Intel XP-P4S8X-VMの取扱説明書

24ページ 2.55 mb
ダウンロード

ページに移動 of 24

Summary
  • Intel XP-P4S8X-VM - page 1

    M - 0507 02 XP-P4S8X-VM Intel ® Pentium ® 4 Processor Motherboard User's Manual ...

  • Intel XP-P4S8X-VM - page 2

    Motherboard XP-P4S8X-VM Jul. 8, 2005 Jul. 8, 2005 XP-P4S8X-VM Motherboard Copyright Declaration © 2005 Gigatrend Technology Co., Ltd. All rights reserved. No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without express permission from Gigatrend Technology. Companies and product names mention ...

  • Intel XP-P4S8X-VM - page 3

    Contents Motherboard Layout ........................................................................ 4 1. Product Introduction .................................................................. 5 1.1. Feature Summary .............................................................................. 5 1.2. I/O Back Panel and Connectors & Jumper Sett ...

  • Intel XP-P4S8X-VM - page 4

    4 English Motherboard Layout XP-P4S8X-VM KB_MS COMA ATX_12V CD_IN F_AUDIO F_PANEL BATTERY SiS 964L SiS 661GX SOCKET 478 CPU_FAN ATX FDD IDE2 PCI1 PCI2 PCI3 DDR1 CODEC IT8705AF BIOS VGA IDE1 CLR_CMOS F_USB1 PWR_LED USB LAN DDR2 LPT ICS1883 AGP SYS_FAN AUDIO R_USB SUR_CEN ...

  • Intel XP-P4S8X-VM - page 5

    English 5 CPU Socket 478 for Intel ® Pentium ® 4 (Northwood, Prescott) with HT Technology Intel ® Pentium ® 4 800(overclock)/533MHz FSB L2 cache depends on CPU Chipset North Bridge: SiS ® 661 G X South Bridge: SiS ® 964L Memory 2 184-pin DDR DIMM sockets, supports up to 2GB DRAM (Max) Supports DDR400/DDR333/DDR266 DIMM Supports only 2.5V DDR ...

  • Intel XP-P4S8X-VM - page 6

    6 English PS/2 Keyboard PS/2 Mouse VGA Parallel Port COMA 1.2. I/O Back Panel and Connectors & Jumper Setting 1.2.2. Connectors & Jumper Setting FDD (Floppy Disk Drive Connector) The FDD connector is able to connect a single floppy disk drive via a FDD cable. Usually one edge of the FDD cable is marked in red, please attach this marked edge ...

  • Intel XP-P4S8X-VM - page 7

    English 7 CPU_FAN (CPU Fan Power Connector); SYS_FAN (System Fan Power Connector) The CPU_Fan power connector provides the largest amount of power to the CPU fan at 600mA. You can connect the casing fan to the SYS_FAN connector to enhance system cooling. ATX_12V (+12V Power Connector) The ATX_12V power connector provides power to the CPU. If this c ...

  • Intel XP-P4S8X-VM - page 8

    8 English F_AUDIO (Front Audio Connector) Connects to the audio connector located on the front panel of the system casing (dependent on case design). When use of the front panel audio connector is required, please remove the 5-6 pin, 9-10pin jumper. Please note that use of only the front panel audio connector or the rear panel audio connector is pe ...

  • Intel XP-P4S8X-VM - page 9

    English 9 The improper removal of the battery can result in harm. When replacing a battery, please make sure you use one that is of similar brand and model number. For information related to battery specifications and precautions, please refer to the manufacturer instructions. If you wish to delete the data stored in the CMOS, please follow the ste ...

  • Intel XP-P4S8X-VM - page 10

    10 English 2.1. Installation of a Pentium 4 CPU and Fan Sink 3 Position and attach the clips on one end of the fan sink firmly atop the CPU. Please do the same for the clips on the other end of the fan sink. 2 When the CPU is inserted into its position, gently press the metal lever downwards until a click is heard. Then add an even layer of heat si ...

  • Intel XP-P4S8X-VM - page 11

    English 11 2.3. Installation of the Graphics Card 1. Unfasten the clips on each end of the memory slots. Correctly align the memory module in the slot and push downwards.. 2. Once the memory module is correctly inserted, the clips will automatically refasten. If the memory module is positioned in the wrong direction, it will not insert. If this occ ...

  • Intel XP-P4S8X-VM - page 12

    12 English ...

  • Intel XP-P4S8X-VM - page 13

    English 13 3. BIOS Setup BIOS (Basic Input and Output System) stores all the information of the motherboard settings that is needed for system initiation within the CMOS. The CMOS SETUP utility allows the user to make changes in BIOS configurations that are required or to activate certain features. The CMOS SETUP saves each item configuration in th ...

  • Intel XP-P4S8X-VM - page 14

    14 English <F6> Gives the list of options available for each item <F7> Return to Optimized default values (not applicable to main setup screen) <F8> Enters BIOSNow! feature <F9> Displays system information <F10> Saves settings and exits setup 3.2. Standard CMOS Features ø Includes the settings for items such as date, ...

  • Intel XP-P4S8X-VM - page 15

    English 15 n Floppy 3 Mode Support Allows user to configure a Japanese standard 3 Mode floppy drive. Options: Disabled (No 3 Mode drive installed) Drive A (3 Mode Drive installed in A:) Drive B (3 Mode Drive installed in B:) Both (3 Mode Drive installed in A: and B:) n Halt on Tells the BIOS specifically which types of errors will halt the computer ...

  • Intel XP-P4S8X-VM - page 16

    16 English 3.3. Advanced BIOS Features ø Allows the configuration of advanced settings such as boot sequence, password check, etc. n First / Second / Third Boot Device The user can select the order in which the system will boot. Options: Floppy, LS120, HDD-0~HDD-3, SCSI, CDROM, ZIP, USB-FDD, USB-ZIP, USB-CDROM, USB-HDD, LAN, Disabled n Boot Up Flo ...

  • Intel XP-P4S8X-VM - page 17

    English 17 3.4. Integrated Peripherals ø This menu allows you to control the various ports of the computer such as IDE, SATA, USB, IEEE1394, COM port, LPT port, AC97 audio, etc. n IDE1 Conductor Cable Allows user to select the type of IDE1 conductor cable. Prior to selecting the setting, please make sure that the IDE device and cables support the ...

  • Intel XP-P4S8X-VM - page 18

    18 English n Onboard Parallel Port Allows the user to enable or disable the onboard parallel port. Options: 378/IRQ7, 278/IRQ5, 3BC/IRQ7, Disabled (default: 378/IRQ7) n Parallel Mode Use this to select the operation mode for the parallel port. (default: SPP) Options: SPP (normal) EPP (Enhanced Parallel Port) ECP (Extended Capabilities Port) ECP+EPP ...

  • Intel XP-P4S8X-VM - page 19

    English 19 n System After AC BACK Allows user to select system status when power is removed and returned. Options: Off (Always in off state when AC back) On (Always power on system when AC back) Laststate (System power on depends on the status before AC lost) (default:Off) n IRQ [3-7, 9-15], NMI When IRQ [3-7, 9-15] or NMI triggered, the suspend ti ...

  • Intel XP-P4S8X-VM - page 20

    20 English 3.6. PnP/PCI Configuration ø This menu allows you to configure your PCI slots. You can assign IRQ's for various PCI slots. n PCI 1 IRQ Assignment Allows user to assign an IRQ for the 1st PCI slot. Options: Auto,3,4,5,7,9,10,11,12,14,15 (default: Auto) n PCI 2 IRQ Assignment Allows user to assign an IRQ for the 2nd PCI slot. Options ...

  • Intel XP-P4S8X-VM - page 21

    English 21 3.7. PC Health Status ø This menu displays the current CPU temperature, the fan speeds, voltages etc. n Current Voltage(V) Vcore / DDR25V / +3.3V / +12V Automatically checks system voltage. n Current CPU Temperature Automatically checks CPU temperature. n Current CPU / SYSTEM FAN Speed (RPM) Automatically checks CPU/SYSTEM fan speed. n ...

  • Intel XP-P4S8X-VM - page 22

    22 English 3.8. MB Intelligent Tweaker(M.I.T.) ø This allows user to configure CPU frequency and voltage settings. ø This section is very dangerous for inexperienced users, and therefore it is not recommended that these settings be altered. An incorrect setting can result in system instability, corrupt data, or permanent hardware damage. n Config ...

  • Intel XP-P4S8X-VM - page 23

    English 23 3.9. Load Fail-Safe Defaults ø Use this option to reset your BIOS settings to the system defaults. You should only use this if you are encountering serious problems. Please select <Y> and <Enter> to load Fail-Safe defaults. Once this is loaded, your system may be slowed since this uses a minimal performance setting to allow ...

  • Intel XP-P4S8X-VM - page 24

    24 English 4. Driver Installation Driver installation for the Windows 98/98SE/200/ME/XP operating systems is simple. Once you insert the provided driver disks into your optical drive, the AUTORUN screen will appear. If this screen does not appear, you can use "D:setup.exe" (with "D" being the specified drive) to bring up the sc ...

メーカー Intel カテゴリー Computer Hardware

Intel XP-P4S8X-VMのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- XP-P4S8X-VMの取扱説明書
- Intelの製品カード
- パンフレット
- またはIntel XP-P4S8X-VMの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Intel XP-P4S8X-VMの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Intel XP-P4S8X-VMの取り付け説明書、サービスマニュアル、簡易説明書、またはIntel XP-P4S8X-VMのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Intel XP-P4S8X-VMの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Intel XP-P4S8X-VMデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがIntel XP-P4S8X-VMを使用するのを助ける技術的文書のことです。説明書は通常、全てのIntel XP-P4S8X-VMユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Intelの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Intel XP-P4S8X-VMの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははIntel XP-P4S8X-VMの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Intel XP-P4S8X-VMに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Intel XP-P4S8X-VMデバイスの基本機能を使うにあたってのヒント。 Intel XP-P4S8X-VMのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Intel XP-P4S8X-VMに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるIntel XP-P4S8X-VMのメーカー/サービスへの連絡先に関する情報。

Intel XP-P4S8X-VMについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもIntel XP-P4S8X-VMの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがIntel XP-P4S8X-VMで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)