  • White Rodgers 1F82-0261 - page 1

    1 Blue 2” Heat Pump Ther mostat Heat Pump or Single Stage Installation and Operating Instructions Save these instructions f or future use! F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMA GE. APPLICA TIONS 1F82-0261 Thermostat Model Program ...

  • White Rodgers 1F82-0261 - page 2

    2 REMO VE OLD THERMOST A T 1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remov e the front cov er of the old thermostat. With wires still attached , remov e wall plate from the w all. If the old thermostat has a wall mounting plate, remov e the thermostat and the wall m ...

  • White Rodgers 1F82-0261 - page 3

    3 INST ALLA TION install fresh “AA” alkaline batteries immediately . For best results, use ne w premium brand alkaline batteries such as Duracell® or Energizer®. W e recommend replacing batteries e very 2 years. If the home is going to be unoccupied for an e xtended period (over 3 months) and is displa yed, the batteries should be replaced be ...

  • White Rodgers 1F82-0261 - page 4

    4 WIRING DIA GRAMS L R C SYSTEM MONITOR SWITCH G W2 Figure 4. T ypical wiring diagram for tw o transformer systems with saf ety circuits in BO TH systems Changeov er Relay* Y O/B Compressor Contactor * Changeover Rela y is energized in COOL when O/B s witch is in the “O” position Changeover Rela y is energized in HEA T when O/B switch is in the ...

  • White Rodgers 1F82-0261 - page 5

    5 The confi guration menu allo ws you to set certain ther mostat operating characteristics to your system or personal requirements. T o enter the menu: Set your thermostat to OFF and press the and b uttons simultaneously . The display will show the fi rst item in the confi guration menu. Press R UN/HOLD to change to the ne xt menu item or press ...

  • White Rodgers 1F82-0261 - page 6

    6 Emergency System EMER bypasses the Heat Pump to use the heat source wired to terminal W2 on the ther mostat. EMER is typically used when compressor operation is not desired, or y ou prefer bac k-up heat only . 1. Mo ve SYSTEM s witch to EMER position, EMER will fl ash on the displa y . 2. Press to adjust the thermostat above room temperature . T ...

  • White Rodgers 1F82-0261 - page 7

    7 Do not allow the compressor to run unless the compressor oil heaters ha ve been operational for 6 hours and the system has not been operational f or at least 5 minutes. CA UTION ! MANU AL OPERA TION • HOLD TEMPERA TURE — With the SYSTEM s witch set to HEA T or COOL , momentarily press R UN/HOLD button. HOLD will be displa yed. Use or to adjus ...

  • White Rodgers 1F82-0261 - page 8

    8 PR OGRAMMING Enter Heating Program 1. Mov e the SYSTEM switch to HEA T . 2. Press PRGM once. “Mo T u We Th Fr” (indicating weekda y program) will appear in the displa y . Also displa yed are the currently programmed start time for the 1st heating period and the currently programmed temper ature (fl ashing). EXAMPLE: This display windo w show ...

  • White Rodgers 1F82-0261 - page 9

    9 TR OUBLESHOO TING Reset Operation If a voltage spik e or static discharge blanks out the displa y or causes erratic thermostat operation, reset the ther mostat by pressing the , and PRGM buttons sim ultaneously . If the thermostat has power , has been reset and still does not function correctly contact your heating/cooling service person or place ...

  • White Rodgers 1F82-0261 - page 10

    10 ST A GING Second Stage - A uxiliary Heat Most heat pump systems hav e an A uxiliar y or Second Stage electric heater or gas fur nace. Heat produced by a heat pump is economical but ma y not alwa ys ha ve the capacity to maintain a comf or table room temperature setting. Auxiliary/Second Stage heat is usually less economical but the added heat ca ...

  • White Rodgers 1F82-0261 - page 11

    11 NO TES ...

  • White Rodgers 1F82-0261 - page 12

    12 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mar k of Emerson Electric Co. Homeowner Help Line: 1-800-284-2925 www .white-rodgers.com ...

メーカー White Rodgers カテゴリー Thermostat

White Rodgers 1F82-0261のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 1F82-0261の取扱説明書
- White Rodgersの製品カード
- パンフレット
- またはWhite Rodgers 1F82-0261の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、White Rodgers 1F82-0261の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、White Rodgers 1F82-0261の取り付け説明書、サービスマニュアル、簡易説明書、またはWhite Rodgers 1F82-0261のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、White Rodgers 1F82-0261の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

White Rodgers 1F82-0261デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWhite Rodgers 1F82-0261を使用するのを助ける技術的文書のことです。説明書は通常、全てのWhite Rodgers 1F82-0261ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

White Rodgersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. White Rodgers 1F82-0261の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWhite Rodgers 1F82-0261の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。White Rodgers 1F82-0261に関してこのドキュメントで見つけることができる全てのヒントの目次
3. White Rodgers 1F82-0261デバイスの基本機能を使うにあたってのヒント。 White Rodgers 1F82-0261のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。White Rodgers 1F82-0261に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWhite Rodgers 1F82-0261のメーカー/サービスへの連絡先に関する情報。

White Rodgers 1F82-0261についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWhite Rodgers 1F82-0261の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWhite Rodgers 1F82-0261で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)