Desa CHDV37N/Pの取扱説明書

38ページ 0.99 mb
ダウンロード

ページに移動 of 38

Summary
  • Desa CHDV37N/P - page 1

    DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL CHDV37N/P(A,B) AND CHDV41N/P(A,B) Save this manual for future reference. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch • Do not use any phone in your building. • Immediately call your gas supplier fro ...

  • Desa CHDV37N/P - page 2

    2 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used. 2. For propane/LP fireplace, do not place propane/LP supply tan ...

  • Desa CHDV37N/P - page 3

    3 105542 OWNER’S MANUAL REMOTE OFF ON PRODUCT IDENTIFICA TION Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA-B149 [.1 or .2] Installation Codes (Canada) . *Available from: American National Standards ...

  • Desa CHDV37N/P - page 4

    4 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) Fireplace size D x FW x RW 37" 18 1 / 2 " 37" 14" 41" 18 1 / 2 " 41" 18" PRE-INST ALLA TION PREP ARA TION LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Comfort Glow direct-ve ...

  • Desa CHDV37N/P - page 5

    5 105542 OWNER’S MANUAL C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 W all 29" 13" 10 1 / 4 " 8 3 / 4 " 37" 41" 37 1 / 2 " 41 1 / 2 " 58" 9 1 / 4 " 41" Note : Where two numbers are given the top number is exclusive to the 37" Fireplace and the bottom number is exclusive to the 41&q ...

  • Desa CHDV37N/P - page 6

    6 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or b ...

  • Desa CHDV37N/P - page 7

    7 105542 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage or loss of life. WARNING: Seal all ve ...

  • Desa CHDV37N/P - page 8

    8 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstr ...

  • Desa CHDV37N/P - page 9

    9 105542 OWNER’S MANUAL UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 12 - Vent Opening Requirements 3. Attach vent pipe assembly to the fire- place. Set fireplace in front of it’ s per- manent location to in ...

  • Desa CHDV37N/P - page 10

    10 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) VENTING INST ALLA TION Continued UP UP Horizontal V enting V ertical (V) Horizontal (H) 37" min. 10" max. Figure 16 - Horizontal Termination Configuration for Rigid Venting Figure 17 - Horizontal Termination Configuration for Rigid Venting Using One ...

  • Desa CHDV37N/P - page 11

    11 105542 OWNER’S MANUAL VENTING INST ALLA TION Continued UP V enting with T wo 90 ° Elbo ws V ertical (V) Horizontal (H 1 ) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' min. 20' max. 20' max. 8' max ...

  • Desa CHDV37N/P - page 12

    12 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 21). Whenever possible, use 45 ° elbows instead of 90 ? ...

  • Desa CHDV37N/P - page 13

    13 105542 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 23 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 24 - Installed Cathedral Ceiling Support Box Vertical Termination Configurations Figures 25 through 28 show four different configurations for vertical ...

  • Desa CHDV37N/P - page 14

    14 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) V er tical V enting V = 40' max. Figure 28 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 9 0 ° Elbo ws V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' ma ...

  • Desa CHDV37N/P - page 15

    15 105542 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Comfort Glow direct-vent fireplace has been AGA tested and approved for elevations from 0-2000 feet and CGA certi- fied for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the ...

  • Desa CHDV37N/P - page 16

    16 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) INSTALLING OPTIONAL BLOWER ACCESSORY IMPORTANT : For clarity, gas valve assem- bly and grate/burner assembly are not shown in Figures 30 through 33, page 17. They will, however, be in your fireplace when you are installing the blower. Also for clarity the fir ...

  • Desa CHDV37N/P - page 17

    17 105542 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued WARNING: Never touch the blower wheel while in operation. 10 . Peel off the backing paper and stick the supplied wiring diagram decal on the firebox bottom approximately 3" to the right of the blower speed control bracket (Figure 33). WARNING: Failure to position the parts in accord ...

  • Desa CHDV37N/P - page 18

    18 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) Figure 35 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your retailer. CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certa ...

  • Desa CHDV37N/P - page 19

    19 105542 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.5 kPa) will damage fireplace gas regulator . 2. Cap of f open end of gas pipe where manual shutoff valve ...

  • Desa CHDV37N/P - page 20

    20 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) FIREPLACE INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close manual shutoff valve (see Fig- ure 37). 2. Pressurize supply piping system by ei- ther opening propane/LP supply tank valve for propane/LP gas fireplace or ope ...

  • Desa CHDV37N/P - page 21

    21 105542 OWNER’S MANUAL FIREPLACE INST ALLA TION Continued Continued WIRELESS HAND-HELD REMOTE CONTROL (Included) Installing Battery into Receiver 1. Open bottom louver and locate the switch bracket on the left. 2 . Unscrew the switch bracket. Lean bracket forward so you are able to ac- cess the back of the remote receiver . 3. Locate the batter ...

  • Desa CHDV37N/P - page 22

    22 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) INSTALLING OPTIONAL BRICK LINER CD8037A/ CD8041 WARNING: If fireplace has been running, turn off and un- plug fireplace. Let cool before installing brick liner. This brick liner kit is optional. You may purchase brick liner from your local retailer or see Acc ...

  • Desa CHDV37N/P - page 23

    23 105542 OWNER’S MANUAL WARNING: The glass door must be securely in place before running this fireplace. Do not run this fireplace if glass is missing or broken. FIREPLACE INST ALLA TION Continued Figure 46 - Installing Log No. 1 Figure 47 - Installing Log Assembly No. 2 Figure 48 - Installing Log Assembly No. 3 Figure 49 - Placing Ember Materia ...

  • Desa CHDV37N/P - page 24

    24 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) OPERA TING FIREPLACE WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, f ...

  • Desa CHDV37N/P - page 25

    25 105542 OWNER’S MANUAL TEMP ST ATUS HI LO MAN ON AUT O OFF OPERA TING FIREPLACE Continued Figure 52 - Hand-Held Thermostat Remote Control Unit Selections (GHRCT) Increases Room Temperature Decreases Room Temperature Turns Burners On and Off Shows Current Operation Mode Shows Temperature Setting Allows Burner(s) to be Turned On and Off with the ...

  • Desa CHDV37N/P - page 26

    26 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) BURNER FLAME PATTERN Burner flames will be steady; not lifting or floating. Flame patterns will be different from unit to unit and will vary depending on installation type and weather conditions. If the vent configuration is installed incor- rectly, the flame ...

  • Desa CHDV37N/P - page 27

    27 105542 OWNER’S MANUAL PILOT AND BURNERS • Remove ember material before cleaning burners and replace when cleaning is complete. • Burner and controls should be cleaned with compressed air to remove dust, dirt, or lint. • Use a vacuum cleaner or small, soft bristled brush to remove excess dust, dirt, or lint. LOGS • If you remove logs fo ...

  • Desa CHDV37N/P - page 28

    28 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean pilot. This can damage pilot unit. POSSIBLE CAUSE 1. Ignito ...

  • Desa CHDV37N/P - page 29

    29 105542 OWNER’S MANUAL OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking noise just after burners are lit or shut off Remote does ...

  • Desa CHDV37N/P - page 30

    30 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone ...

  • Desa CHDV37N/P - page 31

    31 105542 OWNER’S MANUAL SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply might be low (propane/LP units only) When Gas Quality Is Bad • pilot will not stay lit • burners will produce flames and soot • firepl ...

  • Desa CHDV37N/P - page 32

    32 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) SPECIFICA TIONS CHDV37N(A,B) CHDV37P(A,B) CHDV41N(A,B) CHDV41P(A,B) Btu 17,000/24,000 Btu/h 17,000/22,000 Btu/h 18,000/26,000 Btu/h 19,000/24,000 Btu/h Gas Type Natural Propane/LP Natural Propane/LP Ignition Piezo Piezo Piezo Piezo Manifold Pressure 3.5" ...

  • Desa CHDV37N/P - page 33

    33 105542 OWNER’S MANUAL ACCESSORIES Purchase these fireplace accessories from your local retailer. If they can not supply these accessories, call DESA International’s Sales Department at 1-800-432-2382. for information. You can also write to the ad- dress listed on the back page of this manual. BRASS PERIMETER TRIM KIT CD9037(37")/GA7091( ...

  • Desa CHDV37N/P - page 34

    34 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) AUTO M AN O FF STATUS O N LO HI TEM P REMOTE OFF ON 28 5 44 1 2 3 4 5 6 5 5 7 7 8 9 10 1 1 (Included in Hardware Pack) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 6 6 38 32 33 34 35 59 36 33 37 39-2 39-3 39-1 42 43 45 48 47 46 49 50 51 52 53 54 5 ...

  • Desa CHDV37N/P - page 35

    35 105542 OWNER’S MANUAL P ARTS LIST DIRECT-VENT FIREPLACE CHDV37N(A,B) CHDV41N(A,B) This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 31 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 104547-02 Top Outer Casing-37" 1 104547-03 Top Outer Ca ...

  • Desa CHDV37N/P - page 36

    36 105542 DIRECT -VENT FIREPLACE (NA TURAL/ PROP ANE/LP) CHDV37N/P(A,B) AND CHDV41N/P(A,B) AUTO MAN OFF STATUS ON LO HI TEMP REMOTE OFF ON 28 5 44 1 2 3 4 5 6 5 5 7 7 8 9 10 1 1 (Included in Hardware Pack) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 30 31 6 6 38 32 33 34 35 59 36 33 37 39-2 39-3 39-1 42 43 45 48 47 46 49 50 51 52 53 54 54 55 ...

  • Desa CHDV37N/P - page 37

    37 105542 OWNER’S MANUAL KEY NO. PART NUMBER DESCRIPTION QTY. 1 104547-02 Top Outer Casing-37" 1 104547-03 Top Outer Casing-41" 1 2 104474-02 Outer Casing-37" 1 104474-03 Outer Casing-41" 1 3 104548-02 Bottom Outer Casing-37" 1 104548-01 Bottom Outer Casing-41" 1 4 104479-04BR Firebox Assembly-37" 1 104479-01BR ...

  • Desa CHDV37N/P - page 38

    LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the ...

メーカー Desa カテゴリー Outdoor Fireplace

Desa CHDV37N/Pのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CHDV37N/Pの取扱説明書
- Desaの製品カード
- パンフレット
- またはDesa CHDV37N/Pの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Desa CHDV37N/Pの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Desa CHDV37N/Pの取り付け説明書、サービスマニュアル、簡易説明書、またはDesa CHDV37N/Pのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Desa CHDV37N/Pの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Desa CHDV37N/Pデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDesa CHDV37N/Pを使用するのを助ける技術的文書のことです。説明書は通常、全てのDesa CHDV37N/Pユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Desaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Desa CHDV37N/Pの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDesa CHDV37N/Pの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Desa CHDV37N/Pに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Desa CHDV37N/Pデバイスの基本機能を使うにあたってのヒント。 Desa CHDV37N/Pのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Desa CHDV37N/Pに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDesa CHDV37N/Pのメーカー/サービスへの連絡先に関する情報。

Desa CHDV37N/Pについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDesa CHDV37N/Pの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDesa CHDV37N/Pで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)