systems TT 25 All Products T echnical Guide: 2008 - 2009 Dimensions — V er tical Upflow T r anquility 27™ Access Panels Top View-Left Return Top View-Right Return U R S Isometric Vie ...

  • Heat Controller HTD SERIES - page 10

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 9 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 Dimensions – V er tical Downo w TT 26 T r anquility 27™ (TT) Ser ies ClimateMaster : Smar t. Responsible . Comfor tab le . Dimensions — V er tical Downflo w T ranquility 27™ V ertical Downflow Model Overall Cab ...

  • Heat Controller HTD SERIES - page 11

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 10 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems Dimensions – V er tical Downo w ClimateMaster Geother mal Heat Pump Systems TT 27 All Products T echnical Guide: 2008 - 2009 Dimensions — V er tical Downflo w T ranquility 27™ 2’ [61cm] Service Access Air Coil ...

  • Heat Controller HTD SERIES - page 12

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 11 Horizontal Model Overall Cabinet A Width B Depth C Height 024 in cm 22.4 56.8 62.2 158.0 19.3 48.9 036 in cm 25.4 64.5 71.2 180.8 21.3 54.0 048 in cm 25.4 64.5 76.2 193.5 21.3 54.0 060 in cm 25.4 64.5 81.2 206.2 21.3 54.0 070 in cm 25.4 64.5 81.2 206.2 21.3 54.0 Horizontal Model ...

  • Heat Controller HTD SERIES - page 13

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 12 Horizontal Model Discharge Connection Duct Flange Installed (+/- 0.10 in, +/- 2.5mm) Return Connection Standard Deluxe Filter Rack (+/- 0.10 in, +/- 2.5mm) M N O Supply Width P Supply Depth Q R S Return Depth T Return Height U V 024 in cm 3.6 9.3 2.0 5.1 12.5 31.8 15.5 39.4 3.6 ...

  • Heat Controller HTD SERIES - page 14

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 13 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 PERFORMANCE DATA HT024 Part Load Performance capacities shown in thousands of Btuh. 560 CFM Rated Airflo w COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW H ...

  • Heat Controller HTD SERIES - page 15

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 14 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems PERFORMANCE DATA HT024 Full Load Performance capacities shown in thousands of Btuh. 800 CFM Rated Airflow COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW HE ...

  • Heat Controller HTD SERIES - page 16

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 15 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 PERFORMANCE DATA HT036 Part Load Performance capacities shown in thousands of Btuh. 800 CFM Rated Airflow COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW HE ...

  • Heat Controller HTD SERIES - page 17

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 16 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems PERFORMANCE DATA HT036 Full Load Performance capacities shown in thousands of Btuh. 1200 CFM Rated Airflow COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW H ...

  • Heat Controller HTD SERIES - page 18

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 17 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 PERFORMANCE DATA HT048 Part Load Performance capacities shown in thousands of Btuh. 1050 CFM Rated Airflo w COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW ...

  • Heat Controller HTD SERIES - page 19

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 18 PERFORMANCE DATA HT048 Full Load Performance capacities shown in thousands of Btuh. 1600 CFM Rated Airflow COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW HE LAT COP HWG 20 12.0 4.8 11.0 32.1 3.09 21.6 88.6 3.04 3 ...

  • Heat Controller HTD SERIES - page 20

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 19 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 PERFORMANCE DATA HT060 Part Load Performance capacities shown in thousands of Btuh. 1350 CFM Rated Airflo w COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW ...

  • Heat Controller HTD SERIES - page 21

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 20 PERFORMANCE DATA HT060 Full Load Performance capacities shown in thousands of Btuh. 2000 CFM Rated Airflo w COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW HE LAT COP HWG 20 15.0 5.0 11.6 41.6 3.73 28.9 89.3 3.27 ...

  • Heat Controller HTD SERIES - page 22

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 21 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 PERFORMANCE DATA HT060 Part Load Performance capacities shown in thousands of Btuh. 1350 CFM Rated Airflo w COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW ...

  • Heat Controller HTD SERIES - page 23

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 22 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems PERFORMANCE DATA HT060 Full Load Performance capacities shown in thousands of Btuh. 2000 CFM Rated Airflo w COOLING - EAT 80°F DB / 67°F WB HEATING - EAT 70°F EWT °F GPM PSI FT TC SC Sens/Tot Ratio KW HR EER HWG HC KW ...

  • Heat Controller HTD SERIES - page 24

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 23 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 $,5:3.(7<3;0730,9:5;,905. 5;09 ' %6;(33. (7           "6>,9 ? ...

  • Heat Controller HTD SERIES - page 25

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 24 Heat Controller GeoMax 2 n Geother mal Heat Pump Systems Heat Controller • Geothermal Heat Pump Sy stems ClimateMaster Geother mal Heat Pump Systems TT 33 All Products T echnical Guide: 2006 - 2007 Blow er P erf or mance Data )09  .4)-4)2(4%2#.)+? ...

  • Heat Controller HTD SERIES - page 26

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 25 Geother mal Heat Pump Systems n Heat Controller GeoMax 2 B?C7J;'7IJ;H";EJ>;H C7B#;7J*KCF-OIJ;CI ..  BB*HE:K9JI . ;9>D?97B"K?:;  . H7DGK?B?JO W 'EDJHEB!;7JKH;I C ...

  • Heat Controller HTD SERIES - page 27

    Heat Controller , Inc. HT V/HTD/HTH SERIES Engineering Design Guide 26 Heat Contro ll er G eoMax 2  G eothe r m a l Heat P um p S y s tem s A uxiliar y Electric Heat TT 36 T r a n q u ilit y 27 ™ (TT) Se r i e s Cli m at e Ma s te r : Sm ar t. Res po ns i bl e . Co m fo r ta bl e . Auxiliar y Heat Electr ical Data Auxiliar y Heat Ratings Auxil ...

  • Heat Controller HTD SERIES - page 28

    Engineering Design Guide HT V/HTD/HTH SERIES Heat Controller , Inc. 27 T ypical Wiring Diagram HTV/HTD/HTH Units with CXM Board and ECM Fan Motor (single phase) ...

  • Heat Controller HTD SERIES - page 29

    04/2009 08/201 1 ...

メーカー Heat Controller カテゴリー Heat Pump

Heat Controller HTD SERIESのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HTD SERIESの取扱説明書
- Heat Controllerの製品カード
- パンフレット
- またはHeat Controller HTD SERIESの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Heat Controller HTD SERIESの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Heat Controller HTD SERIESの取り付け説明書、サービスマニュアル、簡易説明書、またはHeat Controller HTD SERIESのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Heat Controller HTD SERIESの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Heat Controller HTD SERIESデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHeat Controller HTD SERIESを使用するのを助ける技術的文書のことです。説明書は通常、全てのHeat Controller HTD SERIESユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Heat Controllerの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Heat Controller HTD SERIESの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHeat Controller HTD SERIESの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Heat Controller HTD SERIESに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Heat Controller HTD SERIESデバイスの基本機能を使うにあたってのヒント。 Heat Controller HTD SERIESのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Heat Controller HTD SERIESに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHeat Controller HTD SERIESのメーカー/サービスへの連絡先に関する情報。

Heat Controller HTD SERIESについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHeat Controller HTD SERIESの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHeat Controller HTD SERIESで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)