York DJ 150の取扱説明書

28ページ 1.2 mb
ダウンロード

ページに移動 of 28

Summary
  • York DJ 150 - page 1

    036-2 1484-001- B-0103 FOR DI STRIB UTION USE ONL Y - NO T TO BE USED A T POINT O F RETA IL SAL E HIGH EFFICIENCY SINGLE P ACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNIT S DJ 150 12-1/2 NOMINAL TONS TECHN ICAL GUIDE T E C HNICA L GUIDE ® DESCRIPTION YORK ® Pr eda tor™ Magnu m i s a c onvert ibl e si ngle pa ckage unit with a co m ...

  • York DJ 150 - page 2

    036-2 1484-001- B-0103 2 Uni tary Prod uct s TABLE OF CO NTENTS DESC R IPTIO N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEAT URES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 FACT O RY INST ALLED OPT IONS . . . . . . . . . . . . . . 7 FIELD INSTAL LED ACCESSO RIES . . . . . . . . . . . . . 8 LIST OF FIGURES ...

  • York DJ 150 - page 3

    036-21 484-001- B-0103 Uni t a ry P rod uct s 3 FEA TURES • Hi g h E f fi ci e ncy – Hi gh ef fi ciency units are rated at 10.8 EER. Gas /elec tric un its have electroni c sp ark i gnit ion and po w er vented combusti on wit h stea dy st ate ef fici en- cies of 80%. These ef fici encies meet or exc eed all legis- lat ed mini mum lev els an d pr ...

  • York DJ 150 - page 4

    036-2 1484-001- B-0103 4 Unitary P roducts Both t he unit control board and i gnitio n contr ol board uti - li ze flash codes to ai d i n diagnosis of un it malfunct ions. Unique alarm code s quickl y iden tify the source of the uni t al ar m . All un it s use the same sta ndard fi lt er size. This st andar d- izat ion rem oves any confus ion on wh ...

  • York DJ 150 - page 5

    036-21 484-001- B-0103 Uni t a ry P rod uct s 5 and pro tect t he unit dur ing shi pment. The rai ls off er for k- li ft a ccess from 3 sides, and ri gging holes a re availa ble so tha t an over head cra ne can be us ed to pl ace the un its on a roof. • Easy I nst allat io n – Gas and el ect ric util ity knockout s ar e suppl ied in the un it u ...

  • York DJ 150 - page 6

    036-2 1484-001- B-0103 6 Uni tary Prod uct s • Honeywell BAS Control - The Honeywel l W7750C bu il di ng automati on system cont roll er is f actory i n st all ed. Incl udes ai r supp ly sens or , r eturn ai r sensor , di rty f ilter indi cator switch, and air provin g switch. • BAS Ready Econom iz e r - The economi zer is provi ded with a Bel ...

  • York DJ 150 - page 7

    036-21 484-001- B-0103 Uni t a ry P rod uct s 7 T ABLE 1: ACCES SO RIES Part Number Descri ption Weight 1RC0 47 0 Roo f Cu r b, 8" H eig ht - 1RC0 47 1 Roo f C urb, 14" H ei ght - 1RC0 47 2 Roo f Cu r b, T rans it i on (7.5 T thr oug h 12. 5 T) - 2T P0 45 1 182 5 El ec tr i c H ea t 18k W 23 0V - 2TP 0451 2425 Ele ctr ic H eat 24 kW 2 30V ...

  • York DJ 150 - page 8

    036-2 1484-001- B-0103 8 Uni tary Prod uct s D J 150 N 15 A 2 A AA 3 T ABLE 2: P R ODUCT NOMENCLATURE Model # Mo de l Nu mbe r De scription Optio ns D Pro duct Catego r y D = A i r Conditioner, Single P ackage J Pr oduct Identifi er J = High Efficien cy 150 Nominal Cooli ng Capacity MBH 150 = 12-1/2 T on N Heat T y pe C = Coo li n g Only N = Na tur ...

  • York DJ 150 - page 9

    036-21 484-001- B-0103 Uni t a ry P rod uct s 9 T ABLE 3: AI RFLO W ABBREVIATIONS ABBREVIA TION M E ANING BR Baromet r ic Relief EC Eco nomizer VEC V erti cal E cono mizer MD Motorized D amper PE Power Exhaus t SM S tanda rd Mot or BAS Build ing Auto mation System T ABLE 4: I NSTALLATI O N ABBREVIATIONS ABBREVIA TION M E ANING 1 Disc onnec t 2 Conv ...

  • York DJ 150 - page 10

    036-2 1484-001- B-0103 10 Uni tary Prod uct s T ABL E 6: PHYSICAL DA T A Component Model DJ 150 (12-1 /2) Evaporat or Blower Blo wer , Ce ntr i fuga l (Di a. X Wd. in.) 15 x 15 Moto r , S tan da r d (HP) 3 Moto r , O ptio nal ( HP) 5 Evaporat or Coil Rows 4 Fi ns p er Inc h 15 Height (in.) 4 0 Fac e Area (ft. 2 each) 13. 2 Condenser Fan (4 per Un i ...

  • York DJ 150 - page 11

    036-21 484-001- B-0103 Uni t a ry P rod uct s 11 T ABL E 7: DJ 150 (12-1/2 T O N) CAP ACITY RA TINGS Size (T ons) Mo d el Cooling Cap acity ARI Ratings * CFM Sound Rating (dB) † Nominal Electric Heat Capac ity ‡ (kW) Ga s He at Ca pa c it y Ga s Line Size (in. OD) MBH EER IPL V Input (MBH) O u tput (MBH) Sea sonal Effi cien cy (%) Te m p . Rise ...

  • York DJ 150 - page 12

    036-2 1484-001- B-0103 12 Uni tary Prod uct s *THE CAP ACITIES ARE GROSS RA TINGS. FOR NET CAPAC ITY , DEDUCT T H E SUPPL Y AIR BLOWER MOTOR H EA T , MBH = 3.415 X Kw. REFER TO THE APPROPRIA T E BLOWER PERFORMANCE T ABLE FOR THE KW OF T HE SUPPL Y AIR BLOWER M OTOR. +THESE RA T INGS INCLUDE CONDENSER F AN MOTOR AND C OMPRESSOR MOTOR POWER BUT NOT T ...

  • York DJ 150 - page 13

    036-21 484-001- B-0103 Uni t a ry P rod uct s 13 NOTE: Elect ric heaters are rated a t nominal volt age. Us e this ta ble t o dete rmine the el ectric heat capaci ty for h eaters su p- pli ed at lower vo lta ges. NOTES FOR T ABLES 1 2 AND T ABLE 1 3: • Blower per formanc e includes dr y coil and 2” t hrowaway filt ers . • Blower pe rforman ce ...

  • York DJ 150 - page 14

    036-2 1484-001- B-0103 14 Uni tary Prod uct s T ABL E 12: BLOWER PERFORMANCE 12-1/2 TO N SIDE DUCT CFM E xte rna l Stati c P re ssu re 0.2 0.4 0.6 0. 8 1.0 1. 2 1.4 1.6 1.8 2.0 RPM BH P W atts R P M BHP Wat ts R PM BHP Wa tts RPM BHP Wa tts RPM BHP W a t ts R PM B H P W atts RPM BHP Wa tts RPM BHP W a t ts R PM BHP W att s RPM BHP Wa tts 3700 ---- ...

  • York DJ 150 - page 15

    036-21 484-001- B-0103 Uni t a ry P rod uct s 15 T ABLE 1 3: BLOWER P E R FO RMANCE 12-1/2 TON DOWNSHOT CFM External St atic Pressure 0.2 0. 4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 RPM BHP Wa tts RPM BHP Wa tts RP M BHP Wa tt s RPM BHP W att s RPM BH P W atts RP M BHP Wa tts RP M BHP Wat t s R PM BH P W atts RP M BHP Wa tts RP M BHP Wat t s 3700 ---- --- ...

  • York DJ 150 - page 16

    036-2 1484-001- B-0103 16 Uni tary Prod uct s T ABL E 14: ADDITIONAL STATIC RESI STANCE CFM Cooling Only * Economizer † ‡ Elect ri c Heat KW † 18 24 36 54 3700 0. 20 0.0 4 0. 18 0. 21 0.2 2 0. 26 3900 0. 23 0.0 4 0. 20 0. 23 0.2 4 0. 28 4100 0. 25 0.0 4 0. 22 0. 25 0.2 6 0. 31 4300 0. 28 0.0 5 0. 24 0. 28 0.2 9 0. 34 4500 0. 30 0.0 5 0. 26 0. ...

  • York DJ 150 - page 17

    036-21 484-001- B-0103 Uni t a ry P rod uct s 17 FIGUR E 2 : U N I T 4 P OIN T LOA D T ABL E 16: 4 POINT L OAD WEIGHT Mod el Loc ati on (lbs.) ABCD DJ 15 0 282 323 42 4 37 1 FIGURE 3 : UNIT CENTER OF G RAVITY A D B C LEFT FRONT 47-½" 25-½" LEFT FRONT FI GURE 4 : UN IT W I TH 6 PO INT LOA D T ABLE 17: 6 POINT L OAD WEIGHT Model Loc ati o ...

  • York DJ 150 - page 18

    036-2 1484-001- B-0103 18 Uni tary Prod uct s FIGURE 5 : UNIT DIMENSI O NS 50-3/ 4 4-1/4 59 30-3/16 24-3/16 17-3/ 16 27 89 11-1/2 LEFT FRONT For Drain Dimensions See Detail C See Detail A 119-7/16 Power Entry 2-1/2 Con- venience Outlet For Baserail Dimensions See Detail B 6-3/16 30-11/32 Control Entry 7/8 Con- venience Outl et Power Entry 7/8 T ABL ...

  • York DJ 150 - page 19

    036-21 484-001- B-0103 Uni t a ry P rod uct s 19 FIGURE 6 : PREDATOR™ MAGNUM ROOF CURB DIMENSIO NS 8 o r 1 4 5 0 - 1 / 2 3 0 2 0 2 0 8 0 - 5 / 8 6 2 T Y P . I N S U L A T E D D E C K U N D E R C O M P R E S S O R S E C T I O N I N S U L A T E D D E C K U N D E R C O N D E N S E R S E C T I O N F R O N T R I G H T S U P P L Y R E T U R N FIGURE 7 ...

  • York DJ 150 - page 20

    036-2 1484-001- B-0103 20 Uni tary Prod uct s FIGURE 8 : BO TTOM DUCT OPENI NG S (FROM ABOVE) 14- 23/32 16-3/8 18-1/16 19-5/8 63-1/2 7-1/8 17-3/16 19-3/16 21-3/16 6-13/16 32-11/16 6-13/16 6-13/16 27-1/2 18 21 24 Return Air Supply Air Bottom Condensate Entry FRONT Bottom Power, Control and Convenience Outlet Wiring Entries Bottom Gas Supply Entry 12 ...

  • York DJ 150 - page 21

    036-21 484-001- B-0103 Uni t a ry P rod uct s 21 FIGURE 10 : DOWNF LOW ECONOM IZER HOOD DET AIL 58-¼" 35-¾" 26" 25-¾" 25-¾" 119-7/16" 47-½" 30-¼" OUTSIDE AIR INTAKE HOOD YORK PREDATOR ROOFTOP UNIT RELIEF HOOD FOR POWER EXHAUST OR BAROMETRIC RELIEF ...

  • York DJ 150 - page 22

    036-2 1484-001- B-0103 22 Uni tary Prod uct s FIGURE 1 1 : CO OL ING UNIT WIT H GAS HEAT WIRING 23 0 V . DIAGRAM ...

  • York DJ 150 - page 23

    036-21 484-001- B-0103 Uni t a ry P rod uct s 23 FIGURE 12 : COOLING UNIT W/WO EL ECT RIC HEAT WIRI NG DIAGRAM ...

  • York DJ 150 - page 24

    036-2 1484-001- B-0103 24 Uni tary Prod uct s FIGURE 13 : CO OL ING UNIT WITH GAS HEAT WIRING 460, 575 & 50 H Z DIAGRAM ...

  • York DJ 150 - page 25

    036-21 484-001- B-0103 Uni t a ry P rod uct s 25 MECHANICAL SP ECIFICA TIONS SINGLE P ACKAGE AIR COOLED GAS/ELECT RIC UNITS FOR 12.5 NOMINAL TONS PREDA TOR™ MAGNUM - DJ 150 10.8 E ER GENERAL Unit s shall be ma nuf actured by Y ork Intern ati ona l Unit ary Produc ts Group i n an ISO 9001 cer tifie d f aci lity . YORK® Predat or™/Magnum uni ts ...

  • York DJ 150 - page 26

    036-2 1484-001- B-0103 26 Uni tary Prod uct s nate any moi sture or for eign matter . C. Acce ssibl e s ervice gage conne ct i ons on both sucti on and di scharg e lines to charg e, eva cuate, and meas ure r efriger ant pr essure duri ng any n ecessary s ervic ing or troubl eshooting , wit hout losing charg e. D. The unit shal l hav e t w o in depe ...

  • York DJ 150 - page 27

    036-21 484-001- B-0103 Uni t a ry P rod uct s 27 the desi gn CFM of outd oor ai r to meet the venti l ation requi rement s of the cond it io ned space dur ing normal operat ion. Whenever the indoor fan motor is en ergized, the damper s open up to one of two pr e- select ed posi - ti ons – r egardl ess of the ou tdoor ai r en thalpy . Dampers ret ...

  • York DJ 150 - page 28

    Subjec t to change without not i ce. Printed in U.S.A. 036-2 1484-001- B-0103 Copyri ght © by Unitary Product s 2003. All ri ght s reserve d. Supe rse des: 036-2 1484-001-A-0 902 Un itar y 500 5 No r ma n Product s Y ork OK Group Drive 73 069 ...

メーカー York カテゴリー Air Conditioner

York DJ 150のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DJ 150の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork DJ 150の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York DJ 150の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York DJ 150の取り付け説明書、サービスマニュアル、簡易説明書、またはYork DJ 150のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York DJ 150の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York DJ 150デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork DJ 150を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork DJ 150ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York DJ 150の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork DJ 150の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York DJ 150に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York DJ 150デバイスの基本機能を使うにあたってのヒント。 York DJ 150のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York DJ 150に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork DJ 150のメーカー/サービスへの連絡先に関する情報。

York DJ 150についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork DJ 150の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork DJ 150で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)