Whistler 800 WATT POWER INVERTERの取扱説明書

15ページ 0.16 mb
ダウンロード

ページに移動 of 15

Summary
  • Whistler 800 WATT POWER INVERTER - page 1

    OWNER’S MANUAL 800 W A TT POWER INVERTER THE WHISTLER GROUP , INC CORPORA TE HEADQUARTERS 13016 N. W alton Blvd. Bentonville, AR 72712 TEL (479) 273-6012 F AX (479) 273-2927 www .whistlergr oup.com CUSTOMER RETURN CENTER 1201 N. Dixieland Rd. Rogers, AR 72756 Consumer Relations T el (800) 531-0004 Email: info@whistlergr oup.com P/N 205563 © 2004 ...

  • Whistler 800 WATT POWER INVERTER - page 2

    1 If you have questions concerning the operation of this Whistler product please call consumer relations: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT Please keep the receipt in a safe place. Y ou may r egister your product online at www .whistlergr oup.com. If the unit is returned without a dated pr oof of pur- chase, an out of warra ...

  • Whistler 800 WATT POWER INVERTER - page 3

    A Wor d About WHISTLER Inverters. Whistler inverters convert low voltage, direct curr ent (DC) to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “T echnical Operating Principles” section for more information. Depending on the model and its rated capacity , Whistler inverters draw power either ...

  • Whistler 800 WATT POWER INVERTER - page 4

    INVERTER BASICS Getting Started Power equipment and appliances which operate with motors or tubes requir e an initial surge of power to get them up and running. This power surge is r eferred to as the "starting load" or "peak load." (By comparison, electrical devices such as standard light bulbs do not r equire a lar ge starting ...

  • Whistler 800 WATT POWER INVERTER - page 5

    INVERTER BASICS Don’t Push It. Although your Whi stle r inverter has the capacity to provide power output (excess current) equal to appr oximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maximum continuous wattage rat ...

  • Whistler 800 WATT POWER INVERTER - page 6

    OPERA TION Making the Connection. This inverter is designed to connect to your 12 volt battery by the supplied #8 gauge cables. 1. Make certain that the inverter’ s rocker switch is in the OFF (O) position. 2. Connect the cables to the power input terminals at the rear of the inverter and tighten the scr ews to make a secure connection. Do not us ...

  • Whistler 800 WATT POWER INVERTER - page 7

    Important Information on Battery Chargers Using your inverter to rechar ge units designed to charge such portable equipment as power tools, flashlights, video cameras and laptop computers may cause damage to the inverter or the charging unit. Check with the appliance manufacturer for compatibility with sine wave inverters if you’re unsur e. Altho ...

  • Whistler 800 WATT POWER INVERTER - page 8

    13 ADDITIONAL FEA TURES Automatic Shut Down & Related Safety Features. Each Whistler inverter model has an unique LED Indicator warning light system which operates in conjunction with the automatic shut down feature . These indicator lights operate as follows: GREEN LED: System ready . RED LED: System overload/automatic shut down. YELLOW LED: O ...

  • Whistler 800 WATT POWER INVERTER - page 9

    2. Low Battery V oltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power sour ce drops below 10.5 volts, an audible tone will be hear d. This is the low battery voltage alarm. b) The inverter will automatically shut down when the input voltage drops below 9.5 volts. This pr otects the battery from completely draining. In t ...

  • Whistler 800 WATT POWER INVERTER - page 10

    17 16 OPERA TING PRINCIPLES OPERA TING PRINCIPLES assume that the measured waveform will be a pur e sine wave. Consequently , these meters will not read the RMS modified sine wave voltage correctly and, when measuring your Wh is tl er inverter output, the meters will read about 20 to 30 volts too low . T o accurately measure the output voltage of y ...

  • Whistler 800 WATT POWER INVERTER - page 11

    OPERA TION SUMMAR Y 19 OPERA TION SUMMAR Y 18 • This inverter is designed to be connected to the power source with the supplied cables or with #4 wir e up to 12’ - #2 wire for longer length. When utilizing the sup- plied cables do not attempt to modify or lengthen them. • Always make certain that the power cable terminal con- nections run Neg ...

  • Whistler 800 WATT POWER INVERTER - page 12

    21 20 TROUBLESHOOTING TROUBLESHOOTING PROBLEM: Low Battery Alarm On All The Time Problem Solution Input voltage below Keep input voltage above 10.5 volts. 10.5 volts to maintain regulation. Poor or weak battery Replace battery . condition. Inadequate power being Use lower gauge wire. delivered to the inverter or excessive voltage drop. Red LED On P ...

  • Whistler 800 WATT POWER INVERTER - page 13

    SPECIFICA TIONS 23 22 TROUBLESHOOTING WHISTLER 800 WA TT INVERTER SPECIFICA TIONS Maximum Continuous Power .....................800 Watts Maximum Surge Capability (Peak Power) 1600 W atts No Load Current Draw ....................................<0.40 A W aveform ....................................Modified Sine W ave Operating Input V oltage Ran ...

  • Whistler 800 WATT POWER INVERTER - page 14

    W ARRANTY IMPORT ANT : Whistler will not assume responsibility for loss or damage incurred in shipping. Ther efore, please ship your inverter insured with r eturn receipt requested. 2. Include with your unit the following information, clearly printed: • Y our name and street addr ess (for shipping via UPS), a daytime telephone number , (No P .O. ...

  • Whistler 800 WATT POWER INVERTER - page 15

    W ARRANTY Service Out Of W arranty Inverters will be repair ed at “out of warranty” service rates when: • The unit’ s original warranty has expired. • Dated store receipt is not supplied. • The unit has been returned without its serial number . • The unit has been abused, modified, installed improperly , or had its housing removed. Th ...

メーカー Whistler カテゴリー Power Supply

Whistler 800 WATT POWER INVERTERのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 800 WATT POWER INVERTERの取扱説明書
- Whistlerの製品カード
- パンフレット
- またはWhistler 800 WATT POWER INVERTERの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Whistler 800 WATT POWER INVERTERの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Whistler 800 WATT POWER INVERTERの取り付け説明書、サービスマニュアル、簡易説明書、またはWhistler 800 WATT POWER INVERTERのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Whistler 800 WATT POWER INVERTERの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Whistler 800 WATT POWER INVERTERデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがWhistler 800 WATT POWER INVERTERを使用するのを助ける技術的文書のことです。説明書は通常、全てのWhistler 800 WATT POWER INVERTERユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Whistlerの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Whistler 800 WATT POWER INVERTERの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははWhistler 800 WATT POWER INVERTERの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Whistler 800 WATT POWER INVERTERに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Whistler 800 WATT POWER INVERTERデバイスの基本機能を使うにあたってのヒント。 Whistler 800 WATT POWER INVERTERのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Whistler 800 WATT POWER INVERTERに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるWhistler 800 WATT POWER INVERTERのメーカー/サービスへの連絡先に関する情報。

Whistler 800 WATT POWER INVERTERについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもWhistler 800 WATT POWER INVERTERの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがWhistler 800 WATT POWER INVERTERで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)