Graco Inc. 800-900の取扱説明書

19ページ 1.02 mb
ダウンロード

ページに移動 of 19

Summary
  • Graco Inc. 800-900 - page 1

    INSTRUCTIONS-PARTS LIST CDRACO This manual wntains IMPORTANT READ AND RETAIN FOR REFERENCE WARNINGS and INSTRUCTIONS HYDRA-CLEAN @ 251 0,3009 Pressure Washers HYDRA-CLEAN" 2510 P/N 800-901, Series A 2500psi (172 bar) OPERATING PRESSURE 2900 psi (200 bar) MAXIMUM WORKING PRESSURE HYDRA-CLEAN" 3009 P/N 800-900, Series A 3000 psi (207 bar) O ...

  • Graco Inc. 800-900 - page 2

    ~A~~~~~ HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read and understand all instruction manuals before operating equipment. FLUlD 1NJECTlON HAZARD General Safety This pressure washer generates very high fluid pressure. Spray from the gun, leaks or tuptured components can inject fluid through your s ...

  • Graco Inc. 800-900 - page 3

    GROUNDING INSTRUCTIONS This product must be grounded. If it should malfunction DANGER -1 or break down, grounding provides a path of least resistance for electric current to reduce the risk of Improper connection of the equipment- grounding electric shock. This equipment is equipped with a cord conductor can result in the risk of electrocution. hav ...

  • Graco Inc. 800-900 - page 4

    HOSE SAFETY High pressure fluid in the hoses can be very dangerous. kind of wear, damage or misuse, the high pressure If the hose develops a leak, split or rupture due to any spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage. ALL FLUID HOSES MUST HAVE STRAIN'REUEFS ON BOTH ENDS. The stra ...

  • Graco Inc. 800-900 - page 5

    INSTALLATION OIL DIPSTICK PUMP LEVEL Figure 1 Check for Shipping Damage Check the unit for any damage that may have occurred in shipping. Notify the carrier Immediately If there Is any damage. Set Up matches the specification in Technical Data (inside Before connecting the unit, be sure the electrical setvice back cover) and the voltage label on th ...

  • Graco Inc. 800-900 - page 6

    Use this procedure whenever starting the pressure washer to help insure that the unit is ready to operate and starting is done safely. 1. Check the oil level. Pump: Add SAE 20 or 30 weight non-detergent oil as necessary. 2. Tum on the water supply. CAUTION Never run the unit dry. Costly damage to the pump will result. Always be sure the water suppl ...

  • Graco Inc. 800-900 - page 7

    Trigger Safety Latch WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, ALWAYS engage the trigger safety moment. latch whenever spraying stops, even for a prevents the gun from being triggered In the engaged position, the trigger safety latch accidentally by hand or If it is dropped ...

  • Graco Inc. 800-900 - page 8

    ~ SHUTDOWN, FLUSHING AND STORAGE WARNING PRESSURE RELIEF PROCEDURE To reduce the risk of serious bodily injury, eyes, or on the skin, always follow this including fluid injection and splashing in the than 10 minutes, when shutting down, and procedure whenever you stop spraying for more before checking or repairing any part of the system. 1. Engage ...

  • Graco Inc. 800-900 - page 9

    TROUBLESHOOTING CHART WARNING io reduce the risk Of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or inlury from moving parts, always follow the Pressure Rellef Procedure Warning before procaeding. PROBLEM ow pressure and/or ump runs rough later leakage from nder pump manifold later in pump requent or remat ...

  • Graco Inc. 800-900 - page 10

    PARTS DRAWING 800-900 Hydra-Clean@ 3009 Pressure Washer 800-901 Hydra-Clean@ 25lO~Pressure Washer 10 308-535 ...

  • Graco Inc. 800-900 - page 11

    ~ ~~~ ~~~ PARTS DRAWING 800-901 Hydra-Cleans 2510 Pressure Washer 800-900 Hydra-Cleans 3009 Pressure Washer REF NO. 2 1 3 4 5 6 7 8 9 10 11 12 14 13 15 16 17 18 19 PART NO. DESCRIPTION 800-643 CHASSIS 803-788 BELT GUARD 801-941 SCREW, Cap, hex hd., 5/16-18 x 1 100-214 WASHER; Lock, 5/16 100-023 WASHER, Flat, 5/16 801-817 MOTOR, 20 hp. TEFC. . 3 pha ...

  • Graco Inc. 800-900 - page 12

    PARTS DRAWING 801-790 Pump Assem 20 13 16 4i 12 308-535 ...

  • Graco Inc. 800-900 - page 13

    PARTS LIST 801-790 Pump Assembly, 2500 psi REF PART NO. NO. DESCRIPTION REF PART QTY NO. NO. DESCRIPTION 1 801.-781 MANIFOLD 3 801-469 WASHER, Lock 2 801-468 SCREW, Cap, hex hd 16 ' 33 803-283 SCREW, Cap, socket hd 5 Kit 1 6 Kit 1 SEAT, Valve 36 803-415 CRANKSHAFT 7 Kit 1 SPRING, Valve PLATE, Valve 37 803-426 RING, Connecting rod 8 Kit 1 GUIDE ...

  • Graco Inc. 800-900 - page 14

    PARTS DRAWING 803-814 Pump Assem 20 41 14 308-535 ...

  • Graco Inc. 800-900 - page 15

    PARTS LIST 803-814 Pump . -... 801-781 MANIFOLD NO. DESCRIPTION 3 2 4 5 6 7 8 9 10 12 11 13 14 16 15 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 801-468 SCREW, Cap, hex hd ~ ~ ~~~ ~- 801-469 WASHER. Lock Kit 1 Kit 1 O-RING ~' ~ SEAT. Valve Kit 1 PLATE, valve Kit 1 SPRING. Valve Kit 1 Kit 1 GUIDE, valve VALVE ASSEMBLY Kit 4 O-RING Kit 4 CAP 80 ...

  • Graco Inc. 800-900 - page 16

    PUMP SERVICE WARNING To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, always follow the Pressure Relief Procedure Warnlng before proceeding. 1 NOTE: The following metric wrenches are needed: Refer to the individual repair sections and the M10, Mi3 and M30. Rep ...

  • Graco Inc. 800-900 - page 17

    Servicing the V-Packings NOTE: There are two types of packing kits: one is packings only, the other includes the packings, rings and retainers. 1. Remove the manifold as outlined in the Pumping Section. 2. Carefully pull the packing retainer from the manifold. Examine the O-ring and replace it if it is cut or damaged. 3. Remove the v-packing and he ...

  • Graco Inc. 800-900 - page 18

    TECHNICAL DATA Motor (totally enclosed fan cooled) Electrical Se~i~e Water Pump Maximum Working Pressure Water Pumo Maximum Flow Dimensions Width Length Height Maximum Inlet Water Temperature wetted parts High Pressure Hose Pressure Washer (including fittings) Bypass Model 800-901 Model 800-900 20 HP, 3 phase 2% voIff50 amp/3 phase or 20 HP, 3 phas ...

  • Graco Inc. 800-900 - page 19

    THE GRACO WARRANTY WARRANTY AND DISCLAIMERS and workmanship on the date of sale by an authorized Graw distributor to the original purchaSErfor Use. Graoawarmntsallequipmentmanufactursdby~andbearingitsnametobefreefmmdefectslnmaterial Aspurohaser'ssolemmedyforbreachofthiswarranty,Gramwill,foraperiodoltwentyfourmonthsfmm dateofsale,repairorrepiac ...

メーカー Graco Inc. カテゴリー Pressure Washer

Graco Inc. 800-900のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 800-900の取扱説明書
- Graco Inc.の製品カード
- パンフレット
- またはGraco Inc. 800-900の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco Inc. 800-900の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco Inc. 800-900の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco Inc. 800-900のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco Inc. 800-900の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco Inc. 800-900デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco Inc. 800-900を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco Inc. 800-900ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Graco Inc.の取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco Inc. 800-900の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco Inc. 800-900の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco Inc. 800-900に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco Inc. 800-900デバイスの基本機能を使うにあたってのヒント。 Graco Inc. 800-900のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco Inc. 800-900に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco Inc. 800-900のメーカー/サービスへの連絡先に関する情報。

Graco Inc. 800-900についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco Inc. 800-900の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco Inc. 800-900で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)