Graco 307212ZACの取扱説明書

24ページ 0.33 mb
ダウンロード

ページに移動 of 24

Summary
  • Graco 307212ZAC - page 1

    ST AINLESS STEEL, W A TERBASE COMP A TIBLE Fluid Pressure Regulators Used to regulate fluid pressure in low pressure systems only . Fluid Flow up to 3 GPM (1 1 liters/min) Instructions–Parts List 307212ZAC EN Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. See page 2 for T able of Contents ...

  • Graco 307212ZAC - page 2

    2 307212 T able of Contents Models 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 307212ZAC - page 3

    3 307212 Models Spring Operated Fluid Regulators Part No. Series Maximum Fluid Inlet Pressure, psi (kPa, bar) Regulated Pressure Range, psi (kPa, bar) Gauge Gauge Pressure Range, psi (kPa, bar) 214895 H 250 (1800, 18) 5–100 (34–700, 0.3–7) No n/a 214706  H 250 (1800, 18) 5–100 (34–700, 0.3–7) Y es (see 0–100 (0–700, 0–7) below) ...

  • Graco 307212ZAC - page 4

    4 307212 Notes ...

  • Graco 307212ZAC - page 5

    5 307212 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury .  Do not stop or deflect fluid leaks with your hand, body , glove, or rag.  Follow the Pressure Relief Procedure on page 8 whenever you: are instructed to relieve the press ...

  • Graco 307212ZAC - page 6

    6 307212 Installation FLUID SUPPL Y INLET BALL V A L VE OUTLET BALL V A L VE PIPE NIPPLES BACK PRESSURE VA LV E FLUID RETURN AIR FIL T ER & REGULA TOR Spring Operated Installation Models 214895, 214706, 217314, 221 1 18, 255374, and 24A082 Pilot Regulator Air Supply Line Air Operated Installation Model 214980 shown OUTLET BALL V A L VE AIR SUPP ...

  • Graco 307212ZAC - page 7

    7 307212 Installation Fluid pressure regulators are used for accurate, posi- tive control of the fluid pressure to spray guns, dis- pensing valves or atomizing heads. Regulators installed at circulating line take-offs or pumps are used to reduce main line pressure and maintain the desired fluid pressure to the spray gun or atomizing head. Before In ...

  • Graco 307212ZAC - page 8

    8 307212 Operation CAUTION  The new system must be cleaned and tested thoroughly before admitting fluid to the regulator to avoid contaminants clogging or damaging the regulator .  Always use the lowest possible air and fluid pressures for your application. High pressures cause premature spray nozzle and pump wear . NOTE: Reference numbers an ...

  • Graco 307212ZAC - page 9

    9 307212 Operation 7. Adjust the fluid regulator to the desired setting. a. Spring Operated Regulators Only (see Fig. 3). The regulator can be adjusted in two ways:  Using the male end (B) of the regulator key (24), turn the socket–head adjustment screw (19) fully clockwise . V erify that the pressure setting has not changed.  Using the fem ...

  • Graco 307212ZAC - page 10

    10 307212 Notes ...

  • Graco 307212ZAC - page 11

    11 307212 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Before servicing this equipment always make sure to Relieve the Pressure . Check all possible remedies in the T roubleshooting Chart before disassembling the fluid regulato ...

  • Graco 307212ZAC - page 12

    12 307212 Service Service of the Air Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s air inlet. Refer to Fig. 2. 3. Release all the air and fluid pressure in ...

  • Graco 307212ZAC - page 13

    13 307212 Service Models 214980 (shown) & 244375 29 10 13 23 7 1 17 22 26 18 9 15 16 4 20 40 6 21 3 NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N  m), then retorque to 125 in-lb (14 N  m) three times, consecu- tively , to compensate for diaphragm relaxation. 5 2 4 6 1 3 BOTTOM VIEW Air Bleed Hole ...

  • Graco 307212ZAC - page 14

    14 307212 Service Service of the Spring Operated Regulators W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. 1. Shut off the pump. 2. Close the ball valve at the regulator ’ s fluid inlet. See Fig. 1. 3. Release all fluid pressure in the regulato ...

  • Graco 307212ZAC - page 15

    15 307212 Service 10 Models 217314 and 221 1 18 Models 214895, 214706, 255374, and 24A082 21 12 13 22 25 17 26 3 15 16 23 40 6 9 18 4 20 1 7 10 21 12 13 22 17 26 3 15 16 23 40 6 9 18 4 20 1 5 2 4 6 1 3 BOTTOM VIEW PET NOTE: Numbers indicate tightening sequence. T ighten evenly to 7–10 in-lb (0.8–1.1 N  m), then retorque to 125 in-lb (14 N ? ...

  • Graco 307212ZAC - page 16

    16 307212 Parts 24 7 19 14 12 11 5 10  *21  *3  *9 27 28 23 4*   *15  *16  *20 40*  1 6 18 26*  22*  17 13 Model 214895, Series H Without gauge. Includes items 1–26, 40 Model 214706, Series H With gauge. Includes items 1–40 Model 214706 only Ref No. Part No. Descri ption Qty . Ref. No. Part No. Descri ption Qty . 1 ...

  • Graco 307212ZAC - page 17

    17 307212 Parts 24 7 19 14 12 11 5 10  *21  *3  *9 27 23 4*   *15  *16  *20 40*  1 6 18 26*  22*  17 13 TI0037 Model 255374, Series A Model 24A082, Series A ISO pitch thread inlet and outlet (n ot compatible with US standard pitch – fluid housing coated with PTFE based polymer) Includes items 1–40 Ref No. Part No. ...

  • Graco 307212ZAC - page 18

    18 307212 Parts 24 7 19 14 12 11 5 10  *21  *3  *9 27 28 23 4*   *15  *16  *20 40*  1 6 32 18 26*  25*  17 13 Model 221 1 18 only Model 217314, Series F With gauge. Includes items 1–32, 40 Model 221 1 18, Series E Without gauge. Includes items 1–26, 32–40 22*  39 Model 217314 only Ref No. Part No. Descri ption ...

  • Graco 307212ZAC - page 19

    19 307212 Parts Model 214980 Series F Includes items 1–40  *9 7 29 10  *21  *3 27 28  *15  *16  *20 40*  4*  23 1 18 26*  22*  17 13 6 Ref No. Part No. Description Qty . Ref. No. Part No. Description Qty . 1 100644 SCREW , soc hd cap; 0.25”–20 x 0.75” 6 3 1 1 1736*  SPRING, compression 1 4 104319*  O-RING ...

  • Graco 307212ZAC - page 20

    20 307212 Parts TI1697A Model 244375 Series B Includes items 1–41  *9 7 10  *21  *3  *15  *16  *20 40*  4*  23 1 18 26*   *22 13 6 29 17 19 41 Ref No. Part No. Description Qty . Ref. No. Part No. Descri ption Qty . 1 100644 SCREW , soc hd cap; 0.25”–20 x 0.75” 4 3 1 1 1736*  SPRING, compression 1 4 104319* ? ...

  • Graco 307212ZAC - page 21

    21 307212 Dimensions Model 244375: 3” (76.2 mm) All Other Models: 4.94” (125.5 mm) 1.76” (44.7 mm) 1.8” (46 mm) 3/8 npsm female INLET 3.65” (93 mm) DIA. 3/8 npt(f) OUTLET 1/4 npt GAUGE PORT 10.25” (260 mm) 1/4 npt AIR INLET (Model 214980 only) 3/8 npsm female ADAPTER OUTLET (Models 217314 and 221 1 18 only) ...

  • Graco 307212ZAC - page 22

    22 307212 T echnical Data Category Data Maximum Fluid Inlet Pressure 250 psi (1.8 MPa, 18 bar) Regulated Fluid Pressure Range Models 217314 & 221 1 18: 20–160 psi (0.15–1.1 MPa, 1.5–1 1 bar) Models 214706, 214895, 244375, 255374, & 24A082: 5–100 psi (30–700 kPa, 0.3–7.0 bar) Model 214980: 0–30 psi (0–210 kPa, 0–2 bar) Maxi ...

  • Graco 307212ZAC - page 23

    23 307212 Performance Chart 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 0123 45 FLUID FLOW kPa bar p si gpm liters/min 0 10 20 30 40 50 60 70 80 90 100 0123 45 3.82 7.62 1 1.42 15.22 22.10 liters/min 3.82 7.62 1 1.42 15.22 22.10 gpm FLUID FLOW MODELS 217314 and 221 1 18 MODELS 214706, 214895, 214980, 244375, 255374, and 24A082 kPa bar ...

  • Graco 307212ZAC - page 24

    24 307212 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months from th ...

メーカー Graco カテゴリー Scuba Diving Equipment

Graco 307212ZACのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 307212ZACの取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 307212ZACの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 307212ZACの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 307212ZACの取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 307212ZACのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 307212ZACの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 307212ZACデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 307212ZACを使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 307212ZACユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 307212ZACの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 307212ZACの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 307212ZACに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 307212ZACデバイスの基本機能を使うにあたってのヒント。 Graco 307212ZACのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 307212ZACに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 307212ZACのメーカー/サービスへの連絡先に関する情報。

Graco 307212ZACについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 307212ZACの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 307212ZACで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)