Waterpik Technologies LGの取扱説明書

28ページ 1.14 mb
ダウンロード

ページに移動 of 28

Summary
  • Waterpik Technologies LG - page 1

    FOR YOUR SAFETY - This product must be installed and serviced by a profes- sional service technician, qualified in pool heater installation. Improper installa- tion and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warrant ...

  • Waterpik Technologies LG - page 2

    T ABLE OF CONTENTS SECTION 1. General Information 1A. Introduction ................................................... 1 1B. Description ................................................... 2 1C. Warranty ....................................................... 2 1D. Technical Assistance .................................... 2 SECTION 2. Installation ...

  • Waterpik Technologies LG - page 3

    Model LG & LD Pool and Spa Heater Page 1 SECTION 1. General Information 1A. Introduction This manual provides installation and operation instructions for the Laars Lite 2, Model LG and LD pool and spa heaters. Read these installation and operation instructions completely before proceeding Figure 1. General Configuration. with the installation. ...

  • Waterpik Technologies LG - page 4

    Page 2 WATERPIK TECHNOLOGIES INC. Gas-Fired Pool Heaters, ANSI Z21.56, and in Canada with CAN1-4.7-M85. Certain sections of this manual are specific to either United States or Canadian installations, and are labeled as such. 1B. Description The Laars Lite 2 LD heater gets electrical power from an external 120VAC or 240VAC source and provides a dual ...

  • Waterpik Technologies LG - page 5

    Model LG & LD Pool and Spa Heater Page 3 Notes: 1. An Underwriters' Laboratories listed vent cap is required to prevent downdraft and allow the heater to function properly and safely. 2. Use approved roof jack. When a drafthood is used, it must be connected to a vent pipe which stops at least 2 feet (0.61 meters [m]) above the highest poin ...

  • Waterpik Technologies LG - page 6

    Page 4 WATERPIK TECHNOLOGIES INC. Locate the heater in an open, unroofed area . Do not install the heater under a deck. Do not locate the heater below or adjacent to any doors, glass openings, louvers, grills, etc., which connect in any way with an inhabited area of a building, even though the access might be through another structure (e.g., a gara ...

  • Waterpik Technologies LG - page 7

    Model LG & LD Pool and Spa Heater Page 5 without modification and in accordance with all local, state, provincial and national codes. Proper ventilation of exhaust and combustion air are essential for the safe operation of the heater. 2D. Combustion and Ventilation Air Supply All indoor installations must have openings to outside air for combus ...

  • Waterpik Technologies LG - page 8

    Page 6 WATERPIK TECHNOLOGIES INC. 7. Disconnect the heater and its individual shutoff valve from the gas supply system during pressure testing of the system at pressures higher than 1/2 pounds per square inch (psi) (3.45 kilopascals [kPa]). If the test pressure is equal to or less than 1/2 psi (3.45 kPa), close the manual shutoff valve on the heate ...

  • Waterpik Technologies LG - page 9

    Model LG & LD Pool and Spa Heater Page 7 IG N /1 20 IG N /2 40 (LI) (L2) IG N TH VALV E GND REMOT E CONNECTOR SP A POOL OFF WA T E R TEM P SEN SOR PR ESSU RE SW IT CH LIMI T LIMIT FI REMAN SWITC H CONNECTION FUSI BLE LINK EL EC. FUSE MV1 MV2 HONEYWE LL GAS V AL VE BR IGNITION CONTROL (FENW AL) 0533 BK Y/ B K BK R W W W Y Y CIRCUIT IGNI TOR IGNI ...

  • Waterpik Technologies LG - page 10

    Page 8 WATERPIK TECHNOLOGIES INC. Figure 7. LG Connection/Schematic Wiring Diagram 2F-2. Auxiliary Time Clock Wiri ng (LD) If you install a time clock to control the filter pump operation, it is recommended that the time clock have its own low voltage (Firemans) switch to turn off the heater before turning off the pump. The switch should shut of ...

  • Waterpik Technologies LG - page 11

    Model LG & LD Pool and Spa Heater Page 9 Figure 8. Field Wiring Connections (LD). Figure 9. Time Clock Wiring. To install a time clock auxiliary switch into the heater wires (see Figure 9): 1. Remove heater door. 2. Remove the factory installed wire between terminals 1 and 2 on the terminal strip (see Figure 9). 3. Connect the wires from the ti ...

  • Waterpik Technologies LG - page 12

    Page 10 WATERPIK TECHNOLOGIES INC. 2G-2. Reversible Water Connections Waterpik Laars ships the Laars Lite 2 heater with the water connections on the right side. The Laars Lite 2 heater can be installed with the water connections on either side. It could be necessary, or helpful, to switch the connections to the left side to improve access for insta ...

  • Waterpik Technologies LG - page 13

    Model LG & LD Pool and Spa Heater Page 11 1. Remove heater door. 2. If there is a vent cap or drafthood (indoor) on top of the heater, remove it. 3. Remove all 8 hex-head screws fastening the top and lift the top assembly straight up (see Figure 12). 4. Remove rainshield assembly and set it aside. 5. Remove screws that fasten the gap closures t ...

  • Waterpik Technologies LG - page 14

    Page 12 WATERPIK TECHNOLOGIES INC. 20. Connect the white wire labeled PS to the pressure switch and the other white wire to its original location on the Fireman's switch. 21. Reinstall the drain plugs and tighten securely. Replace jacket/plug grommets. 22. Install the flue collector assembly. Be sure the front and rear panels of the flue colle ...

  • Waterpik Technologies LG - page 15

    Model LG & LD Pool and Spa Heater Page 13  When chemical feeders are used, plumb the feeder downstream of the heater and install an in- line check valve between the heater and the feeder (a minimum of 18" is required between the heater and the check valve).  Never deposit chemicals directly in the pool skimmer. 2G-4a. Water Chemistry ...

  • Waterpik Technologies LG - page 16

    Page 14 WATERPIK TECHNOLOGIES INC. 2G-7. Automatic Flow Control Valve The automatic flow control valve maintains the proper flow through the heater at rates up to approxi- mately 125 Gallons Per Minute (GPM) (474 liters per minute [LPM]). If the system filter-flow rate is higher than approximately 125 GPM (474 LPM), install a manual bypass valve (s ...

  • Waterpik Technologies LG - page 17

    Model LG & LD Pool and Spa Heater Page 15 Note: When using metal pipe as heat sink, join metal and PVC/CPVC, using metal male and PVC/CPVC female connection. Figure 20. Typical installation. 11. If the temperature rise is below the minimum range indicated, two possibilities arise: a . The supply gas volume is too low. b. The system's water ...

  • Waterpik Technologies LG - page 18

    Page 16 WATERPIK TECHNOLOGIES INC. 9. Once the temperature is within the correct range, safety wire the handle of the manual bypass valve in place and tag the valve to prevent change in the water flow. SECTION 3. Operating Instructions 3A. General Information With any new pool or spa installation, operate the filter pump with the heater off long en ...

  • Waterpik Technologies LG - page 19

    Model LG & LD Pool and Spa Heater Page 17 W ARNING: If you do not follow these instructions exactly , a fire or explosion may result, causing property damage, personal injury or loss of life.  If you cannot reach your gas supplier , call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If t ...

  • Waterpik Technologies LG - page 20

    Page 18 WATERPIK TECHNOLOGIES INC. 3B-2. Model LG (Standing Pilot) 1. STOP! Read the safety information above. 2. Set the thermostat to lowest setting and turn appliance ON/OFF switch to "OFF". 3. Turn gas control knob clockwise until it stops at "OFF" position. 4. Wait five (5) minutes to clear out any gas. If you then smell ga ...

  • Waterpik Technologies LG - page 21

    Model LG & LD Pool and Spa Heater Page 19 6. Use compressed air to blow out any standing water remaining in the heat exchanger. 7. Grease the threads on the drain plugs and rein- stall plugs, but do not tighten. 8. Disconnect the pressure switch from the siphon loop (copper tubing) (see Figure 22). 3D-3. Spring Start-up To restart the heater in ...

  • Waterpik Technologies LG - page 22

    Page 20 WATERPIK TECHNOLOGIES INC. 3E. Water Chemistry For notes on water chemistry please consult sections 2G-4, 2G-4a and Table 7 on page 13 of this manual. 3F. Spa/Hot Tub Safety Rules WARNING The following Safety Rules for Hot Tubs, recommended by the U.S. Consumer Product Safety Commission, should be observed when using the spa. 1. Spa o ...

  • Waterpik Technologies LG - page 23

    Model LG & LD Pool and Spa Heater Page 21 3H. Periodic Inspection 3H-1. Owner Inspection Waterpik Laars designs and constructs the Laars Lite 2 heater to provide long performance life when installed and operated properly under normal condi- tions. The following basic guidelines are suggested for your inspection: 1. Keep the top and surrounding ...

  • Waterpik Technologies LG - page 24

    Page 22 WATERPIK TECHNOLOGIES INC. Key Model ORDER No D escription No PART NO PILOT/IGNITER SYSTEM 1 Pilot, Main Burner Assembly, NAT All R0099100 1 Pilot, Main Burner Assemby, LPG All R0099200 2 Pilot Burner, NAT All R0096700 2 Pilot Burner, LPG All R0096600 3 Pilot Electrode All W0040000 4 Pilot Generator All W0036901 5 Ceramic Insulator Assem bl ...

  • Waterpik Technologies LG - page 25

    Model LG & LD Pool and Spa Heater Page 23 64 63 67 9 10 11 BURNER TRAY (LD SHOWN) SEE NEXT PAGE FOR DETAIL 50 51 52 53 54 66 60 59 61 62 65 UNITED STATES CANADA UNITED STATES CANADA UNITED STATES 82 82 85 85 101 102 103 104 105 106 107 108 HEAT EXCHANGER SEE NEXT PAGE FOR DETAIL TEMPERATURE CONTR0L SEE NEXT PAGE FOR DETAIL ...

  • Waterpik Technologies LG - page 26

    Page 24 WATERPIK TECHNOLOGIES INC. 33 17 15 7 6 14 8 5 2 1 4 34 16 18 70 98 96 97 75 72 75 74 38 32 95 86 85 49 48 69 47 44 45 80 77 79 78,81 90 93 88 94 91 39 30 31 43 76 87 23 22 36 28 34 26 33 25 (LD SHOWN) 29 27 35 3 12 (LG SHOWN) 19 24 13 20 (LG SHOWN) 40 42 41 69 72 73 74 71 73 84 89 92 68 ...

  • Waterpik Technologies LG - page 27

    Model LG & LD Pool and Spa Heater Page 25 NOTES ...

  • Waterpik Technologies LG - page 28

    LIMITED W ARRANTY Tha nk you for pur cha sin g Jand y ® p ool and spa pro duc ts. W at er p ik T ech nol ogi es ( manu factur er o f Jan dy products, including Laars ® pool and spa heaters) w arrants all par ts to be free from manufacturing def ects in mater ials and wor kmans hip for a per iod of o ne year from the dat e of reta il purc hase, wi ...

メーカー Waterpik Technologies カテゴリー Swimming Pool Heater

Waterpik Technologies LGのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- LGの取扱説明書
- Waterpik Technologiesの製品カード
- パンフレット
- またはWaterpik Technologies LGの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Waterpik Technologies LGの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Waterpik Technologies LGの取り付け説明書、サービスマニュアル、簡易説明書、またはWaterpik Technologies LGのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Waterpik Technologies LGの製品を使用するにあたって最も人気のある説明書を閲覧できます。

Waterpik Technologies LGデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWaterpik Technologies LGを使用するのを助ける技術的文書のことです。説明書は通常、全てのWaterpik Technologies LGユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Waterpik Technologiesの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Waterpik Technologies LGの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWaterpik Technologies LGの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Waterpik Technologies LGに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Waterpik Technologies LGデバイスの基本機能を使うにあたってのヒント。 Waterpik Technologies LGのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Waterpik Technologies LGに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWaterpik Technologies LGのメーカー/サービスへの連絡先に関する情報。

Waterpik Technologies LGについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWaterpik Technologies LGの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWaterpik Technologies LGで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください