  • Omega HHLM-1MV - page 1

    OMEGA HHLM-1MV Light T ransducer ...

  • Omega HHLM-1MV - page 2

    OMEGAnet SM On-Line Service http://www.omega.com Internet e-mail info@omega.com For immediate technical or application assistance: USA and Canada: Mexico and Latin America: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Tel: (95) 800-TC-OMEGA SM Customer Service: 1-800-622-2378 / 1-800-622-BEST SM FAX: (95) 203-359-7807 Engineering Service: 1-80 ...

  • Omega HHLM-1MV - page 3

    INTRODUCTION This instrument is a portable easy use, compact-sized light transducer designed for simple one hand operation. Provides lux unit measurements. SAFETY INFORMATION It is recommended that you read the safety and operation instructions before using the lightmeter. WARNING • To avoid electric shock, do not operate this product in wet or d ...

  • Omega HHLM-1MV - page 4

    2 SPECIFICATIONS GENERAL Low battery indication: the "Red LED" is displayed when the battery voltage drops below the operating level. Operating Environment: 0°C to 50°C at < 70% relative humidity. Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter. Accuracy: Stated accuracy at 23°C ± 5°C, <70% r ...

  • Omega HHLM-1MV - page 5

    3 ELECTRICAL Photometric Formulas: 10.764·footcandles=lux (lumens/meter 2 ) 0.0929·lux=footcandles (lumens/foot 2 ) Rangescale: DMM to 200.0mV range ¸ 10(20lux), x1(200lux) x10(2000lux), x100(20000lux) x1000(200000lux) Resolution: 0.01lux Spectral response: CIE photopic Acceptance angle: ¦ ¢ 2 <2% cosine corrected (150°) Total accuracy for ...

  • Omega HHLM-1MV - page 6

    4 Temperature Coefficient: 0.1x (specified accuracy)/°C (<18°C or >28°C) OPERATING INSTRUCTIONS Push buttons Range Select Button Press "RANGE" button to select the desired lux range. Each time you press "RANGE" button, the range (and the input range annunciator) incremants, and a new value is displayed. CIE standard ill ...

  • Omega HHLM-1MV - page 7

    5 OPERATION 1. Plug the light transducer test leads into the Vdc input jack and common or ground input jack on the DMM. Observe polarity. 2. Set the DMM to the 200mV range only. 3. Set the light transducer power switch to the desired range (use range button select 20lux, 200lux, 2000lux, 20000lux) or only 200000lux range. 4. Remove the sensor head ...

  • Omega HHLM-1MV - page 8

    SPECIAL CONSIDERATIONS • Keep the plastic domed cosine corrector clean and free of scratches. It may be cleaned with a soft cloth and isopropyl alcohol. • When light is received from many directions simultaneously, take special care to avoid reflections or shadowing the sensor with your body. • For best accuracy, repeat the measurement severa ...

  • Omega HHLM-1MV - page 9

    7 Cleaning Periodically wipe the case with a damp cloth and detergent, do not use abrasives or solvents. CIE Photopic Curve Luminous Efficiency Coefficient Lumen/Watt Conversion Factor Wavelength in Nanometers ...

  • Omega HHLM-1MV - page 10

    8 V l CIE Photopic Photopic Wavelength Luminous Lumen/Watt (nm) Effciency Conversion Coefficient Factor 380 0.0000 0.05 390 0.0001 0.13 400 0.0004 0.27 410 0.0012 0.82 420 0.0040 2.73 430 0.0116 7.91 440 0.0230 15.7 450 0.0380 25.9 460 0.0600 40.9 470 0.0910 62.1 480 0.1390 94.8 490 0.2080 142.0 500 0.3230 220.0 510 0.5030 343.0 520 0.7100 484.0 53 ...

  • Omega HHLM-1MV - page 11

    WARRANTY OMEGA warrants this unit to be free of def ects in materials and workmanship and to give satisfactory ser vice for a period of 13 months from date of purchase. OMEGA W arranty adds an additional one (1) month g race period to the normal one (1) year product warranty to cov er handling and shipping time . This ensures that OMEGA's cust ...

  • Omega HHLM-1MV - page 12

    It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply . OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct b ut OM ...

  • Omega HHLM-1MV - page 13

    Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! HEATERS þ Heating Cable þ Cartridge & Strip Heaters þ Immersion & Band Heaters þ Flexible Heaters þ Laboratory Heaters PRESSURE/STRAIN AND FORCE þ Transducers & Strain Gauges þ Load Cells & Pressure Gauges þ Displacement Transducers þ ...

メーカー Omega カテゴリー Marine Radio

Omega HHLM-1MVのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- HHLM-1MVの取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega HHLM-1MVの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega HHLM-1MVの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega HHLM-1MVの取り付け説明書、サービスマニュアル、簡易説明書、またはOmega HHLM-1MVのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega HHLM-1MVの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega HHLM-1MVデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega HHLM-1MVを使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega HHLM-1MVユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega HHLM-1MVの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega HHLM-1MVの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega HHLM-1MVに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega HHLM-1MVデバイスの基本機能を使うにあたってのヒント。 Omega HHLM-1MVのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega HHLM-1MVに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega HHLM-1MVのメーカー/サービスへの連絡先に関する情報。

Omega HHLM-1MVについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega HHLM-1MVの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega HHLM-1MVで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)