    CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com • E-mail: info@blackbox.com DECEMBER ...

  • Black Box IC107C-R3 - page 2

    1 FCC/IC RFI ST A TEMENTS, DECLARA TION OF CONFORMITY FEDERAL COMMUNICA TIONS COMMISSION AND INDUSTR Y CANADA RADIO-FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interf ...

  • Black Box IC107C-R3 - page 3

    2 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY ST A TEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia fu ...

  • Black Box IC107C-R3 - page 4

    3 NOM ST A TEMENT , TRADEMARKS 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptá ...

  • Black Box IC107C-R3 - page 5

    4 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Contents Chapter Page 1. Specifications ............................................................................................. 5 2. Introduction ............................................................................................... 7 3. Configuration ................................. ...

  • Black Box IC107C-R3 - page 6

    5 CHAPTER 1: Specifications 1. Specifications Compliance: CE; FCC Part 15 Subpart B Class A, IC Class/classe A Interfaces: EIA/TIA RS-232, DTE or DCE (user-selectable); EIA/TIA RS-422/485 Protocol: Asynchronous Data Rate: Transparent to data rates up to 64 kbps Data Format: Transparent to data format Flow Control: Transparent to software flow contr ...

  • Black Box IC107C-R3 - page 7

    6 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Temperature Tolerance: Operating: 32 to 122˚F (0 to 50˚C) Storage: –4 to +158˚F (–20 to +70˚C) Humidity Tolerance: Up to 95% noncondensing MTBF: 200,000 hours Power: IC107A-R3 and IC107AE-R3: From utility-power (mains) outlet, through external power supply with detachable region-specific inp ...

  • Black Box IC107C-R3 - page 8

    7 CHAPTER 2: Introduction 2. Introduction The RS-232 ↔ RS-422/485 Converter (Data Only) allows your RS-232 and RS-422/485 equipment to communicate with each other. It operates in full-duplex mode over 4-wire lines. A four-wire terminal block on the RS-422/485 port makes installation easy. And this interface converter is flexible: it can work in e ...

  • Black Box IC107C-R3 - page 9

    8 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 3. Configuration Here’s how to configure the RS-232 ↔ RS-422/485 Converter (Data Only) for your application (refer to Figure 3-1 on the next page for the location of components on the circuit board): CAUTION! The Converter’s circuit board can be damaged by static electricity, so take every rea ...

  • Black Box IC107C-R3 - page 10

    9 CHAPTER 3: Configuration 5. Normally, the Converter’s frame ground is isolated from its RS-232 signal ground. But if you want to connect frame ground to signal ground, you’ll need to solder a 100-ohm, 500-mW resistor to the terminals of location W7. (You could also use a wire jumper, but you’d need to make sure that any ground-loop currents ...

  • Black Box IC107C-R3 - page 11

    10 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 4. Installation To install your RS-232 ↔ RS-422/485 Converter (Data Only) system, take these steps, making sure that the Converter and your devices are powered OFF: 1. Run an RS-232 cable from your RS-232 device to the Converter’s DB25 female RS-232 port. 2. Run a 4-wire cable from your RS-422 ...

  • Black Box IC107C-R3 - page 12

    11 CHAPTER 5: Operation 5. Operation 5.1 RS-232 Circuitry The RS-232 side of the RS-232 ↔ RS-422/485 Converter (Data Only) is composed of the RS-232 drivers and receivers, the delay circuitry, and other circuitry necessary to operate the RS-232 control lines. Data traveling from the RS-232 interface to the RS-422/485 interface: When the RS-232 po ...

  • Black Box IC107C-R3 - page 13

    12 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) Figure 5-1. Block diagram of Converter functions in DCE mode. Figure 5-2. Block diagram of Converter functions in DTE mode. RS-232 side RS-232 side RS-422/485 side RS-422/485 side ...

  • Black Box IC107C-R3 - page 14

    13 CHAPTER 5: Operation 5.2 RS-422/485 Circuitry The RS-422/485 side of the Converter is made up of the driver, receiver, and line- termination networks. As described in Chapter 3 , you can use switch S2 to either connect the receiver’s termination network to the line (terminate the RS-422/485 port) or leave it unconnected (unterminated). Having ...

  • Black Box IC107C-R3 - page 15

    14 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) 6. T roubleshooting 6.1 Calling Black Box If you determine that your RS-232 ↔ RS-422/485 Converter (Data Only) is malfunctioning, do not attempt to alter or repair the unit . It has no user-serviceable components. Contact Black Box Technical Support at 724-746-5500. Before you do, make a record o ...

  • Black Box IC107C-R3 - page 16

    15 APPENDIX: Pinouts Appendix: Pinouts T able A-1. Pinning of the RS-232 connector (DB25 female). Pin Number and Signal Function Pin1 — Frame Ground Connects the Converter’s frame ground to the frame ground of the RS-232 device. Pin 2 — TD When the Converter is set to DCE, data is received on Pin 2 and the TX LED lights up when Pin 2 is a “ ...

  • Black Box IC107C-R3 - page 17

    16 RS-232 ↔ RS-422/485 CONVER TER (DA T A ONL Y) T able A-2. Pinning of the RS-422/485 connector (4-position ter minal block). Pin/Signal Function TXA and TXB Data received by the Converter from the RS-232 port is transmitted out of the unit over twisted-pair wires using these two outputs. The “TX” LED indicates the state of these two leads. ...

  • Black Box IC107C-R3 - page 18

    NOTES ...

  • Black Box IC107C-R3 - page 19

    NOTES ...

  • Black Box IC107C-R3 - page 20

    1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 2001. Black Box Corporation. All rights reserved. ...

メーカー Black Box カテゴリー Cable Box

Black Box IC107C-R3のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IC107C-R3の取扱説明書
- Black Boxの製品カード
- パンフレット
- またはBlack Box IC107C-R3の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Black Box IC107C-R3の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Black Box IC107C-R3の取り付け説明書、サービスマニュアル、簡易説明書、またはBlack Box IC107C-R3のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Black Box IC107C-R3の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Black Box IC107C-R3デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBlack Box IC107C-R3を使用するのを助ける技術的文書のことです。説明書は通常、全てのBlack Box IC107C-R3ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Black Boxの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Black Box IC107C-R3の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBlack Box IC107C-R3の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Black Box IC107C-R3に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Black Box IC107C-R3デバイスの基本機能を使うにあたってのヒント。 Black Box IC107C-R3のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Black Box IC107C-R3に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBlack Box IC107C-R3のメーカー/サービスへの連絡先に関する情報。

Black Box IC107C-R3についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBlack Box IC107C-R3の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBlack Box IC107C-R3で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)