American Dynamics RJ856UDの取扱説明書

10ページ 1 mb
ダウンロード

ページに移動 of 10

Summary
  • American Dynamics RJ856UD - page 1

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 1 of 10 RS-422 Single-Position Junction Box (J-Box) Installation Guide Figure 1. RS-422 J-Box RJ856UD and RJ856UD-1 Series This weather-tight box (Figure 1) provides Class 2 LPS power and data to the new SpeedDome Ultra outdoor camera housing. IMPORTANT: Read Regula ...

  • American Dynamics RJ856UD - page 2

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 2 of 10 RS-422 Single-Position J-Box Specifications REG ID: SV JBOX1 Product Codes RJ856UD .............................. 120V with North American line cord RJ856UD-1 ........................... 230V with Continental European line cord Transformer primary jumpers an ...

  • American Dynamics RJ856UD - page 3

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 3 of 10 Mounting the J-Box This section explains how to mount the J-box to a wall or pole. Parts Required Installation Kit (0351-1646-01) includes: Item Qty Part Number Screw, Self-tapping, 4.8x25, PHP 4 5810-5081-111 Anchor Bolt, ¼-20x2¼, w/Hardware 4 2880-0011 A ...

  • American Dynamics RJ856UD - page 4

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 4 of 10 Outdoor Pole Mounting Outdoor mounting (Figure 3) requires that PC board, chassis, and power cord be removed to facilitate attachment to pole. PC board and chassis are reattached once box is secured. Note: Pole Mount Kit RHOPM, supplied with the pole mount s ...

  • American Dynamics RJ856UD - page 5

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 5 of 10 Connecting AC Power The J-box comes wired for 120Vac and has a 2m (6ft-7in) SJT 3-conductor power cord attached. Plug the cord into a dedicated 24-hour, unswitched outlet. If the box is to be driven by 240Vac, then the power cord (if used) and jumpers across ...

  • American Dynamics RJ856UD - page 6

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 6 of 10 6. Run conduit and ac cable to box and clamp conduit in place (Figure 7). 7. Reattach transformer chassis. Figure 7. Conduit attachment 8. Wire ac line to TB1 and jumper primary taps of transformer according to ac source (refer back to Figure 6). 120Vac: Pla ...

  • American Dynamics RJ856UD - page 7

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 7 of 10 Procedure 1. Turn power switch in J-box to off (0). Power LED should be off. 2. Route power and data cables through one of two extra strain relief fittings in bottom of box. 3. Connect low-voltage ac and data wires to connector TB2 (Figure 8). Color code sho ...

  • American Dynamics RJ856UD - page 8

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 8 of 10 Troubleshooting Problem Possible Solution No Power First check both fuses, then look for open or loose wire connections at TB1. If loose, reconnect wires. Measure voltage across 0 and 24V taps of secondary winding on transformer. If open, replace transformer ...

  • American Dynamics RJ856UD - page 9

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. H INSTALLATION GUIDE 9 of 10 Ordering Parts Only the following parts can be ordered: • RS-422 PC Board 0312-0163-02 • Power Transformer 5604-0205-01 • Cable Strain Relief 3100-0035-11 • Fuse 5111-0017-21. These parts are shown bold in Figure 13. Figure 13. Exploded view of RS-42 ...

  • American Dynamics RJ856UD - page 10

    RS-422 SINGLE-POSITION JUNCTION BOX (J-BOX) 8000-2573-20, REV. G INSTALLATION GUIDE 10 of 10 Declarations This product can only be used with American Dynamics products and other approved products from Sensormatic Electronics Corporation. When the unit is hard wired, the disconnect device (circuit breaker) must be readily accessible. To meet regulat ...

メーカー American Dynamics カテゴリー J-Box

American Dynamics RJ856UDのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- RJ856UDの取扱説明書
- American Dynamicsの製品カード
- パンフレット
- またはAmerican Dynamics RJ856UDの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、American Dynamics RJ856UDの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、American Dynamics RJ856UDの取り付け説明書、サービスマニュアル、簡易説明書、またはAmerican Dynamics RJ856UDのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、American Dynamics RJ856UDの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

American Dynamics RJ856UDデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAmerican Dynamics RJ856UDを使用するのを助ける技術的文書のことです。説明書は通常、全てのAmerican Dynamics RJ856UDユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

American Dynamicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. American Dynamics RJ856UDの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAmerican Dynamics RJ856UDの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。American Dynamics RJ856UDに関してこのドキュメントで見つけることができる全てのヒントの目次
3. American Dynamics RJ856UDデバイスの基本機能を使うにあたってのヒント。 American Dynamics RJ856UDのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。American Dynamics RJ856UDに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAmerican Dynamics RJ856UDのメーカー/サービスへの連絡先に関する情報。

American Dynamics RJ856UDについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAmerican Dynamics RJ856UDの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAmerican Dynamics RJ856UDで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)