  • Harbor Freight Tools 90234 - page 1

    COMPRESSOR 4 HP - 10 GALLON Model 90234 OPERA TING INSTR UCTIONS 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our W eb site at: http://www .harborfreight.com Cop yr ight 2003 by Harbor F reight T ools ® . All rights reser v ed. No por tion of this manual or any ar tw or k contained herein ma y be reproduced in any shape or form without the ...

  • Harbor Freight Tools 90234 - page 2

    PR ODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this manual f or the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures, parts list and as- sembl y diagram. Keep your in voice with this man ual. Write the in voice number on the inside of the front co ver . K eep this manual and in voice ...

  • Harbor Freight Tools 90234 - page 3

    3. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control. Protect others in the work area from debris such as chips and sparks. Provide barriers or shields as needed. ELECTRICAL SAFETY 4. Grounded tools must be plugged into an outlet properly installed and grounded in accordance with a ...

  • Harbor Freight Tools 90234 - page 4

    10. Dress properl y . Do not wear loose clothing or je welry . Contain long hair . K eep your hair , clothing, and gloves a way fr om mo ving par ts. Loose clothes, je welr y , or long hair can be caught in mo ving par ts. 11. A v oid accidental star ting. Be sure the P ower Switch is off bef ore plugging in. Carrying power tools with your finger o ...

  • Harbor Freight Tools 90234 - page 5

    the tool serviced before using. Many accidents are caused by poorly maintained tools. 21. Use only accessories that are recommended by the manufacturer for your model. Accessor ies that may be suitab le for one tool ma y become hazardous when used on another tool. SER VICE 22. T ool ser vice must be perf ormed onl y by qualified repair per sonnel. ...

  • Harbor Freight Tools 90234 - page 6

    3. Y our tool must be plugged into an appropriate outlet, proper ly installed and grounded in accordance with all codes and ordinances . The plug and outlet should look like those in the f ollowing illustration. (See Figure A.) FIGURE A SKU 90234 P A GE 6 DOUBLE INSULA TED T OOLS: T OOLS WITH TW O PR ONG PLUGS 4. T ools mar ked “Double Insulated? ...

  • Harbor Freight Tools 90234 - page 7

    SKU 90234 P A GE 7 SYMBOLOGY V ~ A xxxx/min. Double Insulated Canadian Standards Association Underwriters Laboratories, Inc. V olts Alternating Current Amperes No Load Revolutions per Minute (RPM) no SPECIFIC SAFETY RULES 1. Maintain a safe working environment. Keep the work area well lit. Make sure there is adequate surrounding workspace. Alwa ys ...

  • Harbor Freight Tools 90234 - page 8

    SKU 90234 P AGE 8 8. When checking the oil level, make sure to unscrew (do not pull) the Oil Plug (part #78) out. 9. Drain the Air Compressor’ s T ank (par t #50) every da y . Do not allow moisture to build up inside the T ank. Do not open the T ank Drain V alve (par t #59) so that more than four threads are showing. 10. A v oid injur y . Ne ver ...

  • Harbor Freight Tools 90234 - page 9

    22. W ARNING! P eople with pacemakers should consult their ph ysician(s) before using this product. Operation of electrical equipment in close proximity to a hear t pacemak er could cause interf erence or f ailure of the pacemaker . 23. W ARNING! The warnings, precautions, and instructions discussed in this manual cannot cov er all possible conditi ...

  • Harbor Freight Tools 90234 - page 10

    30-weight, non-detergent, compressor oil before each use. Running the Air Compressor with no oil or low oil will cause damage to the equipment and v oid the warranty . T o check the le vel of oil, mak e sure the Air Compressor is OFF . Then, obser ve the Oil Le v el Window (par t #72). The lev el of oil should just reach the horizontal line as show ...

  • Harbor Freight Tools 90234 - page 11

    SKU 90234 P A GE 11 4. Make sure the “On/Off ” Pressure Switch (par t #66) is DO WN in its OFF position. Then, plug the Power Cord (part #64) into the nearest 120 volt, grounded, electrical outlet. (See Figure F .) 5. Pull UP on the “On/Off ” Pressure Switch (par t #66) to its ON position. (See Figure F .) AIR OUTLET V AL VE (#69) AIR HOSE ...

  • Harbor Freight Tools 90234 - page 12

    8. T ur n the Pressure Regulator (par t #70) counterclockwise to increase the amount of compressed air to the air tool being used (from 90 PSI to 115 PSI). T ur n the Pressure Regulator clockwise to decrease the amount of compressed air . (See Figure F .) 9. NO TE: If it is necessar y to quic kly depressurize the Air Compressor , tur n off the Air ...

  • Harbor Freight Tools 90234 - page 13

    SKU 90234 P A GE 13 4. Daily: Purge the T ank (par t #50) daily of all air and moisture to pre vent corro- sion. T o do so , unscrew the T ank Drain V alve (par t #59) two to three tur ns. Do not unscrew the T ank Drain V alve more than three turns. When all the air pressure and moisture is released from the T ank, retighten the T ank Drain V alve ...

  • Harbor Freight Tools 90234 - page 14

    P ARTS LIST SKU 90234 P A GE 14 # t r a Pn o i t p i r c s e D. y t Q# t r a Pn o i t p i r c s e D. y t Q 1t l o B4 5 2r e h s a W2 2d a e H r e d n i l y C1 6 2l a n i m r e T7 3r e h s a W r e v o C r e d n i l y C1 7 2d n a B n o l y N2 A 4t l o B2 9 2t l o B4 B 4r e c a p S e t a l P e v l a V t s u a h x E1 0 3r e d l o H2 C 4e t a l P e v l ...

  • Harbor Freight Tools 90234 - page 15

    SKU 90234 P A GE 15 P AR TS LIST (CONTINUED) # t r a Pn o i t p i r c s e D. y t Q# t r a Pn o i t p i r c s e D. y t Q B 3 5r e v o C l e e h W k n a T2 8 6e l p p i N1 4 5t f a h S n I g n i R g n i n i a t e R2 9 6e v l a V t e l t u O r i A1 5 5w o b l E t s u a h x E1 0 7r o t a l u g e R e r u s s e r P1 6 5. y s s A e b u T r e p p o C t s u ...

  • Harbor Freight Tools 90234 - page 16

    SKU 90234 P A GE 16 ASSEMBL Y DIA GRAM NO TE: Some par ts are listed and shown f or illustration pur poses only , and are not av ailable individually as replacement parts. ...

メーカー Harbor Freight Tools カテゴリー Air Compressor

Harbor Freight Tools 90234のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 90234の取扱説明書
- Harbor Freight Toolsの製品カード
- パンフレット
- またはHarbor Freight Tools 90234の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Harbor Freight Tools 90234の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Harbor Freight Tools 90234の取り付け説明書、サービスマニュアル、簡易説明書、またはHarbor Freight Tools 90234のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Harbor Freight Tools 90234の製品を使用するにあたって最も人気のある説明書を閲覧できます。

Harbor Freight Tools 90234デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHarbor Freight Tools 90234を使用するのを助ける技術的文書のことです。説明書は通常、全てのHarbor Freight Tools 90234ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Harbor Freight Toolsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Harbor Freight Tools 90234の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHarbor Freight Tools 90234の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Harbor Freight Tools 90234に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Harbor Freight Tools 90234デバイスの基本機能を使うにあたってのヒント。 Harbor Freight Tools 90234のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Harbor Freight Tools 90234に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHarbor Freight Tools 90234のメーカー/サービスへの連絡先に関する情報。

Harbor Freight Tools 90234についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHarbor Freight Tools 90234の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHarbor Freight Tools 90234で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)