    DX8200A-3002 QUICK GUIDE DX8200A-3002 General View: Figure A Laser Beam Output Window s 1 Mount ing Sl ot s 2 Laser Safety Lab el 3 Mounting Referen ce Label 4 Figure B Progr amming Keypad 1 Phase On LED (Yellow) 3 Power On LED (Green) 2 TX Dat a LED (Green) 5 Network LED (Red) 6 Encoder LED (Yell ow) 4 LCD Displ ay 7 Figure C Lonworks 17-pin Male ...

  • Datalogic DX8200A-3002 - page 2

    DX8200A-3002 QUICK GUIDE 2 Technical Features: ELECTRICA L FEATURES Supply voltage 20 to 30 Vdc Power consumption 30 W typical 35 W Max. (including startup current) Communication Interfaces A uxiliary Baud Rate RS232 1200 to 115200 Other Lonworks 1.25 Mb/s OPTICA L FEA TURES Light receiver Avalanche photodiode Wavelength 630 to 680 nm Saf et y cla ...

  • Datalogic DX8200A-3002 - page 3

    DX8200A-3002 QUICK GUIDE 3 ENVIRONMENTA L FEATURES Operating temperature 0° to +50 °C (+32° to +122 °F) Storage temperature -20° to +70 °C (-4° to +158 °F) Humidity 90% non condensing Ambient light immunity 20000 lux Vibration resistance: EN 60068-2-6 2 hours on each axis Frequency range from 5 to 150 Hz; Constant displacement 3 mm pk-pk fr ...

  • Datalogic DX8200A-3002 - page 4

    DX8200A-3002 QUICK GUIDE 4 Electrical Connections: Two 17-pin connectors provide access to the scanner’s local Lonworks netw ork used for both input and output connections to build a multi-sided or omni-station system. 17-pin Lonworks Connector Pinout Pin Name Function A1 GND Supply voltage (negative pin) A2 VS Supply voltage 20 to 30 Vdc (positi ...

  • Datalogic DX8200A-3002 - page 5

    DX8200A-3002 QUICK GUIDE 5 Connectivity: DX8200A-3002 Ty pical Lay out Extended I/O Host HUB ETHERNET SC6000 AUX CAB-SC6003 CAB-SC6003 Power/Net VAC INPUT CAB-SC6103 Cable PWO LONWORKS ENCODER PS PS Aux CAB-850x CAB-850x CAB-850x CAB-850x up to 3 scanners per branch BTK8500 Bus Return DX8200A-3002 DS8100A-3002 CAB-850x up to 4 scanners per branch B ...

  • Datalogic DX8200A-3002 - page 6

    DX8200A-3002 QUICK GUIDE 6 Example of Redundant System Lay out AUX CAB-SC6103 Extended I/O ETHERNET SC6000 CAB-SC6003 CAB-SC6003 Power/Net VAC INPUT PWO LONWORKS ENCODER PS PS Aux CAB-850x CAB-850x BTK8500 CAB-850X CAB-850x CAB-850x Extended I/O ETHERNET SC6000 CAB-SC6003 CAB-SC6003 Power/Net VAC INPUT PWO CAB-PWO 03 Redundancy CAB-850X CAB-850x CA ...

  • Datalogic DX8200A-3002 - page 7

    DX8200A-3002 QUICK GUIDE 7 Example of Redundant System ...

  • Datalogic DX8200A-3002 - page 8

    DX8200A-3002 QUICK GUIDE 8 Mechanical Installation: DX8200A-3002 can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the sides of t he scanner for mounting. The d ia g ra m be l ow ca n be use d fo r in st al lat ion ; ref er t o th e R eading Diagrams for correct positioning of the scanner with respect to the reading zo ...

  • Datalogic DX8200A-3002 - page 9

    DX8200A-3002 QUICK GUIDE 9 Reading Diagrams: Note: x = 0 and z = 0 correspond to the edge of t he DX 8200A-3002 scanner as shown in the figure below . DX8200A-3002 (0.50 mm/20 mils) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 0 -24 -40 (in) -32 -48 0 -60 -80 (cm) -100 -120 -140 -160 -56 -64 (in) -30 -20 0 -10 (cm) -50 -60 -70 -40 30 20 ...

  • Datalogic DX8200A-3002 - page 10

    DX8200A-3002 QUICK GUIDE 10 The laser beam can be switched off through a softwar e command (see also the Genius™ Help On-Line). LASER LIGHT DO NOT ST ARE INTO BE AM CLASS 2 LASER PROD UCT MAXIMUM OUT PUT RADI ATION 1 m W EMITTED WA VELENGTH 630~680 nm TO EN 6082 5-1: 2001 CAUTION-C LASS 3B LASER LIGHT W HEN OPEN AVOID EXPOSURE TO BEAM LA SER LIGH ...

  • Datalogic DX8200A-3002 - page 11

    DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DX8200A-XXXX , Laser Scanner e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo ...

メーカー Datalogic カテゴリー Scanner

Datalogic DX8200A-3002のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DX8200A-3002の取扱説明書
- Datalogicの製品カード
- パンフレット
- またはDatalogic DX8200A-3002の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Datalogic DX8200A-3002の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Datalogic DX8200A-3002の取り付け説明書、サービスマニュアル、簡易説明書、またはDatalogic DX8200A-3002のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Datalogic DX8200A-3002の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Datalogic DX8200A-3002デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがDatalogic DX8200A-3002を使用するのを助ける技術的文書のことです。説明書は通常、全てのDatalogic DX8200A-3002ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Datalogicの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Datalogic DX8200A-3002の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははDatalogic DX8200A-3002の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Datalogic DX8200A-3002に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Datalogic DX8200A-3002デバイスの基本機能を使うにあたってのヒント。 Datalogic DX8200A-3002のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Datalogic DX8200A-3002に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるDatalogic DX8200A-3002のメーカー/サービスへの連絡先に関する情報。

Datalogic DX8200A-3002についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもDatalogic DX8200A-3002の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがDatalogic DX8200A-3002で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)