  • Bloomfield 9010 - page 1

    PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD , LLC 2 ERIK CIRCLE, P . O. Box 280 V erdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www .wellsbloomfield.com p/n 75815 Rev. F ECN-13387 M601 07 1112 cps OWNERS MANUAL for INTEGRITY ™ DECANTER COFFEE BREWERS MODELS 9010 9012 9016 Includes: Installation Use & Care Servicing Instr ...

  • Bloomfield 9010 - page 2

    601 75815 Owners Manual Integrity Decanter Brewers NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1 ...

  • Bloomfield 9010 - page 3

    TABLE OF CONTENTS Thank You for purchasing this Wells Bloomfield appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life. This manual contains the information needed to properly install this appliance, and to use, ...

  • Bloomfield 9010 - page 4

    FEATURES AND OPERAT ING C ONT ROLS Fig. 1 Features & Operating Controls 2 601 75815 Owners Manual Integrity Decanter Brewers ...

  • Bloomfield 9010 - page 5

    PRECAUTIONS AND GE NERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to no n-in sulat ed components must be performed by qualified service personnel. Do not open a ny access pan els which requi re t he use of tools. Failure to heed this warning can result in electrical sho c k. WARNING: INJURY HAZARD All installation p ...

  • Bloomfield 9010 - page 6

    INSTALLATION INSTRUCTIO NS READ THIS CAREFULL Y BEFORE ST ARTING THE I NST ALLA TION Unpack the unit. Inspect all component s for completeness and condition. Ensure that all packing materials have bee n remove d from the unit. Verify that the Spray Head Gasket and Spray Disk are prop erly installed. LEVELING THE UNIT Verify that an adjustable leg i ...

  • Bloomfield 9010 - page 7

    INSTALLATION INSTRUCTIO NS (co ntinued) NOTE: This equipment m ust be installed to comply with applicable federal, state and local plumbing codes and ordinances. WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line wil l provide such a ground. Electrical shock will cause death or ser ...

  • Bloomfield 9010 - page 8

    OPERATION Fig. 4 Brewer Operation Diagram A. START-UP For initial start-up, or if the bre we r ha s n ot been used for an extended period of time: ♦ Be sure spray disk and brew gasket are prop erly installe d in the brew head. ♦ Be sure the water sup ply is properly conne cted and the water supply valve is turned ON . ♦ Be sure the WATER TANK ...

  • Bloomfield 9010 - page 9

    OPERATION (continued) WATER HEATER Water temperature is sen s ed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, which controls line power to the heating element. The setpoint temperature is adjustable at the thermostat. The element is protected from over- temperature by a hi-limit thermostat. WATER F ...

  • Bloomfield 9010 - page 10

    BREWING COFFEE CAUTION: BURN HAZARD Exposed surfaces of the brewer, brew chambe r and decanter may be HOT to the touch, and can cause serious burn s. CAUTION: BURN HAZARD To avoid splashing or over- flowing hot liquids, ALWAYS place an empty decanter under the brew chamber before starting the brew cycle. Failure to comply can cause serious burns. C ...

  • Bloomfield 9010 - page 11

    CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect br ewer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush. 1. Disconnect brewer from electric power. Allow brewer to cool before cleaning. 2. Remove and empty decanters. 3. Remove and empty brew cham ...

  • Bloomfield 9010 - page 12

    10 TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power sup ply cord Check / reset cir cuit breaker Set for desired temperature Allow to cool Reset hi-limit (8786, 8788) Examine wiring & connectors, thermostat and heating element Repair/replace as neede d Be sure to add sufficient water prior to energizing Increase water amount Adjust amoun ...

  • Bloomfield 9010 - page 13

    SERVICING INSTRUCTIONS ACCESS PANELS Each warmer plate has a center stud wh ich screws int o a bracket. Warmer plates on Canadian br ewe rs are secured with a nut. Remove button plug on bottom of brewer to access nut on main warmer. Remove top panel to access nuts o n top wa rmers. Remove warmer plates by turning count er-clockwise. Solenoid door i ...

  • Bloomfield 9010 - page 14

    SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord o r turn circuit breaker OFF. Remove top panel. Pull vent tube out of tank lid and insert a thermometer of known accuracy in vent hole. Reconnect brewer to elect rica l powe r. Place an empty decanter under bre w ch ambe r. Energize brewer and pour one decanter (64 oz.) of ...

  • Bloomfield 9010 - page 15

    SERVICING INSTRUCTIONS (continued) 13 601 75815 Owners Manual Integrity Decanter Brewers IMPORTANT: Water p ressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure exceeds this value, or if water pressure varies greatly, a pressure regulator must be installed in the water supply line. IMPORTANT: Before setting assembly in ...

  • Bloomfield 9010 - page 16

    SERVICING INSTRUCTIONS (continued) 14 REPLACE HEATING ELEMENT Remove tank lid assembly as described on pag e 13. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemb le in revers e order. REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuou sly from bre w head. NOTE ...

  • Bloomfield 9010 - page 17

    SERVICING INSTRUCTIONS (continued) 15 IMPORTANT: When repl acing water faucet coil, also replace seal gaskets. NOTE: Any abrasion or roughness on the flat end of the seat cup will require replacing the seat cup: Work the seat cup out of the bonnet and off of the end of the stem. Install a new seat cup, making sure the knob on the stem is fully inse ...

  • Bloomfield 9010 - page 18

    CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never siphon deliming chemicals or soluti o ns by mouth. This operation should only be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, splash or pour water or deli ming solution in ...

  • Bloomfield 9010 - page 19

    7. Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then reinstall the hold-down strap. 8. Reinstall wiring to heating element and thermostat. Reinstall the hi-limit thermostat (if removed). For brewers with hot water faucet, reassemble faucet piping. Verify that all internal c ...

  • Bloomfield 9010 - page 20

    EXPLODED VIEW & PARTS LIST 18 HOT WATER TANK ASSEMBLY 601 75815 Owners Manual Integrity Decanter Brewers 68 56 57 58 63 56 61 50 52 62 55 54 70 66 66a 13 67 66b 59 60 14 AL TERNA TE 50 ITEM P ART NO. DESCRIPTION USED ON 13 8043-5 HOLD -DOWN STRAP 9010, 9012(CA), 9016(EX) 50 8512-51 86280 THERMOSTAT (BLACK BODY - INCL. SEAL & MOUNTING SCREWS ...

  • Bloomfield 9010 - page 21

    EXPLODED VIEW & PART S LIST (continued) 19 601 75815 Owners Manual Integrity Decanter Brewers 33 34 25 24 34a 19 43 26 28 11 27 29 60 8 10 12 45 9 29a 29b 29c 29d 29e 29f 29g 29h 29j 29k T ANK ASSY see P AGE 18 61 59 18 CABINET PLUMBING CO MPONENTS ITEM PART NO. DESCRIPTI ON USED ON 8 8540-3 FORMED TUBE, FAUCET OU TLET ASSEMBL Y 10-7/8" LO ...

  • Bloomfield 9010 - page 22

    EXPLODED VIEW & PART S LIST (continued) 20 601 75815 Owners Manual Integrity Decanter Brewers ELECTRICAL COMPONENTS ITEM P ART NO. DESCRIPTION USED ON 2 8572-18 8533-32 HEATING ELEMENT, WARMER 120V 100W HEATING ELEMENT, WARMER 220V 85W / 240V 100W ALL EXCEPT 9016(EX) 9016(EX) 30 6710-23 8563-110 SWITCH, WARMER ON/OFF 120V SWITCH, WARMER ON/OFF ...

  • Bloomfield 9010 - page 23

    EXPLODED VIEW & PART S LIST (continued) CABINET COMPONENTS 21 601 75815 Owners Manual Integrity Decanter Brewers ITEM PART NO. DESCRIPTION USED ON 3 8700-16 COVER PLA TE, WARMER BLACK 9010, 9012 (CA), 9016(EX) 33 8543-42 GASKET, SPRAY HEAD 9010, 9012(CA), 9016(EX) 34 82727 SPRA Y DISK, EMBOSSED 9010, 9012(CA), 9016(EX) 34a 8543-45 RETAINER, SPR ...

  • Bloomfield 9010 - page 24

    WIRING DIAGRAMS 22 601 75815 Owners Manual Integrity Decanter Brewers 123 123 123 READY LIGHT BREW SWITCH WARMER SWITCH WARMER SWITCH WARMER SWITCH SOLENOID THERMOST A T TIMER HI-LIMIT BLACK BLACK ORANGE ORANGE BLACK BLACK BLACK BLACK RED GREEN WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE BLUE BROWN BROWN MAIN WARMER TOP REAR WARMER TOP FRONT WA ...

  • Bloomfield 9010 - page 25

    WIRING DIAGRAMS ( continued) 23 601 75815 Owners Manual Integrity Decanter Brewers TIMER GREEN LINE LINE NEUT GND 123 123 123 READY LIGHT BREW SWITCH WARMER SWITCH WARMER SWITCH WARMER SWITCH SOLENOID BLACK BLACK BLACK BLACK RED BROWN BROWN WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE WHITE BLUE BROWN MODEL 9016 RED 12 ga ORANGE ORANGE MAI ...

  • Bloomfield 9010 - page 26

    Genuine Parts Protect - YOU - All - W ays SER VICE TRAINING - QUALITY SERVICE SER VICE TRAINING - QUALITY SERVICE CUSTOMER SA TISF ACTION CUSTOMER SA TISF ACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association Commercial Food Equipment Service Association PRINTED IN UNITED ST A TES OF AMERICA WELLS BLOOMFIELD , ...

メーカー Bloomfield カテゴリー Coffeemaker

Bloomfield 9010のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 9010の取扱説明書
- Bloomfieldの製品カード
- パンフレット
- またはBloomfield 9010の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bloomfield 9010の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bloomfield 9010の取り付け説明書、サービスマニュアル、簡易説明書、またはBloomfield 9010のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bloomfield 9010の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bloomfield 9010デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBloomfield 9010を使用するのを助ける技術的文書のことです。説明書は通常、全てのBloomfield 9010ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bloomfieldの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bloomfield 9010の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBloomfield 9010の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bloomfield 9010に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bloomfield 9010デバイスの基本機能を使うにあたってのヒント。 Bloomfield 9010のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bloomfield 9010に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBloomfield 9010のメーカー/サービスへの連絡先に関する情報。

Bloomfield 9010についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBloomfield 9010の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBloomfield 9010で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)