Mitsubishi Electronics FR-D700の取扱説明書

11ページ 0.21 mb
ダウンロード

ページに移動 of 11

Summary
  • Mitsubishi Electronics FR-D700 - page 1

    INVERTER FR-D700 Safety stop function instruction manual CONTENTS 1. General description ............................................................................. 1 2. Inst allation and wiring ......................................................................... 2 3. Example of safety system configuration ................................... ...

  • Mitsubishi Electronics FR-D700 - page 2

    Compliance with the EU Machinery Directive – Functional Safety DANGER Any misuse of safety function could lead to personal injury or death , property damage, or economic loss. To ensure that the system complies full y with require ment of safety, make a system-level ri sk assessment. Mitsubishi Electric Co. cannot assu me responsibility for any s ...

  • Mitsubishi Electronics FR-D700 - page 3

    1 1. General description Features Mitsubishi FR -D700 safety stop function prevent s a drive from supplying rot ational energy to motors. Dual safety channels ‘S1’ and ‘S2’ cut of f the gate-drive power for IGBT to turn off. Fig.1 FR-D700 safety stop function diagram DANGER The safety stop function doesn’t isol ate electrically between dr ...

  • Mitsubishi Electronics FR-D700 - page 4

    2 2. Inst allation and wiring ATTENTION The following information is merely a guide for prope r installation. Mitsubishi Electric Co. cannot assu me responsibility for the compliance or the noncomplia nce to any code, national, local or otherwise for the pro per installation of this equipment. A hazard of personal injury and/or eq uipment damage ex ...

  • Mitsubishi Electronics FR-D700 - page 5

    3 Wiring The safety related terminals are d escribed in T able.2 and T able.3 T able.2 The safety related terminals T able.3 T ruth table of Safety related signals Input power S1-SC S2-SC Failure SO-SC RUN-SE or A-C Drive state OFF - - - OFF(Open) OFF(Open) Drive shutoff (Safe state) No failure OFF(Open) ON(Close) Drive enable Short Short Detected ...

  • Mitsubishi Electronics FR-D700 - page 6

    4 Wire and ferrule specification T able.4 wire and ferrule specification Wire size (mm 2 ) Ferrule with insulation collar * Crimping tool * 0.3 / 0.5 AI 0,5-10WH 0.75 AI 0,75-10GY 1 AI 1-10RD 1.25 / 1.5 AI1,5-10BK 0.75 (combined 2 wire) AI TWIN 2 X 0,75-10GY CRIMPFOX ZA3 *Ferrules and tools are dist ributed by Phoenix Conta ct. Jumper cable The jum ...

  • Mitsubishi Electronics FR-D700 - page 7

    5 3. Example of safety system configuration Example 1 Fig.3 Safety system example 1 – STOP asynchronous with EM and fault detecti on through A-C output. For safety stop, configure the wiring as shown in Fig.3 above. Note: the above wiring is configured to prevent resta rt in case of a fault. The parameter No.1 92 must be set to ‘199’. This se ...

  • Mitsubishi Electronics FR-D700 - page 8

    6 * When connecting multiple i nverters, use a diode on the eac h safety input terminal to preve nt a malfunction due to undesirable current. Fig.4 Example of multiple inverters connected to a safety relay unit The number of inverters connected to a safety relay uni t should be decided under considerat ions of output terminal rating of a safety rel ...

  • Mitsubishi Electronics FR-D700 - page 9

    7 Example 2 Fig.5 Safety system example 2 – STOP synchronous with EM and fault detectio n through RUN output. For safety stop, configure the wiring as shown in Fig.4 above. Note: the above wiring is configured to prevent resta rt in case of a fault. XS0 should be connected to RUN termi nal and XS1 should be connecte d to SE, because polarity of X ...

  • Mitsubishi Electronics FR-D700 - page 10

    8 4. T est and checking failure ATTENTION T o avoid systematic faults, a test even for faulty demands of the safety function has to be performed in order to check the correct function of the monitor signal. This test shall be carried out at system installation, any software changes, parameterization changes, and/or at least once per year . I/O st a ...

  • Mitsubishi Electronics FR-D700 - page 11

    REVISIONS Print Date Manual Number Revision Aug. 2009 BCN-A211508-000- C First edition Dec. 2009 BCN-A211508- 000-D Change Example of Safety stop conne ction ...

メーカー Mitsubishi Electronics カテゴリー Marine Battery

Mitsubishi Electronics FR-D700のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- FR-D700の取扱説明書
- Mitsubishi Electronicsの製品カード
- パンフレット
- またはMitsubishi Electronics FR-D700の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Mitsubishi Electronics FR-D700の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Mitsubishi Electronics FR-D700の取り付け説明書、サービスマニュアル、簡易説明書、またはMitsubishi Electronics FR-D700のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Mitsubishi Electronics FR-D700の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Mitsubishi Electronics FR-D700デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがMitsubishi Electronics FR-D700を使用するのを助ける技術的文書のことです。説明書は通常、全てのMitsubishi Electronics FR-D700ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Mitsubishi Electronicsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Mitsubishi Electronics FR-D700の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははMitsubishi Electronics FR-D700の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Mitsubishi Electronics FR-D700に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Mitsubishi Electronics FR-D700デバイスの基本機能を使うにあたってのヒント。 Mitsubishi Electronics FR-D700のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Mitsubishi Electronics FR-D700に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるMitsubishi Electronics FR-D700のメーカー/サービスへの連絡先に関する情報。

Mitsubishi Electronics FR-D700についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもMitsubishi Electronics FR-D700の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがMitsubishi Electronics FR-D700で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)