    Operator ’ s Manual CHILLER (“CHILLER” SERIES) Models: CH550 and CH 551 PRINTED IN U.S.A IMI CORNELIUS INC; 1999–2002  IMI CORNELIUS REMCOR INC  500 REGENCY DRIVE  GLENDALE HEIGHTS, IL 60139–2268 T elephone (800) 551–4423 Facsimile (800) 519–4423 Part No. 91272 Revised: August 9, 2002 Revision C THIS DOCUMENT CONT AINS IMPORT ...

  • Cornelius CH 551 - page 2

    i 91272 T ABLE OF CONTENTS Page INTRODUCTION 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICA TIONS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INST ALLA TION INSTRUCTIONS 2 . . . . . . . . . . . . ...

  • Cornelius CH 551 - page 3

    1 91272 INTRODUCTION The REMCOR “ CH ” Series W ater Chillers (Models CH550 – A and CH551 – A) are specifically designed to cool clean water before it is circulated to the cooling application. The Unit includes a complete refrigeration system and associated controls housed in a sturdy sheet metal enclosure with perforated panels for air cir ...

  • Cornelius CH 551 - page 4

    2 91272 INST ALLA TION INSTRUCTIONS LOCA TION Locate the chiller indoors in a well ventilated area with ambient temperatures in the range of 65 ° to 100 ° F . Allow a minimum of six inches of clearance around the chiller for proper air circulation. Avoid hot air discharge from other equipment or enclosed areas where heat could build up and cause ...

  • Cornelius CH 551 - page 5

    3 91272 When the flow rate to the process is critical, a flow meter and valve should be installed in the line in order to ob- tain the proper flow rate. On Units with optional bypass valve, the aforementioned valve can be omitted and the flow can be adjusted with this valve. T urning the valve clockwise increases the flow to the process whereas tur ...

  • Cornelius CH 551 - page 6

    4 91272 3. Remove the screw securing the mounting bracket to the back of the thermostat. 4. Remove the thermostat from the front panel. 5. Install the new thermostat in the front panel and secure it with the mounting bracket. 6. Reconnect the wires at back of the thermostat. 7. Install the wrapper . REPLACING ELECTRONIC DIFFERENTIAL THERMOST A T 1. ...

  • Cornelius CH 551 - page 7

    5 91272 FLUID RECOMMENDA TION Remcor Chillers are designed to operate with water to provide maximum performance for temperatures of 40  F – 100  F. Distilled W ater Acceptable De – Ionized W ater (1 – 5 MEG/OHMS) Acceptable De – Ionized W ater (5+MEG/OHMS) Acceptable with Stainless Steel & PVC only *No Copper or Brass Propylene Gl ...

  • Cornelius CH 551 - page 8

    6 91272 TROUBLESHOOTING GUIDE T rouble Probable Cause Remedy CHILLER DOES NOT OPERA TE A. No power . A. Check fuse or circuit breaker . B. Loose or poor wire connection. B. Check wiring. Correct for loose or poor wire connection. C. Inoperable ON – OFF switch. C. Replace ON – OFF switch. D. Overload device open. D. Allow compressor to cool, the ...

  • Cornelius CH 551 - page 9

    7 620909701 P ARTS LIST FIGURE 1. CH550 AND CH551 EXPLODED VIEW Item No. Part No. Name 1 31934 Switch, Illuminated (CH550) 31935 Switch, Illuminated (CH551) 2 32386 Thermostat, Eliwell No. EWPC902 3 620603708 Blade, Fan 4 62060371 1 Motor , Fan (CH550) 620603709 Motor , Fan (CH551) 5 * Condenser 6 Not Used 7 620603701 Compressor (CH550) 620603702 C ...

  • Cornelius CH 551 - page 10

    ...

  • Cornelius CH 551 - page 11

    8 91272 W ARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship un- der normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or W ilshire prod- uct, in your country , please write, fax or telephone the IMI Cornelius office nearest you. Please provide the ...

  • Cornelius CH 551 - page 12

    CORPORA TE HEADQUARTERS: Remcor Incorporated 500 Regency Drive Glendale Heights, IL 60139 ...

メーカー Cornelius カテゴリー Refrigerator

Cornelius CH 551のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- CH 551の取扱説明書
- Corneliusの製品カード
- パンフレット
- またはCornelius CH 551の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Cornelius CH 551の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Cornelius CH 551の取り付け説明書、サービスマニュアル、簡易説明書、またはCornelius CH 551のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Cornelius CH 551の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Cornelius CH 551デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがCornelius CH 551を使用するのを助ける技術的文書のことです。説明書は通常、全てのCornelius CH 551ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Corneliusの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Cornelius CH 551の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははCornelius CH 551の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Cornelius CH 551に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Cornelius CH 551デバイスの基本機能を使うにあたってのヒント。 Cornelius CH 551のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Cornelius CH 551に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるCornelius CH 551のメーカー/サービスへの連絡先に関する情報。

Cornelius CH 551についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもCornelius CH 551の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがCornelius CH 551で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)