Porter-Cable 70-200の取扱説明書

21ページ 1.97 mb
ダウンロード

ページに移動 of 21

Summary
  • Porter-Cable 70-200 - page 1

    INSTRUCTION MANUAL P ART NO. A10355 - 04-06-05 Copyright © 2005 Delta Machinery ESP AÑOL: PÁGINA 21 T o learn more about DEL T A MACHINER Y visit our website at: www .deltamachinery .com. For Parts, Service, W arranty or other Assistance, please call 1-800-223-7278 ( In Canada call 1-800-463-3582). 20" Drill Pr ess (Model 70-200) ...

  • Porter-Cable 70-200 - page 2

    2 T ABLE OF CONTENTS Read and understand all warnings and operating instructions before using any tool or equipment. When using tools or equipment, basic safety precautions should always be followed to r educe the risk of personal injury . Improper operation, maintenance or modification of tools or equipment could r esult in serious injury and prop ...

  • Porter-Cable 70-200 - page 3

    3 Indicates an imminently hazardous situation which, if not avoided, will r esult in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could r esult in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, may r esult in minor or moderate injury . Used without the saf ...

  • Porter-Cable 70-200 - page 4

    4 GENERAL SAFETY RULES READ AND UNDERST AND ALL W ARNINGS AND OPERA TING INSTRUCTIONS BEFORE USING THIS EQUIPMENT . Failure to follow all instructions listed below , may result in electric shock, fire, and/or serious personal injury or pr operty damage. IMPORT ANT SAFETY INSTRUCTIONS 1. FOR YOUR OWN SAFETY , READ THE INSTRUCTION MANUAL BEFORE OPERA ...

  • Porter-Cable 70-200 - page 5

    5 ADDITIONAL SPECIFIC SAFETY RULES F AILURE TO FOLLOW THESE RULES MA Y RESUL T IN SERIOUS INJUR Y . 1. DO NOT OPERA TE THIS MACHINE until it is completely assembled and installed according t o the instructions. A machine incorrectly assembled can cause serious injury . 2. OBT AIN ADVICE fr om your supervisor , instructor , or another qualified pers ...

  • Porter-Cable 70-200 - page 6

    6 A separate electrical circuit should be used for your machines. This cir cuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cor d is used, use only 3-wire extension cor ds which have 3- prong gr ounding type plugs and matching receptacle which will accept the machine’ s plug. Before connec ...

  • Porter-Cable 70-200 - page 7

    7 EXTENSION CORDS Use proper extension cor ds. Make sure your extension cor d is in good condition and is a 3-wire extension cord which has a 3-pr ong grounding type plug and matching r eceptacle which will accept the machine’ s plug. When using an extension cord, be sur e to use one heavy enough to carry the current of the machine. An undersized ...

  • Porter-Cable 70-200 - page 8

    8 FOREWORD The Delta Model 70-200 Drill Press pr ovides production capacity drilling and includes; 1 hp single phase 115/230 volt induction motor , pulleys, belts, 0 - 5/8 ″ capacity chuck, 45 degree tilt table L/R, rack and pinion table raising mechanism and #3 Morse T aper spindle adaptor . A quick release motor mount makes changing the nine sp ...

  • Porter-Cable 70-200 - page 9

    9 CAR TON CONTENTS UNP ACKING AND CLEANING Carefully unpack the machine and all loose items fr om the shipping container(s). Remove the protective coating fr om all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone, gasoline or lacquer thinner for this purpose). After cleaning, cover the u ...

  • Porter-Cable 70-200 - page 10

    10 Fig. 16 Fig. 17 Fig. 18 MOUNTING THE MACHINE 1. If your drill press is to be used in one permanent location, the drill press base must be secur ed to the supporting surface with fasteners through the four mounting holes, (A) Fig. 16, in the drill press base. IF YOU DO NOT F ASTEN YOUR DRILL PRESS IN A PERMANENT MANNER, THE DRILL PRESS MUST BE F ...

  • Porter-Cable 70-200 - page 11

    11 Fig. 2 Fig. 3 ASSEMBLING THE DRILL PRESS 1. Assemble column (A) Fig. 2, to base (B) using four M 12 x 45mm long hex head screws (thr ee of which are shown at [C]). Loosen set screw in collar (D) and r emove collar (D) and raising rack (E). 2. Remove bolt (F) Fig. 3, and remove table (G) fr om table bracket (H). H G F B C A E D THE PL YWOOD BASE ...

  • Porter-Cable 70-200 - page 12

    12 Fig. 4 3. Assemble worm gear (J) Fig. 4, to the inside of hole (K) in table bracket (H). 4. Thread table lock lever (M) Fig. 4, into hole in table bracket, as shown. Fig. 5 Fig. 6 5. Place raising rack (E) Fig. 5, in position inside table bracket (H) making sure gear on inside of table bracket is engaged with teeth of raising rack. 6. Slide tabl ...

  • Porter-Cable 70-200 - page 13

    13 8. Reassemble collar (D) Fig. 7, which was removed in STEP 1 , to column. IMPORT ANT : Bottom of collar (D) MUST NOT be pushed all the way down onto top of raising rack (E). MAKE SURE top of raising rack (E) is under bottom of collar (D) and that there is enough clearance to allow rack (E) to rotate ar ound the column. Then tighten set screw (Q) ...

  • Porter-Cable 70-200 - page 14

    14 Fig. 11 11. Place the drill press head on column, as shown. Line up head with base and tighten two head locking screws (R) Fig. 11. 12. Thread the three pinion wheel handles (Z) Fig. 12, into the three thr eaded holes in the pinion shaft, as shown. 13. Make certain the tapered hole in the bottom of the spindle (T) Fig. 13, and the taper on the s ...

  • Porter-Cable 70-200 - page 15

    15 OPERA TIONAL CONTROLS AND ADJUSTMENTS Fig. 23 ST AR T/STOP CONTROLS The start/stop buttons are located on the fr ont of the drill press head. T o start the machine, press the start button (A) Fig. 23, and to stop the machine, press the stop button (B). MAKE SURE THA T THE BUTTON IS IN THE “STOP” POSITION BEFORE PLUGGING IN THE POWER CORD. IN ...

  • Porter-Cable 70-200 - page 16

    16 Fig. 27 Fig. 28 Fig. 29 DRILLING HOLES TO DEPTH Where a number of holes ar e to be drilled to exactly the same depth, a depth stop is provided in the pinion shaft housing (A) Fig. 27, and is used as follows: 1. Loosen lock lever (B) Fig. 27, and rotate housing (A) until the pointer (C) lines up with the depth indicated on the English/Metric scal ...

  • Porter-Cable 70-200 - page 17

    17 Fig. 30 T ABLE ADJUSTMENTS 1. The table can be raised or lowered on the column by loosening table clamp handle (A) Fig. 29, and turning the table raising and lowering handle (B). After the table is at the desired height, tighten handle (A). 2. The table can be tilted right or left by pulling out and removing table alignment pin (C) Fig. 30, and ...

  • Porter-Cable 70-200 - page 18

    18 BORING IN WOOD T wist drills, although intended for metal drilling, may also be used for boring holes in wood. However , machine spur bits are generally pr eferred for working in wood; they cut a squar e bottom hole and are designed for r emoval of wood chips. Do not use hand bits which have a screw tip; at drill pr ess speeds they turn into the ...

  • Porter-Cable 70-200 - page 19

    19 DRILLING MET AL Use clamps to hold the work when drilling in metal. The work should never be held in the bare hand; the lips of the drill may seize the work at any time, especially when breaking thr ough the stock. If the workpiece is whirled out of the operator’ s hand, he may be injur ed. In any case, the drill will be broken when the work s ...

  • Porter-Cable 70-200 - page 20

    20 P AR TS, SERVICE OR WARRANTY ASSIST ANCE All Delta Machines and accessories are manufactur ed to high quality standards and ar e serviced by a network of Porter -Cable • Delta Factory Service Centers and Delta Authorized Service Stations. T o obtain additional information regar ding your Delta quality product or to obtain parts, service, warra ...

  • Porter-Cable 70-200 - page 21

    The following are trademarks of POR TER-CABLE • DEL T A (Las siguientes son marcas registradas de POR TER-CABLE • DEL T A S.A.) (Les marques suivantes sont des marques de fabriquant de la POR TER-CABLE • DEL T A): Auto-Set ® , BAMMER ® , B.O.S.S. ® , Builder’ s Saw ® , Contractor’ s Saw ® , Contractor’ s Saw II™, Delta ® , DEL T ...

メーカー Porter-Cable カテゴリー Drill

Porter-Cable 70-200のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 70-200の取扱説明書
- Porter-Cableの製品カード
- パンフレット
- またはPorter-Cable 70-200の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Porter-Cable 70-200の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Porter-Cable 70-200の取り付け説明書、サービスマニュアル、簡易説明書、またはPorter-Cable 70-200のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Porter-Cable 70-200の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Porter-Cable 70-200デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがPorter-Cable 70-200を使用するのを助ける技術的文書のことです。説明書は通常、全てのPorter-Cable 70-200ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Porter-Cableの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Porter-Cable 70-200の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははPorter-Cable 70-200の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Porter-Cable 70-200に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Porter-Cable 70-200デバイスの基本機能を使うにあたってのヒント。 Porter-Cable 70-200のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Porter-Cable 70-200に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるPorter-Cable 70-200のメーカー/サービスへの連絡先に関する情報。

Porter-Cable 70-200についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもPorter-Cable 70-200の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがPorter-Cable 70-200で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)