    Doc. No.IZ*-OMK0015 - B OPERA TION MANUAL PRODUCT NAME : Ionizer MODEL: IZS31 Series ○ Read this operation manual carefully to understand before inst allation and operation. ○ Pay extra attention on the clause concerning the safety . ○ Keep this operation manua l available whenever necessar y . ...

  • SMC Networks IZS31 - page 2

    1 INDEX 1.Sefety instructions ・ ・ ・ ・ ・・・・・・・ ・ ・・・・・・・・・・・・・・・ ・・ ・・ ・・・ 2 2.Installation ・・・・・・・・・・・・・・・ ・・ ・・・・・・・・・ ・・ ・ ・ ・・ ・ ・ ・ ・・・ 6 2-1.Installation of Ionizer body ・・・・・・・・・・? ...

  • SMC Networks IZS31 - page 3

    2 1. Safety instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard by labeling "Caution" , "W arning" , and "Danger" . T o ensure safety , be sure to observe ISO4414, JIS B8370and other safety precautions. CA ...

  • SMC Networks IZS31 - page 4

    3 WARNING 1. This product is intended to be used for the general F A device s. If other applications (especially the ones indicated in 4 on page 2) are used, please contact SMC before the use. 2. Use under specified vo ltage and temperature. Voltage out of specific ation may cause malfunction, break age, electric shock and fire. 3. Use clean compre ...

  • SMC Networks IZS31 - page 5

    4 5. Do not touch electrode needle with finger or metal tool directly. It may cause injury. If electrode needle or cartridge is it ma y stick to the fingers, damaged by tools, it will not only interfere the specification function and performance but also may cause operation failure or accident. 6.Do not attach tape or seal on the product body. If c ...

  • SMC Networks IZS31 - page 6

    5 9. Be sure there is no incorrect wiring before oper ation. Incorrect wiring ma y cause product breakage or malfunction. 10. Flush pneumatic pipi ng before its installation. Make sure that all dust, water droplet, oil etc. are eliminated before piping. WARNING 1. Use within operating fluid and ambient temperature range. Operating fluid and ambient ...

  • SMC Networks IZS31 - page 7

    6 accident. 3. Do not open the case to disa ssemble and reconstruct the product. It may cause electric shock, operation failure and disast er such as fire. In addition, note the product, which is disassembled or reconstructed, may not satisfy the functions and per formance in the specifications and is out of guarantee. 4. Do not operate the product ...

  • SMC Networks IZS31 - page 8

    7 3. Mount intermediate brackets on the ionizer body at regular interval. 4. Tap M5 thread on the brackets m ounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. 5. Adjust angle of the ionizer body to ensure proper static charge e liminat ion, and fix it with detent threads (M5) of brackets. Intermediat ...

  • SMC Networks IZS31 - page 9

    8 6. Be sure to ground the DC1 (-) lead wire [blue] of the power supply cable (R esistance between the lead wire and the earth ground should be 100 Ω or less.) If the lead wire is not gr ounded, the ion balance will be unstable, and an electric shock may occur . At the same time, the ionizer and power supply might be damaged. 2-2. Installation of ...

  • SMC Networks IZS31 - page 10

    9  Auto balance sensor Horizontally place the aut o balance sensor under the ionizer and face its metal plate upward. Because the ion balance will be changed depending on the installati on height, install the sensor on the same le vel with a workpiece as much as po ssible. The auto balance sensor c an be removed once the ion balance adjustment i ...

  • SMC Networks IZS31 - page 11

    1 0 2. Connect the lead wires in acco rdance with the lead wire list. (See Chapter 4) Arrange lead wires in a ccordance with the wiring table. The unused wires should be cut short or covered with vinyl tape without pealing the coat to prevent them from coming contact with other wires. 3. When the feed back sensor or aut o balance sensor is used, re ...

  • SMC Networks IZS31 - page 12

    11 3. DC mode Plasma ions or minus ions are continuously discharged. The parts ot her than the charged object need to be grounded to prevent them from being charged. The plasma and minus ions cannot be discharged simultaneously. 3-2. Detection of the dirt on the electrode needle When the maintenance start-up signal is input, the i onizer detects if ...

  • SMC Networks IZS31 - page 13

    1 2 4. Selection and setting of equipment 4- 1. Sensing DC mode 1. Selection of bar length ・ Select the length applicable to work size base on static charge elimination area and st atic charge elimination characteristics. 2. Installation of body ・ Keep the distance between the ioni zer and charged objects within 200 to 2000mm. Although ...

  • SMC Networks IZS31 - page 14

    1 3 6. Wiring of the power supply cable ・ Connect dedicated pow er supply cables.  Connection with the power supply for ionizer operat ion Symbol Cable color Cable name Connection Description DC1 ( + ) Brown Power supply DC24V ○ DC1 ( - ) Blue Power supply GND[FG] ○ Power supply cable for ionizer operation OUT4 Dark Green Sensor mo ...

  • SMC Networks IZS31 - page 15

    1 4 8. LED display  POWER LED ・・・ The power supply input and the connection of the sens ors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong po wer supply is applied. ) POWER SNSR Lights up when the feed back sensor is connected.(Green)  ION LED ・・・ The charged condit ...

  • SMC Networks IZS31 - page 16

    1 5 9. Alarm T ype of alarm Description How to reset Abnormal high voltage Notifies when overcurrent such as high voltage leakage occurs. The ion-discharge-output is stopped, HV ALRM sets of f and output the signal for failure. Tu rn of f the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the ...

  • SMC Networks IZS31 - page 17

    1 6 4-2. Pulse DC mode 1. Selection of the bar length ・ Select an appropriate length that is suitable for the work size, static charge elimination characteristics and static charge elimination range. 2. Installation of the ionizer ・ Keep the distance between the ionizer and charged object within 50 to 2000mm. When the auto balance sensor is use ...

  • SMC Networks IZS31 - page 18

    1 7 5. Setting of the frequency selecting switch ・ Select the ion-production frequency . Ion-production frequency Switch setting 1Hz 0 3Hz 1 5Hz 2 10H z 3 15Hz 4 20Hz 5 30Hz 6 60Hz 7 6. Wiring of the pow er supply cables ・ Connect a dedicated power supply cable.  Connection power supply for ionizer drive No Lead wire color Description Dire ...

  • SMC Networks IZS31 - page 19

    1 8 8. LED display  POWER LED ・・・ The power supply input and the connecti on of the sensors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong po wer suppl y is appli ed. ) POWER SNSR Lights up when the auto balance sensor is connected.(Green)  ION LED ・・・ The discharge ...

  • SMC Networks IZS31 - page 20

    1 9 9. Alarm T ype of alarm Description How to reset Abnormal high voltage Notifies when overcurr ent such as high voltage leakage occurs.T he ion-discharge-output is stopped, HV ALRM sets of f and output the signal for failure. T urn off the power supply to solve the problem. Once it’s solved, apply the power supply again. Or turn on and off the ...

  • SMC Networks IZS31 - page 21

    2 0 4-3 . DC mode 1. Selection of bar length ・ Select the length applicable to work size base on static charge elimination area and st atic charge elimination characteristics. 2. Installation of body ・ Keep the distance between the ioni zer and charged objects within 50 to 2000mm. Although the ionizer can be mounted outside of this range, it ...

  • SMC Networks IZS31 - page 22

    21 6. LED display  POWER LED ・・・ The power supply input and the connection of the sens ors are displayed. LED name Functions MAIN Lights up when the power supply is applied. (Green) (Flashes when wrong po wer suppl y is appli ed. ) POWER SNSR Goes out.  ION LED ・・・ The discharged ion polarity is displayed. LED name Functions + ...

  • SMC Networks IZS31 - page 23

    2 2 4-4. Power supply cable connection circuit ■ NPN Note) Because the s ensor monitor output ( OUT4 : Dark Green ) is not insulated from the internal circuit of the ionizer, It is ground ed. (It is connected to FG). ...

  • SMC Networks IZS31 - page 24

    2 3 ■ PNP Note) Because the sensor monitor output ( OUT4 : Dark Green ) is not insulated from the internal circuit of the ionizer, It is ground ed. (It is connected to FG). ...

  • SMC Networks IZS31 - page 25

    2 4 5. Specifications 5-1 . Ionizer Ionizer model IZS31(NPN) IZS31P(PNP) Type Corona discharge Voltage supply method Sensing DC , pulse DC, Plus DC, Minus DC Discharge output +/- 7000 V Ion balance *1 +/-30V (For Stainless electrode needle, from -10 0 to +100V) Fluid Air (Clean dry air) Op. pressure ( ...

  • SMC Networks IZS31 - page 26

    2 5 5-2 . Sensor Sensor model IZS31-DF (Feed back sensor) IZS31-DG (Auto-balance sensor) Operating ambient temp 0 to 50 ℃ Operating ambient humidity 35 to 80%Rh(No dew condensation) Case material ABS ABS, Stainless Vibration resistance Endurance 50H z, Amplitude 1mm, 2hours each for XY Z Impact resistance 10G Weight 200g(including c ...

メーカー SMC Networks カテゴリー Air Cleaner

SMC Networks IZS31のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- IZS31の取扱説明書
- SMC Networksの製品カード
- パンフレット
- またはSMC Networks IZS31の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SMC Networks IZS31の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SMC Networks IZS31の取り付け説明書、サービスマニュアル、簡易説明書、またはSMC Networks IZS31のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SMC Networks IZS31の製品を使用するにあたって最も人気のある説明書を閲覧できます。

SMC Networks IZS31デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSMC Networks IZS31を使用するのを助ける技術的文書のことです。説明書は通常、全てのSMC Networks IZS31ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SMC Networksの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SMC Networks IZS31の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSMC Networks IZS31の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SMC Networks IZS31に関してこのドキュメントで見つけることができる全てのヒントの目次
3. SMC Networks IZS31デバイスの基本機能を使うにあたってのヒント。 SMC Networks IZS31のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SMC Networks IZS31に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSMC Networks IZS31のメーカー/サービスへの連絡先に関する情報。

SMC Networks IZS31についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSMC Networks IZS31の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSMC Networks IZS31で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)