  • Hans Grohe ShowerArc 26396001 - page 1

    ShowerArc 26396001 Installation Instructions / W arranty ...

  • Hans Grohe ShowerArc 26396001 - page 2

    2 ShowerArc 26396001 Minimum ceiling height – 90 1/2” ...

  • Hans Grohe ShowerArc 26396001 - page 3

    3 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber . Please read over these instructions thor- oughly before beginning installation. Make sure that you have all tools and sup- plies needed to complete the installation. Inspect the ShowerArc thoroughly for ship- ping damage before beginning insta ...

  • Hans Grohe ShowerArc 26396001 - page 4

    4 Installation in 90º corner: Instructions begin on page 5 W all-to-wall installation Requires 26397000 installation kit (included): Instructions begin on page 13. Roughing-in The ShowerArc requires 1/2” NPT female fittings, recessed 3/8” behind the surface of the finished wall, for the hot and cold water supplies for the thermostatic mixing v ...

  • Hans Grohe ShowerArc 26396001 - page 5

    5 Only one set of supplies is required – do not install two sets of supplies . Installation in 90º corner The thermostatic mixing valve may be installed on either wall. This diagram shows both possible positions for the installation. ...

  • Hans Grohe ShowerArc 26396001 - page 6

    6 Installation in 90º Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4 ...

  • Hans Grohe ShowerArc 26396001 - page 7

    7 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8 ...

  • Hans Grohe ShowerArc 26396001 - page 8

    8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 9 10 11 12 6 mm ...

  • Hans Grohe ShowerArc 26396001 - page 9

    9 13 14 15 16 ...

  • Hans Grohe ShowerArc 26396001 - page 10

    10 1 2 17 18 19 20 6 mm ...

  • Hans Grohe ShowerArc 26396001 - page 11

    11 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 21 22 23 24 6 mm ...

  • Hans Grohe ShowerArc 26396001 - page 12

    12 T urn to page 22 to continue the installation. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 25 26 ...

  • Hans Grohe ShowerArc 26396001 - page 13

    13 The thermostatic mixing valve may be installed on either wall. The diagram shows both possible positions for the installation. Only one set of supplies is required – do not install two sets of supplies . W all-to-W all Installation ...

  • Hans Grohe ShowerArc 26396001 - page 14

    14 W all-to-W all Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4 ...

  • Hans Grohe ShowerArc 26396001 - page 15

    15 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8 ...

  • Hans Grohe ShowerArc 26396001 - page 16

    16 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 1 2 6 mm 12 9 10 11 ...

  • Hans Grohe ShowerArc 26396001 - page 17

    17 Install the 26397000 mounting set 13 14 15 16 ...

  • Hans Grohe ShowerArc 26396001 - page 18

    18 XX 90 XX = 17 18 19 20 ...

  • Hans Grohe ShowerArc 26396001 - page 19

    19 6 mm SW 3 mm M6x8 1 2 24 21 22 23 ...

  • Hans Grohe ShowerArc 26396001 - page 20

    20 Install the 26397000 mounting set M6x60 1. 2. 3. SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an- chors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 ...

  • Hans Grohe ShowerArc 26396001 - page 21

    21 T urn to page 22 to continue the installation. SW 3 mm M6x8 29 ...

  • Hans Grohe ShowerArc 26396001 - page 22

    22 Install the Cover , Escutcheon, and Handle Install the Showerhead and Handshower 2 1 ...

  • Hans Grohe ShowerArc 26396001 - page 23

    23 Reset the High T emperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. T ur n the stop unit to the handshower position. T ur n the temperature control stem until the output water is the desired high temperature -- usually 110º. KLICK 1 2 3 4 ...

  • Hans Grohe ShowerArc 26396001 - page 24

    24 T ur n the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. T ighten the handle screw with a 3 mm Allen wrench. KLICK SW 3 mm 5 6 7 ...

  • Hans Grohe ShowerArc 26396001 - page 25

    25 Justify the Handle T ur n the diverter handle to the handshower position. T ur n the temperature control knob until the output water is 100ºF . T ur n the diverter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle. Align the indexing mark on the temperature control knob with the 100º mark. Replace ...

  • Hans Grohe ShowerArc 26396001 - page 26

    26 User Instructions Using the Handshower T ur n the function lever to until the desired spray mode has been obtained. T ur n the temperature control knob to change the tem- perature. T ur n it clockwise to make the water cooler , counter-clockwise to make the water warmer . When the knob is turned counter-clockwise to the 100º position it will st ...

  • Hans Grohe ShowerArc 26396001 - page 27

    27 If necessar y , pour about 3/4” of a commercial scale remover , such as Lime-A way or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water . Reinstall the handshower . Flush the handshower for at least one minute before using. The handshower uses the Rubit? ...

  • Hans Grohe ShowerArc 26396001 - page 28

    28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25 ...

  • Hans Grohe ShowerArc 26396001 - page 29

    29 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 97603000 9 showerhead 97195001 10 handle 25971000 11 shutoff unit with selector 97976000 12 escutcheon 97491000 13 thermostat car tridge 94282000 14 noise re ...

  • Hans Grohe ShowerArc 26396001 - page 30

    30 Problem Possible Cause Solution Unit outputs both hot and cold water , but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing W ater temperature does not get hot enough high temperature limit stop not set correctly reset high temperature limit stop handle not justified justify the handle thermosta ...

  • Hans Grohe ShowerArc 26396001 - page 31

    31 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY ...

  • Hans Grohe ShowerArc 26396001 - page 32

    Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No. 90404701 • Revised 12/2007 the product for use primarily for any other purpose, including, without limitation, a commercial purpose, this warranty extends only (i) for ...

メーカー Hans Grohe カテゴリー Plumbing Product

Hans Grohe ShowerArc 26396001のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- ShowerArc 26396001の取扱説明書
- Hans Groheの製品カード
- パンフレット
- またはHans Grohe ShowerArc 26396001の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Hans Grohe ShowerArc 26396001の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Hans Grohe ShowerArc 26396001の取り付け説明書、サービスマニュアル、簡易説明書、またはHans Grohe ShowerArc 26396001のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Hans Grohe ShowerArc 26396001の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Hans Grohe ShowerArc 26396001デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHans Grohe ShowerArc 26396001を使用するのを助ける技術的文書のことです。説明書は通常、全てのHans Grohe ShowerArc 26396001ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Hans Groheの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Hans Grohe ShowerArc 26396001の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHans Grohe ShowerArc 26396001の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Hans Grohe ShowerArc 26396001に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Hans Grohe ShowerArc 26396001デバイスの基本機能を使うにあたってのヒント。 Hans Grohe ShowerArc 26396001のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Hans Grohe ShowerArc 26396001に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHans Grohe ShowerArc 26396001のメーカー/サービスへの連絡先に関する情報。

Hans Grohe ShowerArc 26396001についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHans Grohe ShowerArc 26396001の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHans Grohe ShowerArc 26396001で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)