T ABLE OF C ONTENTS 1. BEFORE YOU BEGIN ....................................................................................................................................................... 3 W HAT I S I NCLUDED ........................................................................................................................................ ...
-
Chauvet INTIMIDATORSCANLED300 - page 3
Page 3 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) 1. B EFORE Y OU B EGIN What Is I ncluded • 1 x Intimidator™ Sc an LED 300 • 1 x Pow er Cor d • 1 x Warranty Card • 1 x User Manual Unpacking Inst ructions Immediately upon receiving a fi xture, carefully unpack the carton, check the contents to ensure that all parts are present, ...
-
Chauvet INTIMIDATORSCANLED300 - page 4
Page 4 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) Safety Instructi ons • Please keep this User Manual for f uture consultation. If you sell the unit to another user, be sure that they also receiv e this instruction booklet. • Always make sure that you are co nnecting to the proper voltage, an d that the line voltage you are connecting ...
-
Chauvet INTIMIDATORSCANLED300 - page 5
Page 5 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) 2. I NTRODUCTION Product Dimensio ns ...
-
Chauvet INTIMIDATORSCANLED300 - page 6
Page 6 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) Product Overview Bracket Adjustment Knob DMX In DMX Out Power Out Fuseholder Power In Voltage Selection Switch (115/230 VAC) Safety ...
-
Chauvet INTIMIDATORSCANLED300 - page 7
Page 7 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) 3. S ETUP AC Power This fixture is switchable and runs on either 115 VA C, 60 Hz or 230 VAC, 50 Hz po wer. Before powering on the unit, make s ure the line voltage to which you are c onnecting it matches the current setting on the voltage selec tion switch. To determine the power requirem ...
-
Chauvet INTIMIDATORSCANLED300 - page 8
Page 8 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) Mounting Orientation The Intimidator™ Scan LED 300 may be mounted in any positi on provided there is adequate room for ventilation. Rigging Be sure that the structure can sup port the weight of the fixture. Please s ee the “Technical Specifications” section of this manual for a detai ...
-
Chauvet INTIMIDATORSCANLED300 - page 9
Page 9 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) 4. O PERATING I NSTRUCTIONS Using the Contro l Panel Access control panel functions using the four buttons l ocated directly underneath the LED dis play on the included wired remote. B UTTON F UNCTION < MODE ESC> Used to scroll through the current operating mode, as well as bac k out ...
-
Chauvet INTIMIDATORSCANLED300 - page 10
Page 10 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) Operation DMX Operation This is the operating mode which will allow for control with an e xternal DMX controller. You must set the starting address for this mode. If thi s is your first time using DMX, then i t is recommended that you refer to the “DMX Prime r” section in the “Appen ...
-
Chauvet INTIMIDATORSCANLED300 - page 11
Page 11 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) Sound - Active This fixture has a preprogrammed, sound triggered chase. Access this via the control panel on the front of the fixture. Please see the chart below for further explanation. 1. Press <MODE/ESC> until one of the standalone modes appears on the LED screen ( SL Av, NS tS , ...
-
Chauvet INTIMIDATORSCANLED300 - page 12
Page 12 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) DMX Channel Va lues 11 - CH Mode C HANNEL V ALUE F UNCTION C HANNEL V ALUE F UNCTION 1 000 255 Pan 0°~180° 7 000 015 016 127 128 239 240 255 Gobo Rotation Stop Rotate Counter - clockw ise (sl ow fast) Rotate Clockwise (slow fast) Gobo bounce 2 000 255 Til ...
-
Chauvet INTIMIDATORSCANLED300 - page 13
Page 13 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) 7- CH Mode C HANNEL V ALUE F UNCTION C HANNEL V ALUE F UNCTION 1 000 255 Pan 0°~180° 6 000 015 016 127 128 239 240 255 Gobo Rotation Stop Rotate Counter - clockw ise (sl ow fast) Rotate Clockwise (slow fast) Gobo bounce 2 000 255 Tilt 0°~90° 3 000 0 ...
-
Chauvet INTIMIDATORSCANLED300 - page 14
Page 14 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) 5. A PPENDIX General Troubl e shooting S YMPTOM P OSSIBLE C AUS E ( S ) P OSSIBLE A CTION ( S ) Breaker/Fuse keeps blowing Excessive circuit load Check total load placed on the electrical circuit. Short circuit along the power wires Check for a short in the el ectrical wiring (internal an ...
-
Chauvet INTIMIDATORSCANLED300 - page 15
Page 15 of 17 Intimidator Scan LED 300 User M anual (Rev. 3) General Mainten ance To maintain optimum performanc e and minimize wear, fixtures s hould be cleaned frequentl y. Usage and environment are contr ibuting factors in determining frequenc y. As a general rule, fixtures should be cleaned at leas t twice a month. Dust build up red uces light ...
-
Chauvet INTIMIDATORSCANLED300 - page 16
T ECHNICAL S PECIFICATIONS WEIGHT & DIMENSIONS Length .............................................................................................................. 11 in (279 mm) Width ................................................................................................................ 10 in (254 mm) Height ......................... ...
-
Chauvet INTIMIDATORSCANLED300 - page 17
C ONTACT U S World Wi de General Informa tion CHAUVET® 5200 NW 108 th Ave Sunrise, FL 33351 voice: 954.929.1115 fax: 954.929.5560 toll free: 800.762.1084 Technical Support CHAUVET® 5200 NW 108 th Ave Sunrise, FL 33351 voice: 954.929.1115 (Press 4) fax: 954.929.5560 (Attentio n: Service) World Wide We b www.chauvetlighting.com ...
Chauvet INTIMIDATORSCANLED300についてご質問がありますか?
次のフォームを使用してください
見つけた説明書を読んでもChauvet INTIMIDATORSCANLED300の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがChauvet INTIMIDATORSCANLED300で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。