Bryant 677C--Aの取扱説明書

36ページ 3.05 mb
ダウンロード

ページに移動 of 36

Summary
  • Bryant 677C--A - page 1

    1 677C- - - - A PREFERRED t 14 SEER SI NGLE- - P ACKAGED HYBRI D HEA T r DUAL FUEL SYST EM WIT H PURO N r (R - - 410A) REFRIGE RANT SINGLE AND TH REE P HASE 2 - - 5 NO MINAL TONS (SIZES 2 4 - - 60 ) Installation Instructions NOTE : Read the en tire in structio n man u al befo re starting the installatio n . NOTE : I ns ta l le r : Ma ke sur e the O ...

  • Bryant 677C--A - page 2

    2 or d eath . W A RN ING sign ifies h azards w hich cou ld resu lt in per- sona l inj ur y or de a th. CAUTI ON i s use d t o ide nt if y unsa f e pra c ti c - es wh ich may re s ult i n mi nor per s onal i njur y or produc t a nd prop- er t y dama ge. NO TE is us e d t o highli ght s ugges t ions whi c h will result in en h anced in stallatio n, r ...

  • Bryant 677C--A - page 3

    3 A09146 Fig. 2 - - 677C- - - - A24- -30 Unit Di me ns ions 677C - - - - A ...

  • Bryant 677C--A - page 4

    4 A09147 Fig. 3 - - 677C- - - - A36- -60 Unit Di me ns ions 677C - - - - A ...

  • Bryant 677C--A - page 5

    5 C B A F D E L ARGE CURB C B A F D E SMALL CURB ROOF CURB DET AIL Wood nailer* Roofcurb* Insulation (field supplied) *Provided with roofcurb Cant strip field supplied Roofing material field supplied Flashing field supplied HVAC unit base rails Roofcurb Sealing Gasket HVAC unit basepan Anchor screw A09090 A09095 A09110 A09111 UNIT S IZ E CATALO G N ...

  • Bryant 677C--A - page 6

    6 A CCESS P ANELS MUST BE IN PLA CE WHEN RIGGING. P ANNEA UX D'A CCES DOIT ÊTRE EN PLA CE POUR MANIPULA TION. 50CY502286 2.0 CA UTION - NOTICE TO RIGGERS PRUDENCE - AVIS AUX MANIPULATEUR Use top skid as spreader bar. / Utiliser la palette du haut comme barre de répartition SEAL STRIP MUST BE IN PLACE BEFORE PLACING UNIT ON ROOF CURB DUCTS DE ...

  • Bryant 677C--A - page 7

    7 3. Att a ch a cl e vis of suf fi ci e nt str e ngth in t he mi ddle of the st r aps . Adj ust t he c le vi s l oc at i on t o e nsur e unit is l if t ed l e vel wit h the gr ound. After th e un it is placed on the ro of cu rb o r m ounting pad, re move the to p sk id. Ste p 6 — Conne c t Co ndens ate Dr ain NOTE : When installing c ondens at e ...

  • Bryant 677C--A - page 8

    8 OUT TEE NIPPLE CAP IN C99020 Fig . 7 - - Sed imen t T ra p 5. Install an accessib le, extern al, man u al main shu to ff valve in gas supply pi pe wit hi n 6 ft (1. 8 m) of hea t ing s e ct i on. 6. Ins t al l gr ound - - joi nt union cl ose t o he a ti ng sec t ion be t we en unit m anua l s hutof f a nd ext er na l manua l ma i n shut- -off val ...

  • Bryant 677C--A - page 9

    9 T able 1 – Phys i cal Data - - Unit 677C - - - - A UNIT SIZE 24040 24060 30040 30060 36060 36090 42060 42090 NOMINAL CAP ACITY - - - ton 2 2 2 --- 1 / 2 2 --- 1 / 2 3 3 3 --- 1 / 2 3 --- 1 / 2 SHIPPING WEIGHT - - - lb. (kg) 368 167 368 167 378 171 378 171 450 204 450 204 491 223 491 223 COMPRES SORS Scro ll Qu an tity 1 REFRIG ERA NT (R - - - 4 ...

  • Bryant 677C--A - page 10

    10 T able 1 - - Physi cal Data - - Uni t 677C- - - - A Cont ’ d) UNIT S IZE 48090 48115 48130 60090 60115 60130 NOMI NAL C AP AC IT Y - - - t on 444555 SHI PPING WEI GH T - - - lb (kg) 513 233 513 233 513 233 543 246 543 246 546 246 COMP RESSO RS Scroll Quantity 1 RE FRI GE RANT (R - - - 410A) Quantity - - - lb (kg ) 17.0 7.7 17.0 7.7 17.0 7.7 16 ...

  • Bryant 677C--A - page 11

    11 4. All u nits m ust h av e field - - su pp lied f ilters or accesso ry filter rack in stalled in th e retu rn - - air side o f the u n it. Reco mm end ed sizes for filters are sho wn in T able 1. 5. Siz e al l duct work for maxi mum re quir e d ai rf l ow (e it he r hea t ing or cool i ng) for uni t be ing i ns ta l le d. A void a br upt du ct s ...

  • Bryant 677C--A - page 12

    12 mor e t ha n 100 f t (30. 5 m) from t he unit ( a s mea s ure d a long the cont r ol volt a ge wir e s ), us e no. 16 A WG col or- - code d, i nsul a te d (35 _ C m inim um ) wires. Loca t e the s e ve n (ei ght on 3 - - phas e) l ow volt age t he rm ost a t l e ads in 24 volt spl i ce box. Se e Fig. 10 f or conne c ti on di agr a m. Run the low ...

  • Bryant 677C--A - page 13

    13 e. Ensure wi re s do not t ouc h re f ri ge ra nt tubi ng or sha r p sheet m etal edg es. f. In sp ect coil fins. If d amag ed d urin g sh ipp in g and handl i ng, c a re f ull y s tr a ight e n fi ns wi th a fi n c omb. FIRE, EXPLOSI ON HAZARD Fai l ure t o f oll ow t his wa r ning c oul d re s ult i n per sona l i njur y , death o r pro perty ...

  • Bryant 677C--A - page 14

    14 Pipe Plug Manifold A07679 Fig . 11 - - Bu rn er Assemb ly MANIFOLD BURNER BURNER FLAME C99021 Fig . 1 2 - - Mon o po rt Bu rn er Ch eck Heatin g Con tr ol Sta r t a nd c hec k t he unit f or prope r hea t ing c ont rol ope ra t ion a s follo ws (see fu rn ace ligh tin g in structio n s lo cated o n th e insid e of the co n trol access pan el: 1. ...

  • Bryant 677C--A - page 15

    15 REGULA TOR COVER SCREW ADJUSTMENT SCREW REGULA TOR SPRING (PROP ANE - WHITE) NA TURAL - SIL VER) GAS PRESSURE REGULA TOR ADJUSTMENT MANIFOLD PRESSURE T AP INLET PRESSURE T AP ON/OFF SWITCH PLASTIC ( A07751 Fig. 13 - - Si ngle- - Stage Gas V alve If l a r ge r a djus t me nts a r e re qui re d, c ha nge ma in burner or i fi c e s fol l owing the ...

  • Bryant 677C--A - page 16

    16 com pletes th e co ntro l circu it. Th e d irect - - spark ig nitio n sy stem cyc l es and the uni t r e tur ns to nor ma l he a t ing ope r at i on. T a ble 5 – LED Indi c ati ons ST ATUS CO DE LE D INDI CATI ON Norm al Operatio n 2 On No Po wer Hardware F ail ure Off Limit S witch Fault 2 Flas hes Flam e Sen se Fault 3 Flas hes Four Con secu ...

  • Bryant 677C--A - page 17

    17 ELECTRICAL SHOCK HAZARD Fai l ure to fol l ow thi s wa rni ng c ould r e sul t in pe r sona l inj ur y or deat h. Bef or e m aki ng a ny indoor wiri ng a djus t me nts , s hut of f ga s suppl y . Then dis conne c t ele c tr i ca l powe r to the unit a nd ins t al l l ockout t a g befor e c ha nging blow er s pe ed. ! W ARNING This uni t ha s ind ...

  • Bryant 677C--A - page 18

    18 COM LOW HIGH GAS HEA T Q1 R1L C8 RL3 Q3 DCR QCR QC1 G1 G2 A7 D4 D6 C2 OILL R9 AB A15 C4 C9 C0 R4 RL4 C7 R2 R3 R5 R6 QCB Y Y R U C 24VAC JW1 P2 P1 W2 Y2/ Y1/ Y DH GC R SSTZ -8 P3 SDL 24V AC/R CDM/C F1 QC6 QC7 QC4 QC3 K2 K1 D2 RI0 RI2 JM6 RI DL JM5 U1 C3 D3 D5 JW3 JW2 JW4 JW7 3 AMP C A09058 Fig. 14 - - Int er f ace Fan Boar d (I FB) T a ble 7 – ...

  • Bryant 677C--A - page 19

    19 T able 10 – Dr y Coi l A ir Del ive r y* - - Hori zont al and Downfl ow Dis c har ge - - Unit 677C - - - - A24- -60 UNIT HEA T IN G RISE RANGE MOTOR SPEED WIRE COL OR EXTER NAL STATIC PR ES SURE ( in. W .C.) 0.1 0.2 0.3 0.4 0.5 0. 6 0.7 0.8 0.9 677C - - - - - - A24040 30 - 60 o F (17 - 33 o C) Low Blue CFM 741 638 547 415 --- --- --- --- --- H ...

  • Bryant 677C--A - page 20

    20 T able 10 - - Dry Coi l Air De li ve ry* - - Hor iz ont al and Downf l ow Di s char ge - - Uni t 677C - - - - A24- -60 Cont UNIT HEA T IN G RISE RANGE MOTOR SPEED WIRE COL OR EXTER NAL STATIC PR ES SURE ( in. W .C.) 0.1 0.2 0.3 0.4 0.5 0. 6 0.7 0.8 0.9 677C - - - - - - A30060 25 - 55 o F (14 - 31 o C) Low Blue CFM 741 638 547 415 --- --- --- --- ...

  • Bryant 677C--A - page 21

    21 T able 10 - - Dry Coi l Air De li ve ry* - - Hor iz ont al and Downf l ow Di s char ge - - Uni t 677C - - - - A24- -60 Cont UNIT HEA T IN G RISE RANGE MOTOR SPEED WIRE COL OR EXTER NAL STATIC PR ES SURE ( in. W .C.) 0.1 0.2 0.3 0.4 0.5 0. 6 0.7 0.8 0.9 677C - - - - - - A42060 25 - 55 o F (14 - 31 o C) Low 1 Blue CFM 1295 1234 1182 1126 1075 1016 ...

  • Bryant 677C--A - page 22

    22 T able 10 - - Dry Coi l Air De li ve ry* - - Hor iz ont al and Downf l ow Di s char ge - - Uni t 677C - - - - A24- -60 Cont UNIT HEA T IN G RISE RANGE MOTOR SPEED WIRE COL OR EXTER NAL STATIC PR ES SURE ( in. W .C.) 0.1 0.2 0.3 0.4 0.5 0. 6 0.7 0.8 0.9 677C - - - - - - A48115 30 - 60 o F (17 - 33 o C) Low Blue CFM 1445 1389 1341 1281 1236 1189 1 ...

  • Bryant 677C--A - page 23

    23 T able 10 - - Dry Coi l Air De li ve ry* - - Hor iz ont al and Downf l ow Di s char ge - - Uni t 677C - - - - A24- -60 Cont UNIT HEA T IN G RISE RANGE MOTOR SPEED WIRE COL OR EXTER NAL STATIC PR ES SURE ( in. W .C.) 0.1 0.2 0.3 0.4 0.5 0. 6 0.7 0.8 0.9 677C - - - - - - A60115 30 - 60 o F (17 - 33 o C) Low Blue CFM 1448 1362 1296 1226 1168 1108 1 ...

  • Bryant 677C--A - page 24

    24 A09068 Fig. 15 - - 208/230- -1 - - 60 W ir i ng Diagr am, Uni t 677C- - - - A 677C - - - - A ...

  • Bryant 677C--A - page 25

    25 A09209 Fig. 16 - - 208/230- -3 - - 60 W ir i ng Diagr am, Uni t 677C- - - - A 677C - - - - A ...

  • Bryant 677C--A - page 26

    26 50VT500173 REV 4.0 A09099 Fig. 17 - - Cooling C hargi ng T able- - Subcool ing 677C - - - - A ...

  • Bryant 677C--A - page 27

    27 MAINTENANCE T o ensur e cont inui ng high pe r f orma nc e and to m ini mi z e the po ssib ility o f p rematu re equ ip men t failu re, perio d ic main tenan ce mu st be perform ed o n th is equ ip men t. T h is com bin atio n hea t ing/ c ooli ng uni t shoul d be ins pec t ed a t le a s t onc e each year b y a qual i fi e d ser vi ce pe r s on. ...

  • Bryant 677C--A - page 28

    28 Integrated Gas Unit Controller (IGC) Induced Draft Motor Rollout Switch Mounting Screw Burner Rack Inducer Blower Housing Flue Collector Box Interface Fan Board (IFB) Auto T ransformer fuses used on 460 volt units only . (Hidden) Fan P artition Mounting Bracket A09199 Fig. 18 - - Bl owe r Housi ng and Flue Col le c tor Box Compressor Access Pane ...

  • Bryant 677C--A - page 29

    29 BLOWER HOUSING 2 SETSCREWS (HIDDEN) C99085 Fig. 20 - - Re moval of Mot or and Blowe r Whe e l A07680 Fig. 21 - - Bur ne r Rack Re move d FEEDER TUBE STUB TUBE DEFROST THERMOST A T C99029 Fig. 22 - - Defr ost The r mos tat Loc at ion Outdoor Fan UNIT OPERA TION HAZARD Failu re to follow th is caution m ay result in dam age to u n it com ponent s ...

  • Bryant 677C--A - page 30

    30 If no re f ri ge ra nt le aks a re f ound a nd low c ooli ng perf or ma nce is susp ected , refer to the Check in g and A dju stin g Refrig erant Charge se c ti on. Gas Input The gas i nput doe s not r e quir e c he cki ng unl es s i mpr oper hea ti ng perfo rman ce is su spected . If a pro blem ex ists, refer to th e Start - - U p se c ti on. I ...

  • Bryant 677C--A - page 31

    31 Hig h - - P ressure Switch Th e h igh - - pressu re switch is lo cated in the d isch arge lin e an d prot e ct s a ga ins t e xce s s ive c onde ns er c oi l pre s sur e . It opens at 650 psi g. High pr e s sur e ma y be c a use d by a di r ty outdoor c oil , fa i le d f a n mot or , or out door ai r r ec i rc ul at i on. T o chec k swi t ch: 1. ...

  • Bryant 677C--A - page 32

    32 COMPRESSOR ACCUMULATOR OUTDOOR COIL INDOOR COIL LCS LEGEND HPS – High Pressure Switch LCS – Loss of Charge Switch Accurater ® Meter ing De vice Arro w indicates direction of flo w TXV in Metering Position Bypass P osition HP S C03011 Fig. 25 - - T ypical H eat Pum p Oper ati on, Cool ing Mode COMPRESSOR ACCUMULATOR OUTDOOR COIL INDOOR COIL ...

  • Bryant 677C--A - page 33

    33 re pl ac i ng ref r ige r a nt compone nt s suc h as f ilter d rier, pressure switch , meterin g d ev ice, coil, accu mu lato r , o r reversin g v alv e. Synthe t ic Roof Pr ec auti onary Pr oc e dur e 1. Cover e xt ende d roof wor ki ng ar ea w it h an impe r me abl e polye t hyle ne ( pla s ti c ) dri p cl oth or ta r p. Cover a n appr oxi ma ...

  • Bryant 677C--A - page 34

    34 T able 1 1 – T r ouble s hooti ng Gui de - - Cooli ng or He at Pump Heat ing M ode SYMPTOM CAUS E REM EDY Compr essor a nd Ou tdoor f a n wil l not star t. Po w e r Fa i l u r e Cal l power co mpan y . Fuse blown o r circu it breake r tripped R e p l a c ef u s eo rr e s e tc i r c u i tb r e a k e r . Def ective th ermo stat, con tactor , tra ...

  • Bryant 677C--A - page 35

    35 T able 12 – T r ouble s hooti ng Gui de–H eat ing SYMPTOM CAUSE REMEDY Burners will n ot ign ite W ater in gas line Drain. Ins tall drip leg. No power to fur nace Check power s upply fuses , wiring or c ircuit break er . No 24 - - v power s upply to contr ol circ uit Check tr ansfor mer . NOT E: Some transformer s hav e internal over - - c u ...

  • Bryant 677C--A - page 36

    36 ST AR T - - UP CHECKLIST (Re move and Stor e i n Job Fil e s) I. PRELI MI NARY INFORM A TION MODEL NO.: SERIAL NO. : DA TE: TECHNICI AN: II. PRE ST ART - - U P (In sert check ma rk in bo x a s each item is comp leted) ( ) VERIFY THA T ALL P ACKING MA TERIALS HA VE BEEN REMOVED FROM UNIT ( ) REMOVE ALL SHIPPING HOLD DOW N BOL TS AND BRACKETS PER ...

メーカー Bryant カテゴリー Air Conditioner

Bryant 677C--Aのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 677C--Aの取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant 677C--Aの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant 677C--Aの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant 677C--Aの取り付け説明書、サービスマニュアル、簡易説明書、またはBryant 677C--Aのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant 677C--Aの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant 677C--Aデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant 677C--Aを使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant 677C--Aユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant 677C--Aの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant 677C--Aの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant 677C--Aに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant 677C--Aデバイスの基本機能を使うにあたってのヒント。 Bryant 677C--Aのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant 677C--Aに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant 677C--Aのメーカー/サービスへの連絡先に関する情報。

Bryant 677C--Aについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant 677C--Aの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant 677C--Aで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)