Johnson Controls BQ 048の取扱説明書

40ページ 1.26 mb
ダウンロード

ページに移動 of 40

Summary
  • Johnson Controls BQ 048 - page 1

    INST ALLA TION MANUAL CAUTION: READ ALL SAFETY GUIDES BEFORE YOU BEGIN TO INST ALL YOUR UNIT . SAVE THIS MANUAL ISO 9001 Certified Quality Management System SUNLINE 2000™ SINGLE P ACKAGE HEA T PUMP BQ 036, 048 & 060 EXPORT ONLY 364985-XIM-B-0508 CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 SAFETY CONSIDER ...

  • Johnson Controls BQ 048 - page 2

    364985-XIM-B-0508 2 Johnson Controls Unitary Products T ABLE OF CONTENTS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 SAFETY CONSIDERATION S . . . . . . . . . . . . . . . . . . 4 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Johnson Controls BQ 048 - page 3

    364985-XIM-B-0508 Johnson Controls Unitary Products 3 LIST OF FIGURES Fig. # Pg. # 1 RECOMMENDED DRAIN PIPING . . . . . . . . . . . . . . . . 7 2 COMPRESSOR RESTRAINING BRACKET . . . . . . . . 8 3 TYPICAL FIELD POWER & CONTROL WIRING . . . . 9 4 ENTHALPY SETP OINT ADJUSTMENT . . . . . . . . . . 13 5 HONEYWELL ECONOMIZER CONTRO L W7212 . . . 13 ...

  • Johnson Controls BQ 048 - page 4

    364985-XIM-B-0508 4 Johnson Controls Unitary Products GENERAL YORK Model BQ units are single package heat pumps equipped wit h optional factor y installed electric h eat- ers. These are designe d for outdoor installation o n a rooftop or slab . The units are complete ly assembled on ri gid, perma- nently attached base r ails. All piping, refrigeran ...

  • Johnson Controls BQ 048 - page 5

    364985-XIM-B-0508 Johnson Controls Unitary Products 5 PRODUCT NOMENCLA TURE B Q 048 N04 A 2 A AA 1 0 1 2 4 A Product Category B = HP, Single Pkg., R-22 A = Direct Drive Airflow B = Direct Drive/Single Input Economizer D = Direct Drive/Motorized Damper N = Belt Drive P = Belt Drive/Single Input Economizer R = Belt Drive/Motorized Damper T = Belt Dri ...

  • Johnson Controls BQ 048 - page 6

    364985-XIM-B-0508 6 Johnson Controls Unitary Products INST ALLA TION INST ALLA TION SAFETY INFORMA TION: Read these in structions befo re continuing this appli- ance installation. This is an outdoor combination hea t- ing and cooling unit. The installer must assure that these instructions are ma de available to th e consumer and with instructions t ...

  • Johnson Controls BQ 048 - page 7

    364985-XIM-B-0508 Johnson Controls Unitary Products 7 RIGGING AND HANDLING Exercise care when mo ving the unit. Do not r emove any packaging until the unit is near th e place of installa- tion. Rig the unit by attaching chain or cable slings to the lifting ho les provided in the base rails. Spreader bars, whose length exceeds the largest dimension ...

  • Johnson Controls BQ 048 - page 8

    364985-XIM-B-0508 8 Johnson Controls Unitary Products COMPRESSORS Units are shipped with comp ressor mountings factory- adjusted and ready for ope ratio n. Units with scroll co mpressors have a shipping bracket which must be removed after th e unit is set in place. See Figure 2. FIL TERS One-inch or two-inch filters ca n be supplied with each unit. ...

  • Johnson Controls BQ 048 - page 9

    364985-XIM-B-0508 Johnson Controls Unitary Products 9 FIGURE 3 - TYPICAL FIELD POWER & CONTROL WIRING REFER T O THE ELECTRICAL D A T A T ABLES TO SIZE THE DISCONNECT SWITCH, O VERCURRENT PRO TEC- TION AND WIRING. RC RH Y1 Y2 W1 W2 G LED 1 LED 2 COM A1 A2 T T B R Y1 Y2 G C X OCC W2 W1 THERMOSTAT 1 TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSF ...

  • Johnson Controls BQ 048 - page 10

    364985-XIM-B-0508 10 Johnson Controls Unitary Products THERMOST A T The room thermosta t should be located on an inside wall approximat ely 56 inches above the floor where it will not be subject to drafts, sun exposure or heat from electrical fixtures or appliances. Fo llow the manufac- turer's instruc tions enclosed with the thermos tat for g ...

  • Johnson Controls BQ 048 - page 11

    364985-XIM-B-0508 Johnson Controls Unitary Products 11 ECONOMIZER/MOTORIZED DAMPER AND RAIN HOOD The instruction for the optiona l economizer/motorized damper and rain hood can be fo und in form 035- 07364-000. Use these instructions when field assem- bling an economizer rain hood onto a unit. The outdoo r and return air dampers, the da mper actuat ...

  • Johnson Controls BQ 048 - page 12

    364985-XIM-B-0508 12 Johnson Controls Unitary Products MINIMUM POSITION ADJUSTMENT With thermostat set to indoor fan on positio n, or termi- nals “R” to “G” energized, turn the M inimum Position Adjusting screw (located o n the damper control mod - ule) counterclockwise until the de sired minimum damper position has be en attained. ENTHALPY ...

  • Johnson Controls BQ 048 - page 13

    364985-XIM-B-0508 Johnson Controls Unitary Products 13 FIGURE 4 - ENTHALPY SETPOINT ADJUSTMENT 40 (4) 70 (21) 50 (10) 55 (13) 60 (16) 65 (18) 35 (2) 45 (7) 75 (24) 80 (27) 35 (2) 40 (4) 45 (7) 50 (10) 55 (13) 60 (16) 65 (18) 70 (21) 75 (24) 80 (27) 85 (29) 85 (29) 90 (32) 90 (32) 105 (41) 110 (43) 100 (38) 95 (35) 95 (35) 100 (38) 105 (41) 110 (43) ...

  • Johnson Controls BQ 048 - page 14

    364985-XIM-B-0508 14 Johnson Controls Unitary Products FIGURE 6 - FOUR AND SIX POINT LOADING 44 7 / 8 82 1 / 4 Y X A B C D CONDENSER COIL END OF UNIT FRONT OF UNIT APPROXIMATE CENTER OF GRAVITY BACK OF UNIT 44 7 / 8 82 1 / 4 Y X A B C D E F CONDENSER COIL END OF UNIT FRONT OF UNIT APPROXIMATE CENTER OF GRAVITY BACK OF UNIT T ABLE 4: CENTER OF G RA ...

  • Johnson Controls BQ 048 - page 15

    364985-XIM-B-0508 Johnson Controls Unitary Products 15 T ABLE 7: PHYSICAL DATA MODELS BQ 036 048 060 EV APORA TOR BLOWER Centrifug al Blower (Dia. x Wd. in.) 12 X 10 12 X 10 12 X 10 Fan Motor HP (Dire c t Dri ve ) 1/2 3/4 1 Fan Motor HP (Bel t Drive) 1 1/2 1 1/2 1 1/2 Fan Motor HP (Bel t Drive High Static) 1 1/2 1 1/2 2 EV APORA TOR COIL Rows Deep ...

  • Johnson Controls BQ 048 - page 16

    364985-XIM-B-0508 16 Johnson Controls Unitary Products T ABLE 9: ELECTR ICAL DA T A - BQ036-060 DI RECT DRIVE W/O POWERED CONV ENIENCE OUTLET Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Pwr Conv Outlet Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps ) 2. Dual Element, ...

  • Johnson Controls BQ 048 - page 17

    364985-XIM-B-0508 Johnson Controls Unitary Products 17 T ABLE 10: ELECTRICAL DA T A - BQ036-060 BE L T DRIVE W/O POWERED CON VENIE NCE OUTLET Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Pwr Conv Outlet Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps ) 2. Dual Element, ...

  • Johnson Controls BQ 048 - page 18

    364985-XIM-B-0508 18 Johnson Controls Unitary Products T ABLE 1 1: ELECTRICAL DA T A - BQ036-060 BEL T DR IVE HIGH ST A TIC W/O POWERED CONVENIENCE OUTLET Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Pwr Conv Outlet Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps ) 2. ...

  • Johnson Controls BQ 048 - page 19

    364985-XIM-B-0508 Johnson Controls Unitary Products 19 T ABLE 12: ELECTRICAL DA T A - BQ036-060 DI RECT DRIVE W/POWERED CONVEN IENCE OUTLET Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Pwr Conv Outlet Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps ) 2. Dual Element, T ...

  • Johnson Controls BQ 048 - page 20

    364985-XIM-B-0508 20 Johnson Controls Unitary Products T ABLE 13: ELECTRICAL DA T A - BQ036-06 0 BELT DRIVE W /POWERED CONVENIENCE OUTLET Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Pwr Conv Outlet Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps ) 2. Dual Element, Tim ...

  • Johnson Controls BQ 048 - page 21

    364985-XIM-B-0508 Johnson Controls Unitary Products 21 T ABLE 14: ELECTRICAL DA T A - BQ036-060 BELT DRIVE HIGH ST A TIC W/POWERED CONVENIENCE OUTLET Size (Tons) Volt Compressors (each) OD Fan Motors (each) Supply Blower Motor Pwr Conv Outlet Electric Heat Option MCA 1 (Amps) 1. Minimum Circuit Ampacity. Max Fuse 2 / Breaker 3 Size (Amps ) 2. Dual ...

  • Johnson Controls BQ 048 - page 22

    364985-XIM-B-0508 22 Johnson Controls Unitary Products T ABLE 15: ELECTRIC HEA T CORRECTION FA C T O R S NOMINAL VOL T AGE VOL T AGE kW CAP . MUL TIPLIER 208 208 0.75 240 230 0.92 480 460 0.92 600 575 0.92 T ABLE 16: VOL T AGE LIMIT A TIONS 1 1. Utilization Range “A” in accordance with ARI S tandard 1 10. POWER SUPPL Y V O LTA G E MIN. MAX. 208 ...

  • Johnson Controls BQ 048 - page 23

    364985-XIM-B-0508 Johnson Controls Unitary Products 23 FIGURE 8 - UNIT WITH ECO NOMIZER RAINHOOD FIGURE 9 - UNIT WITH FIXED OU TDOOR AIR/MOTORIZED DAMPER RAINHOOD DETAIL “A” DETAIL “B” ...

  • Johnson Controls BQ 048 - page 24

    364985-XIM-B-0508 24 Johnson Controls Unitary Products FIGURE 10 - UNIT DIMENSION S (REAR VIEW) FIGURE 1 1 - DISC ONNECT/BLOWER ACCESS LOCA TION T ABLE 17: UTILITIES ENTRY HOLE OPENING SIZE (DIA.) USED FOR A 7/8” KO 1 Contro l Wiring 2 Side Bottom B 2” KO 1 Power W iring Side Bottom C 1-5/8” KO Gas Piping (Fr ont ) D 1-1/2” KO Gas Piping ( ...

  • Johnson Controls BQ 048 - page 25

    364985-XIM-B-0508 Johnson Controls Unitary Products 25 T ABLE 19: SUPPL Y AIR BLOW ER PERFORMANCE (BQ036 BEL T DRIVE) - SIDE DUCT APPLICA TION Air Flow (CFM) Available External Static Pressure - IWG 1 1. Blower performance includes 1” fi lters. See STATIC RESISTANCE table for additional applications. 2. See RPM SELECTION table to determine desire ...

  • Johnson Controls BQ 048 - page 26

    364985-XIM-B-0508 26 Johnson Controls Unitary Products T ABLE 23: SUPPL Y AIR BLOW ER PERFORMANCE (BQ060 BEL T DRIVE) - SIDE DUCT APPLICA TION Air Flow (CFM) Available External Static Pressure - IWG 1 1. Blower performance includes 1” filters. See STAT IC RESISTANCE table for add itional applications. 2. See RPM SELECTION table to determine desir ...

  • Johnson Controls BQ 048 - page 27

    364985-XIM-B-0508 Johnson Controls Unitary Products 27 T ABLE 26: SUPPLY AIR BLOWER PERFORMANCE (BQ036, 048 & 060 DIRECT DRIVE) - BOTTOM DUCT APPLICATION UNIT TONNAGE MOT OR 1 SPEED A V AILABLE EXTERNAL ST A TIC PRESSURE - IWG 2 0.2 0.3 0.4 0. 5 0.6 0.7 0.8 0 .9 1.0 CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A ...

  • Johnson Controls BQ 048 - page 28

    364985-XIM-B-0508 28 Johnson Controls Unitary Products Drive Selection 1. Determ ine d esired airflow. 2. Calculate or measure the amount of external static pressure. 3. Using the opera ting point determined from steps 1 & 2, locate this po int on the appropriate supply air blower performance tab le. (Linear interpolation may be necessary.) 4. ...

  • Johnson Controls BQ 048 - page 29

    364985-XIM-B-0508 Johnson Controls Unitary Products 29 Altitude/Tempe rature Correction Fa ctors Air Temp. Altitude ( Ft.) 0 1000 2000 3000 4000 5000 6000 700 0 8000 9000 10000 40 1.060 1.022 0.986 0.950 0.916 0.882 0.849 0.818 0.788 0.758 0.729 50 1.039 1.002 0.966 0.931 0.898 0.864 0.832 0.802 0.772 0.743 0.715 60 1.019 0.982 0.948 0.913 0.880 0. ...

  • Johnson Controls BQ 048 - page 30

    364985-XIM-B-0508 30 Johnson Controls Unitary Products PHASING Check for proper compressor rotation. If the blower or compressors rotate in the wrong direction at start-up, the electrical con nection to the unit is mi sphased. Change the incoming line con nection phasing to ob tain proper rotation. (Scroll compre ssors operate in only one direction ...

  • Johnson Controls BQ 048 - page 31

    364985-XIM-B-0508 Johnson Controls Unitary Products 31 under field conditions would be inaccurate. T o assure a dry coil, the compressors should be deac- tivated while the test is being run. 4. Knowing the pre ssure drop across a dr y coil, the actual CFM through the unit can be determine d from the curve in Pressure Drop vs. Su pply Air CFM (Figur ...

  • Johnson Controls BQ 048 - page 32

    364985-XIM-B-0508 32 Johnson Controls Unitary Products ECONOMIZER WITH SING LE ENTHALPY SENSOR - When the room thermostat calls for coo ling, the low voltage control circuit from “R” to “G” and “Y1” is com- pleted. The UCB energizes t he blowe r motor (if the fan switch on the room thermost at is set in the “AUTO” position) and driv ...

  • Johnson Controls BQ 048 - page 33

    364985-XIM-B-0508 Johnson Controls Unitary Products 33 ing is still pr esent at th e conclusion o f the ASCD, the UCB will re-energize the compressor. Should a freezestat op en three times within two hours of operation, the UCB will lo ck-out the compressor and flash a code (see Table 32). LOW AMBIENT COOLING To determine when to op erate in low am ...

  • Johnson Controls BQ 048 - page 34

    364985-XIM-B-0508 34 Johnson Controls Unitary Products DEFROST MODE As mentioned earlier, the de frost control (DC) utilizes a time/temperature defrost scheme. The following two conditions must be met before the DC will enter a defrost mo de: The defros t thermostat (SD) mu st be closed. T his nor- mally open thermostat is mo unte d on the liq uid ...

  • Johnson Controls BQ 048 - page 35

    364985-XIM-B-0508 Johnson Controls Unitary Products 35 Refer to Table 31 for the required electric he at anticipa- tor setting. ST ART -UP (COOLING) PREST ART CHECK LIST After installation has been completed: 1. Check the electrical supply volt age being supplied. Be sure that it is th e same as listed on the unit nameplate. 2. Set the room thermos ...

  • Johnson Controls BQ 048 - page 36

    364985-XIM-B-0508 36 Johnson Controls Unitary Products has energized when the fan switch is in the AUT O position, check the room thermostat fo r contact between R and G in the AUTO position during calls for cooling. 3. If the supply air blower motor do es not energize when the fan switch is set to ON, check that line voltage is b eing supplied to ...

  • Johnson Controls BQ 048 - page 37

    364985-XIM-B-0508 Johnson Controls Unitary Products 37 The UCB will flash the last five alarms on th e LED. If the compressor is locked out, cancel any call for cool- ing. This will reset any compressor lock outs. NOTE: W hile the above step will reset any lockouts, the compressor may be held of f for the ASCD. See the next step. 10. If 24 volts is ...

  • Johnson Controls BQ 048 - page 38

    364985-XIM-B-0508 38 Johnson Controls Unitary Products MAINTENANCE NORMAL MAINTENANCE FIL TERS Inspect once a month. Replace dispo sable or clean permanen t type as n ecessary. DO NOT replac e per- manent type with disposable. The dimension al size of the replacement filter m ust be the same as the replaced filter. MOTORS Outdoor fan motors are per ...

  • Johnson Controls BQ 048 - page 39

    364985-XIM-B-0508 Johnson Controls Unitary Products 39 ...

  • Johnson Controls BQ 048 - page 40

    Subject to change without notice. Print ed in U.S.A. 364985-XIM-B-0508 Copyright © 2008 by Johnson Controls, In c. All righ ts reserved. Supersedes: 364985-YIM-A -0308 Johnson Controls Un itary Products 5005 York Drive Norman, OK 73069 ...

メーカー Johnson Controls カテゴリー Heat Pump

Johnson Controls BQ 048のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BQ 048の取扱説明書
- Johnson Controlsの製品カード
- パンフレット
- またはJohnson Controls BQ 048の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Johnson Controls BQ 048の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Johnson Controls BQ 048の取り付け説明書、サービスマニュアル、簡易説明書、またはJohnson Controls BQ 048のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Johnson Controls BQ 048の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Johnson Controls BQ 048デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがJohnson Controls BQ 048を使用するのを助ける技術的文書のことです。説明書は通常、全てのJohnson Controls BQ 048ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Johnson Controlsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Johnson Controls BQ 048の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははJohnson Controls BQ 048の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Johnson Controls BQ 048に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Johnson Controls BQ 048デバイスの基本機能を使うにあたってのヒント。 Johnson Controls BQ 048のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Johnson Controls BQ 048に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるJohnson Controls BQ 048のメーカー/サービスへの連絡先に関する情報。

Johnson Controls BQ 048についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもJohnson Controls BQ 048の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがJohnson Controls BQ 048で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)