    ODSHR Series Outdoor W oodbur ning Fireplace Homeowner's Installation & Operating Manual DO NOT DISCARD THIS MANUAL: Retain for future use. 20002264 2/03 Rev . 9 Model: ODSHR42 2264 Underwriter's Laboratories Report No. MH20546 ...

  • Majestic ODSHR42 - page 2

    2 ODSHR Series 20002264 Safety Infor mation PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty . Description The ODSHR Series (Super Hearth) firepla ...

  • Majestic ODSHR42 - page 3

    3 ODSH R Series 20002264 Rough Opening Height 42" 52 ¹⁄₄ " 44" ³⁄₄ " ³⁄₄ " 24 " 7⁷⁄₁₆ " 13 ³⁄₈ " Dia. Rough Opening Width 53 ³⁄₄ " Rough Opening Depth 62 ¹⁄₈ " 62 ¹⁄₈ " 87⁷⁄₈ " 10³⁄₈ " 26³⁄₄ " 35 " 48 ¹⁄₄ " ...

  • Majestic ODSHR42 - page 4

    4 ODSHR Series 20002264 NOTE: If the fireplace is a freestanding unit, it must be located a minimum of 10' from the opening of the firebox to a combustible structure. A minimum height of 6'- 4" measured from the base of the firebox to the bottom of the termination cap is permitted. 10' Min. 6'4" Min. FP1001 Fig. 3 Free ...

  • Majestic ODSHR42 - page 5

    5 ODSH R Series 20002264 Chimney Requirements - Offset Installations 0000 0 3 " 1 1 " 1000 0 8 ¹⁄₄ " 20" 0100 0 1 1 ¹⁄₄ "2 5 ¹⁄₄ " 2000 0 1 3 ¹⁄₂ "2 9 ¹⁄₄ " 1100 0 1 6 ¹⁄₂ "3 4 ¹⁄₄ " 0010 0 2 0 ¹⁄₄ "4 0 ³⁄₄ " 2100 0 2 1 ³⁄₄ "4 3 ¹⁄? ...

  • Majestic ODSHR42 - page 6

    6 ODSHR Series 20002264 Planning Infor mation The T en Foot Rule Major U.S. building codes specify a minimum chimney height above the roof top. The “T en Foot Rule” is a fire safety rule and not a draft rule. T o ensure proper draft, it is recommended that you always meet or exceed the “T en Foot Rule,” especially when installing a termina- ...

  • Majestic ODSHR42 - page 7

    7 ODSH R Series 20002264 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30 feet above the hearth. Chimney supports are required if the vertical height exceeds 30 feet with 1 1CF chimneys. Locate chimney supports at ceiling holes or other structural framing at 30 foot heights. Spacing between ...

  • Majestic ODSHR42 - page 8

    8 ODSHR Series 20002264 Locate center point of the chimney on ceiling as though a straight up chimney arrangement is to be used. Measure your offset dimension from straight up chim- ney center point on ceiling. Ceiling Chimney Hole/ Possible Obstructions The size of the hole in ceiling will vary with the angle at which the chimney passes through ce ...

  • Majestic ODSHR42 - page 9

    9 ODSH R Series 20002264 Cutting the Hole Cover fireplace collar opening and cut proper sized chimney hole in chimney . (Fig. 10 & 1 1) Framing the Ceiling Hole Frame the ceiling chimney hole as shown in Figure 1 1. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level. The f ...

  • Majestic ODSHR42 - page 10

    10 ODSHR Series 20002264 4. Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Lift the fireplace front slightly and slide the metal safety strips under front bottom edge about 1 ¹⁄₂ inches, allowing the remainder to extend in front of firebox. Overlap strips at least 1/2 inch to provide a positive joint. (Flat s ...

  • Majestic ODSHR42 - page 11

    11 ODSH R Series 20002264 5. Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 14. When you get a good lock, you will hear the pipe clearly snap to- gether . Once sections are snap-locked in place, it is extremely difficult to get them apart. Make ...

  • Majestic ODSHR42 - page 12

    12 ODSHR Series 20002264 Firestop spacers are not available for , nor are they required on, vertical walls. The Majestic Fireplaces' chimney components have been tested and approved with the area where the outer pipe slides through the firestop spacer sealed with a noncombustible caulk if desired, or left com- pletely open with no sealant. Con ...

  • Majestic ODSHR42 - page 13

    13 ODSH R Series 20002264 7. Finish W all Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12 inches above the front opening. If a combustible material is used below a flat mantel shelf, consult your local building codes for minimum clearance from top of fireplace opening to bottom of mantel shelf. A ...

  • Majestic ODSHR42 - page 14

    14 ODSHR Series 20002264 Stud 2 x 4 Finished Header Covered W all Ledge Bracket Finished W all Noncombustible Decorative Facing Must be Sealed with Noncombustible Material Surround FP1 167 Fig. 20 Facing on fireplace surround flush with finished wall. Side W all Protection Adjacent combustible side walls that are within dimen- sions shown in Figure ...

  • Majestic ODSHR42 - page 15

    15 ODSH R Series 20002264 8. Hearth Installation A hearth extension is required to protect a combustible floor in front of the fireplace. See Figure 24 for mini- mum dimensions and mounting detail. NOTE: Hearth Extension must not cover the air inlet opening of a fireplace. The hearth extension described in Figure 24 must be a durable noncombustible ...

  • Majestic ODSHR42 - page 16

    16 ODSHR Series 20002264 COMMON MA TERIALS AND F A CT ORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (Majestic Products Company) R V alue is for ¹⁄₂ inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material FP533ADD Fig. 25 Hearth extension material factors. Seal Cracks Between ...

  • Majestic ODSHR42 - page 17

    17 ODSH R Series 20002264 From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screw- driver or small chisel and hammer , carefully tap around the knockout until it loosens and falls out. Install 1/2 inch certified gas pipe through op ...

  • Majestic ODSHR42 - page 18

    18 ODSHR Series 20002264 2264 *T wo (2) required ** Four (4) required V ermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 1 2 5 7 6 4 3 12 11 8 10 9a,b 13 Ref. Description Part Number 1. Damper Blade 3990185 2. Damper Ha ...

  • Majestic ODSHR42 - page 19

    19 ODSH R Series 20002264 The following accessories for this appliance are available from your local V ermont Castings, Majestic Products products distributor . Should you need additional information beyond what your distributor can furnish, contact: V ermont Castings, Majestic Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn ...

  • Majestic ODSHR42 - page 20

    20 ODSHR Series 20002264 Accessory Description Model No. Extended Round T op Chimney Sections Chimney Elbows T op Housing with Upper Baffle Chimney Reducer Kit For use with Majestic T ype "1 1CF" Chim- ney Systems. Used to terminate chimney at top of chase. Adapter kit included. Flashing not included. Used to build "1 1CF" chimn ...

  • Majestic ODSHR42 - page 21

    21 ODSH R Series 20002264 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For V er mont Castings, Majestic Products PRE-ENGINEERED Fireplace Systems V ermont Castings, Majestic Products warrants its Pre-Engineered Fireplace (“Fireplace”) and the V ermont Castings, Majestic Products- supplied firegrate, glass doors, outside air system, fan motor ...

  • Majestic ODSHR42 - page 22

    22 ODSHR Series 20002264 © V ermont Castings, Majestic Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com Ve r mont Castings, Majestic Products ...

メーカー Majestic カテゴリー Outdoor Fireplace

Majestic ODSHR42のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ODSHR42の取扱説明書
- Majesticの製品カード
- パンフレット
- またはMajestic ODSHR42の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Majestic ODSHR42の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Majestic ODSHR42の取り付け説明書、サービスマニュアル、簡易説明書、またはMajestic ODSHR42のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Majestic ODSHR42の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Majestic ODSHR42デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMajestic ODSHR42を使用するのを助ける技術的文書のことです。説明書は通常、全てのMajestic ODSHR42ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Majesticの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Majestic ODSHR42の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMajestic ODSHR42の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Majestic ODSHR42に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Majestic ODSHR42デバイスの基本機能を使うにあたってのヒント。 Majestic ODSHR42のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Majestic ODSHR42に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMajestic ODSHR42のメーカー/サービスへの連絡先に関する情報。

Majestic ODSHR42についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMajestic ODSHR42の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMajestic ODSHR42で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)