Omega DPG5000の取扱説明書

12ページ 0.86 mb
ダウンロード

ページに移動 of 12

Summary
  • Omega DPG5000 - page 1

    DPG5000 PRESSURE GAUGES M3366/0606 User’ s Guide http://www .omega.com e-mail: info@omega.com ...

  • Omega DPG5000 - page 2

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Contr ol? OMEGA...Of Course! TEMPERA TURE ✓ Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies ✓ W ire: Thermocouple, R TD & Thermistor ✓ Calibrators & Ice Point References ✓ Recorders, Controllers & Process Monitors ✓ Infrared Pyromet ...

  • Omega DPG5000 - page 3

    T able of Contents W arranty/Disclaimer ........................................................................2 Return Requests/Inquiries ................................................................3 Instructions ......................................................................................4 Zer o T rimming ........................... ...

  • Omega DPG5000 - page 4

    • W arranty/Disclaimer OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’ s W arranty adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OMEGA ’ s cu ...

  • Omega DPG5000 - page 5

    • Return Requests/Inquiries Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBT AIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA ’S CUSTOMER SER VICE DEP AR TMENT (IN ORDER T O A VOID PROCESSING DELA YS). The assigned AR number should then be mar ...

  • Omega DPG5000 - page 6

    • Instructions NO TE: All units ar e factory calibrated prior to shipment. 1. Zero T rimming NO TE: Some units are equipped with zer o “knob”. If it becomes necessary to re-adjust the “Zero” on the display , this can be accomplished by turning the trimpot marked “Z” just to the left of the On/Off push button. On the DPG5000 there is e ...

  • Omega DPG5000 - page 7

    4. Re-Calibration This procedure requires a known pressure source of at least ±0.1% accuracy in order to fully utilize the accuracy potential of the DPG5000 (If not available, the gauge can be returned to OMEGA for re-calibration.) Pr ocedure: A. Ensure the Gauge is at 0 psig (or vacuum if absolute), and adjust the zero as per instructions in step ...

  • Omega DPG5000 - page 8

    7. 4-20 mA T ransmitter Option When equipped with this option the gauge no longer operates from batteries but instead is “Loop Powered”. The loop connection is made to a 6 pin receptacle located at the rear of the unit (a mating plug is supplied). A voltage of between 9 and 32 VDC must be maintained at this connection (Pin A is “+” and Pin ...

  • Omega DPG5000 - page 9

    A F B E C D 6 Pin Connector 8. External Power (24 VDC) and 0 to 5 VDC Analog Output Option When equipped with this option the gauge no longer operates from batteries but instead is “externally powered”. Both the 24* VDC input power and the 0 to 5 VDC Analog Output are connected to the 6 pin circular connector on the rear of the unit. Pin connec ...

  • Omega DPG5000 - page 10

    DPG5000 M3366/0606 Notes 8 ...

  • Omega DPG5000 - page 11

    OMEGA ’ s policy is to make running changes, not model changes, whenever an improvement is possible. This af fords our customers the latest in technology and engineering. It is the policy of OMEGA to comply with all worldwide safety and EMC/ EMI regulations that apply . OMEGA is constantly pursuing certification of its products to the European N ...

  • Omega DPG5000 - page 12

    OMEGAnet ® On-Line Service Internet e-mail www .omega.com info@omega.com Servicing Nor th America: USA: One Omega Drive, P .O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 F AX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 F AX: (514) 856-6886 e-mail: info@omega.ca ...

メーカー Omega カテゴリー Marine Instruments

Omega DPG5000のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- DPG5000の取扱説明書
- Omegaの製品カード
- パンフレット
- またはOmega DPG5000の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Omega DPG5000の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Omega DPG5000の取り付け説明書、サービスマニュアル、簡易説明書、またはOmega DPG5000のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Omega DPG5000の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Omega DPG5000デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがOmega DPG5000を使用するのを助ける技術的文書のことです。説明書は通常、全てのOmega DPG5000ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Omegaの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Omega DPG5000の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははOmega DPG5000の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Omega DPG5000に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Omega DPG5000デバイスの基本機能を使うにあたってのヒント。 Omega DPG5000のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Omega DPG5000に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるOmega DPG5000のメーカー/サービスへの連絡先に関する情報。

Omega DPG5000についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもOmega DPG5000の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがOmega DPG5000で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)