    1 PRINTED IN THE U.S.A. 0406 P ART NO. 197086-000 Thank you for buying this energy efficient water heater . We appreciate your confidence in our product s. Y ou should thoroughly read this manual before installation and/ or operation of this water heater . Please pay particular attention to the important safety and operating instructions as well as ...

  • A.O. Smith BTX-80 - page 2

    2 ROUGH-IN-DIMENSIONS Rough-In-Dimensions Model Units A B C D E F G H J K Inches 70.62 68.20 51. 90 20.90 9.15 12.00 22. 00 8.00 15.81 26. 92 BTX -80 cm 179.37 173.23 131 .83 53. 09 23.24 30.48 55. 88 20.32 40.16 68.38 T op/Side Inlet and Outlet: 3/4" NPT Gas Inlet: 1/2" NPT Capacity and Gas and Electrical Characteristics A ppr oximate Ca ...

  • A.O. Smith BTX-80 - page 3

    3 * CAUTION HARNESS HAS 120 V AC. IN OPERA TION. ** See "PLANNING THE VENT SYSTEM", "CONDENSA TE" and "PREPA RA TION OF BLOWER ASSEMBL Y" in the "INST ALLA TION" section for more information. ** * The side recirculation loop connections may not be used as the primary water inlet and outlet connections. For yo ...

  • A.O. Smith BTX-80 - page 4

    4 GENERAL SAFETY INFORMA TION EXTERNAL DAMAGE Do not operate the water heater until it has been fully checked out by a qualified technician, if the water heater: • Has been exposed to fire or damage. • Displays evidence of sooting. • Produces steam or unusually hot water . If the water heater has been subject to flooding it must be replaced. ...

  • A.O. Smith BTX-80 - page 5

    5 • Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference. • Do obtain new warning and instruction labels for placement on the blanket directly over the existing labels. • Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow ...

  • A.O. Smith BTX-80 - page 6

    6 If the unconfined space is within a building of tight construction (building using the following construction: weather stripping, heavy insulation, caulking, vapor barrier , etc.), air for combustion and ventilation must be obtained from out doors. The installation instructions for confined spaces must be followed. CONFINED SP ACE When drawing co ...

  • A.O. Smith BTX-80 - page 7

    7 REFER TO FIG . 1 FOR CONNECTION DET AILS. BEFORE A T T ACHING THE GAS LINE BE SURE THA T ALL GAS PIPE IS CLEAN ON THE INSIDE. T O TRAP A NY DIRT OR FOREIGN MA TERIAL IN THE GAS SUPPL Y LINE, A DIRT LEG (SOMETIMES CALLED DRIP LEG) MUST BE INCORPORA TED IN THE PIPING , FIGURE 1. The dirt leg must be readily accessible. Inst all in accordance with r ...

  • A.O. Smith BTX-80 - page 8

    8 combustible materials must be provided in accordance with information in this manual under LOCA TION OF HEATER and INST ALLA TION OF VENT SYSTEM, and with the National Fuel Gas Code and local codes. PLANNING THE VENT SYSTEM Plan the route of the vent system from the discharge of the blower to the planned location of the vent terminal. 1. Layout t ...

  • A.O. Smith BTX-80 - page 9

    9 an incorporated reservoir may be used to pump the water to an appropriate drain. T o avoid condensate spillage, select a pump with an overflow switch. CAUTION MUST BE USED TO ENSURE TH A T THE DRAIN IS FREE AND CLEAR OF DEBRIS AND WILL NOT ALLOW BACKFLOW THROUGH THE CONDENSA TE HOSE. CONSIDERA TION MUST BE GIVEN TO A VOID FREEZING OF THE CONDENSA ...

  • A.O. Smith BTX-80 - page 10

    10 W ARNING CONDENSA TE ALSO DRAINS FROM TWO LOCA TIONS ON THE BLOWER ASSEMBL Y AS SHOWN IN FIGURE 5. A CONDENSA TE HOSE MUST BE SECURED TO FORM A "TRAP" AS SHOWN IN FIGURE 5 FOR THESE CONDENSA TE DRAIN CONNECTIONS. THESE TWO HOSES MA Y BE CONNECTED TOGETHER. THE HOSE(S) SHOULD BE ROUTED T O A SUIT ABLE DRAIN. A fitting that may be used t ...

  • A.O. Smith BTX-80 - page 11

    11 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SER VICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA TION. VERIFY PROPER OPERA TION AFTER SER VICING . POWER VENT WIRING SCHEMA TIC - FIGURE 7 ...

  • A.O. Smith BTX-80 - page 12

    12 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as discussed in the section of this manual titled PLANNING THE VENT SYSTEM, the through the wall vent terminal in place and the first section of piping, up to first elbow , installed at the blower it is time to complete the install ...

  • A.O. Smith BTX-80 - page 13

    13 VENT A TTENUA TION ASSEMBL Y INST ALLA TION INSTRUCTIONS The V ent Attenuation Assembly (V AA) is designed to provide a reduction in noise that may be transmitted through the vent pipe. This installation of this V AA is optional. Review directions thoroughly prior to installing the new V AA. Please contact the manufacturer of the water heater as ...

  • A.O. Smith BTX-80 - page 14

    14 8. T ake the end of the tube at the bottom of the floor and route it to a suitable drain. This will provide an area where the condensate can drain without affecting the area around the appliance. 9. Once installed along with the rest of the vent configuration, make sure to operate the unit through at least one heat up cycle to ensure there is no ...

  • A.O. Smith BTX-80 - page 15

    15 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specific application you are attempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C. Know the reputation of your manufacturer and the ...

  • A.O. Smith BTX-80 - page 16

    16 Depth-of-entry mark Marking the depth of entry is a way to check if the pipe has reached the bottom of the fitting socket in step F . Measure the fitting depth and mark this distance on the pipe O.D. Y ou may want to add several inches to the distance and make a second mark as the primer and cement will most likely destroy your first one. Apply ...

  • A.O. Smith BTX-80 - page 17

    17 FOR YOUR SAFETY READ BEFORE LIGHTING TO TURN OFF GAS T O APPLIANCE OPERA TING INSTRUCTIONS 5. This appliance is equipped with a device which automatically lights the burner . DO NOT TR Y T O LIGHT THE BURNER BY HAND. 6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above o ...

  • A.O. Smith BTX-80 - page 18

    18 1. "W ake Up" the temperature indicators by holding down both the "COOLER" and "HOTTER" temperature adjustment buttons at the same time for one second (see Figure 14). One or two of the temperature indicators will light up. These indicators will only remain on for 30 seconds if no further buttons are pressed. After ...

  • A.O. Smith BTX-80 - page 19

    19 T & P V AL VE At least once a year , the temperature and pressure relief valve must be checked to ensure that it is in operating condition. Lift the lever at the top of the valve several times until the valve seats properly and operates freely . W ARNING THE W A TER P ASSING OUT OF THE V AL VE DURING THIS CHECKING OPERA TION MA Y BE EXTREMEL ...

  • A.O. Smith BTX-80 - page 20

    20 Anode deterioration depends on water conductivity , not necessarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Replacement of a depleted anode rod can extend the life of your water heater . Inspection should be con ...

  • A.O. Smith BTX-80 - page 21

    21 TROUBLESHOOTING For your safety , water heater service should be performed only by a qualified service technician. Read the GENERAL SAFETY INFORMA TION section first. W ARNING: DO NOT BY -PASS ANY CONTROLS TO MAKE HEA TER OPERA TE. OPERA TE ONL Y AS WIRED FROM F ACTOR Y . ...

  • A.O. Smith BTX-80 - page 22

    22 W A TER HEA TER CONTROL PROBLEM SOLUTION An open earth ground circuit to the 1. Check that the earth ground connection is ignition system. properly connected. 2. Check that the ground conductor on the water heater is properly connected. Wiring error or a high resistance to 1. Check for proper connection of line earth ground. neutral and hot wire ...

  • A.O. Smith BTX-80 - page 23

    23 Limited W arranty A. O. Smith Corporation, the warrantor , extends the following LIMITED WARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corros ion from potable water therein, during the first THREE years after initi ...

  • A.O. Smith BTX-80 - page 24

    24 ...

メーカー A.O. Smith カテゴリー Water Heater

A.O. Smith BTX-80のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- BTX-80の取扱説明書
- A.O. Smithの製品カード
- パンフレット
- またはA.O. Smith BTX-80の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、A.O. Smith BTX-80の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、A.O. Smith BTX-80の取り付け説明書、サービスマニュアル、簡易説明書、またはA.O. Smith BTX-80のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、A.O. Smith BTX-80の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

A.O. Smith BTX-80デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがA.O. Smith BTX-80を使用するのを助ける技術的文書のことです。説明書は通常、全てのA.O. Smith BTX-80ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

A.O. Smithの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. A.O. Smith BTX-80の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははA.O. Smith BTX-80の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。A.O. Smith BTX-80に関してこのドキュメントで見つけることができる全てのヒントの目次
3. A.O. Smith BTX-80デバイスの基本機能を使うにあたってのヒント。 A.O. Smith BTX-80のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。A.O. Smith BTX-80に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるA.O. Smith BTX-80のメーカー/サービスへの連絡先に関する情報。

A.O. Smith BTX-80についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもA.O. Smith BTX-80の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがA.O. Smith BTX-80で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)